TrackNet TABS TBDW100-915 Reference Manual

Specifications

Brand: TrackNet
Category: Kitchen Appliances
Model: TABS TBDW100-915 (Reference Manual)
File Type: PDF
File Size: —
Pages: 6

Read Online

Read the TrackNet TABS TBDW100-915 Reference Manual online using the built-in PDF viewer.

Text of the manual

© 2017 TrackNet Inc, USA and Trackio GmbH, Switzerland. All rights reserved.

Table of Contents 1. Description.................................................1 2. Specifications............................................2 2.1 Mechanical..........................................2 2.1.1 Sensor.............................................. 2 2.1.2 Magnet............................................ 2 3. Operation...................................................3 3.1 Power On Reset ................................3 3.2 Transport Mode ...............................3 3.3 Installation Mode .............................3 3.4 Default Operation.............................3 4. Messages...................................................4 4.1 Status...................................................4 4.1.1 Common Fields.............................. 4 4.1.2 Triggers........................................... 4 4.1.3 Payload........................................... 4 4.2 Command..........................................5 1. Description The Tabs Door & Window sensor utilizes LoRaWAN connectivity to communicate the proximity or not of a magnet. The intended use is to place the sensor and magnet on separate elements of a door or window to determine if the door or window is open or closed. The sensor is composed of two parts. The main body contains the active electronics to measure magnetic fields and transmit any changes to a LoRaWAN network. The second part is a permanent magnet of sufficient field strength to be detected by the Hall Effect sensor on the main body.

© 2017 TrackNet Inc, USA and Trackio GmbH, Switzerland. All rights reserved.

2. Specifications 2.1 Mechanical 2.1.1 Sensor Length x Width x Height 50mm x 20mm x 50mm Weight 30g without battery 40g with battery 2.1.2 Magnet Length x Width x Height 31mm x 20mm x 20mm Weight 12g 2.2 Environmental Temperature -20°C to +50°C IP Rating IP 50 equivalent 2.3 Radio Frequency Either 863–870MHz for EU models and 902–928MHz for North America Tx Power +19dBm conducted Rx Sensitivity (Conducted) -140dBm Antenna Gain -2dBi Peak, -5dBi Avg 2.5 Power Source 3.6V ½ AA Li-SOCl2 1200mAh battery Maximum Voltage 3.6V Minimum Voltage 3.1V Current 135mA maximum/5uA minimum 2.6 User Interface LEDs One blue LED Sensor Hall Effect 14 Gauss trigger typical 2.4 Certifications and Conformity FCC ID: 2AMUGTBSP100 IC: 22980-TBSP100 CE ROHS REACH 2.7 Additional Features PCB Temperature Battery Monitoring

© 2017 TrackNet Inc, USA and Trackio GmbH, Switzerland. All rights reserved.

3. Operation 3.1 Power On Reset Anytime the device power drops below 2.8V the device will enter a Power On Reset (POR) when greater than 2.8V is restored. After a POR the device will wait up to 30 seconds before entering default operation. 3.2 Transport Mode They are shipped with a plastic battery isolation tab that must be removed to enable operation. 3.3 Installation Mode The device shall enter installation mode after being commanded by the network and remain in installation mode for 3 minutes. While in installation mode the device will flash the LED 3 times within 500ms for every transition between sensing states, i.e. whenever the device detects changes between open and closed. 3.4 Default Operation While in default operation the device will immediately send a message any time there is a transition from Open to Close or vice-versa. Additionally, the device will send a message anytime it has been inactive for 6 hours.

© 2017 TrackNet Inc, USA and Trackio GmbH, Switzerland. All rights reserved.

4. Messages LoRaWAN Packets for this device use port 100. 4.1 Status 4.1.1 Common Fields Status[7:0] {Fault3, Fault2, LED1, LED0, Fault1, Fault0, BTN1, BTN0} • Nominally Fault0 indicates no network time available • Nominally Fault1 indicates loss of primary sensor function • Nominally Fault2 indicates loss of secondary sensor function • Nominally Fault3 indicates loss of network connectivity Battery[7:0] LoRaWAN Decode • 0 => Device is charging or line powered • 1 to 254 => device level, 1 = minimum and 254 = fully charged • Futher encode • [7:4] = predicted battery life percentage, 15 = New, 0 = Replace • [3:0] = BatteryVoltage — 2.5V, in 0.1V steps, So 3.1V = 6 • 255 => Device could not measure battery — possible Fault Temperature[6:0] Unsigned Integer (0 to 127) Temperature = value - 32, measurement range -32° to 95°C 4.1.2 Triggers Packet Triggers: 360 minute inactivity, Switch Open, Switch Close 4.1.3 Payload Port 100 Payload Length 8 bytes Byte 0 1 2 3 4 5 6 7 Field Status Battery Temp Time Count

© 2017 TrackNet Inc, USA and Trackio GmbH, Switzerland. All rights reserved.

Status Sensor status Bit [0] 1 – open, 0 – closed Bits [7:1] RFU Battery Battery level Bits [3:0] unsigned value ν, range 1 – 14; battery voltage in V = (25 + ν) ÷ 10. Bits [7:4] unsigned value κ, range 0 – 15; remaining battery capacity in % = 100 × (κ ÷ 15). Temp Temperature as measured by on-board NTC Bits [6:0] unsigned value τ, range 0 – 127; temperature in °C = τ - 32. Bit [7] RFU Time Time elapsed since last event trigger Bits [15:0] unsigned value in minutes, range 0 – 65,535. Count Total count of event triggers Bits [23:0] unsigned value, range 0 – 16,777,215. Note: This value is not stored persistently on the device, and may reset whenever the device is power-cycled or rebooted. 4.2 Command 4.1.3 Payload (cont.) RESERVED.