THORLABS OTKB Manual 

Text of THORLABS OTKB Manual 

Optical Trap Kit

19590-D04-V15; Apr 12, 2012 Page 2 www.thorlabs.com Table of Contents 1. Safety ............................................................................................................................................3 2. Introduction ..................................................................................................................................4 3. Setup Description and Segments .......................................

Optical Trap Kit

19590-D04-V15; Apr 12, 2012 Page 3 www.thorlabs.com Part 1. Safety All statements regarding safety of operation and technical data in this instruction manual will only apply when the unit is operated correctly. WARNING This unit must not be operated in explosive environments WARNING Make sure the fuse setting at the back of the laser diode driver and temperature controller are appropriate for your region. Failure to do this will result in

Optical Trap Kit

19590-D04-V15; Apr 12, 2012 Page 4 www.thorlabs.com Part 2. Introduction In 2007, three researchers in the Department of Biological Engineering at MIT – Steve Wasserman, David Appleyard, and Matthew Lang – built an optical trapping setup for use in teaching labs. Their results were published in the American Journal of Physics [S. Wasserman, D. Appleyard, and M. Lang, Optical Trapping for Undergraduates, Am. J. Phys. 75, (2007)]. Based

Optical Trap Kit

19590-D04-V15; Apr 12, 2012 Page 5 www.thorlabs.com Figure 5.1: The Collimator Segment 3.2 The Beam Expander Segment: This includes the beam expansion achromatic doublets and the cube assembly (with the dichroic) for reflecting the trap laser and transmitting the visible spectrum for camera viewing. It also includes the imaging lens for the camera. The Collimator segment, the Camera segment and the Vertical segment all connect to this at i

Optical Trap Kit

19590-D04-V15; Apr 12, 2012 Page 6 www.thorlabs.com 3.3 The Vertical Segment This segment holds the objective, condenser and light source as could be seen in Figure 5.3. To mount this segment, first remove the top part of whole assembly by unlocking the two screws that connect this to the vertical post. Next, release the screw attaching the lower C1500 to the vertical post and adjust its height until the four ER1.5 rods can slide into the

Optical Trap Kit

19590-D04-V15; Apr 12, 2012 Page 7 www.thorlabs.com 3.4 The Stage Assembly The stage assembly parts ship in their separate boxes and will have to be assembled as described in Section 6.8. 3.5 The Camera Segment This segment mainly has the CCD camera for live imaging. The imaging lens is already connected to the camera port on the cube, C6W. To complete this segment, just slide the four ER1 rods into the four cage rod holes on the C6W, such

Optical Trap Kit

19590-D04-V15; Apr 12, 2012 Page 8 www.thorlabs.com Part 4. Optical Trapping Kit OTKB(OTKB/M) Components This section provides some technical details on the individual components used to build this system. Like many optical trapping systems, this one is based on an inverted microscope design. The structure of the inverted light microscope is constructed using Thorlabs‟ 60mm cage system, which is supported by a damped 1.5″ post (Item

THORLABS Laboratory Equipment Owners Instructions: