P/N 5004-0844 Rev C

October 16, 1985 Equipment Serial No. ----- Shipping Date -------- TECHNICAL MANUAL FOR MODEL 844 FM MODULATION AND STEREO MONITOR T F T Inc. 3090 Oakmead Village Drive Santa Clara, CA 95051 (408) 727-7272 TWX 910-338-0584

TABLE OF CONTENTS

GENERAL INFORMATION 1.1 1.2 1. 3 1. 3 .1 1. 3.2 1.4 1.5 General Description Specifications Accessory Equipment Model 730A SCA Monitor . Model 804 Remote Metering Panel Warranty .•... Claim for damage in Shipment INSTALLATION 2.1 Unpacking and Inspection . . . . 2.2 Power Requirements . . . . . 2.3 Installation and Connections 2.4 Connection of Accessory Equipment 2.4.1 Connection o

TFT 844 The TFT Model 844 FM Modulation stereo monitor

provides both on-the-air and off-the-air monitoring of FM broadcast stations operating in the frequency range of 88 to 108 MHz. The three meter format allows stereo measurements while monitoring total modulation, Left and Right channels. Push button switches allow monitoring of the following functions on the LEFT/TEST Meter: left C

MODULATION METERS, RIGHT

Right channel modulation MODULATION METER, LEFT/TEST Left channel modulation . Right channel modulation Main channel ..•. L + R • • • • • L - R • • • • Indicates and measures right channel modulation . Indicates and measures left channel Modulation . Same as right modulation meter . Same as total modulation meter • + 0.35 dB, 50 Hz to 15 KHz . + 0.35 dB, 23 KHz to 53 KHz 38 KHz 1 eve

*Balanced audio output level ...

*Balanced audio frequency response ....... . SCA output at rear panel Audio (with de-emphasis) left and right ..... Audio (without de-emphasis) 1 eft and right Pilot carrier (19 KHz). Composite . . Remote meter Connectors Meter output Carrier-failure alarm. optional Absence of modulation a 1 arm. option a 1 • • STEREO SEPARATION AND CROSSTALK Separation L-to-R and R-to-L. Crosstalk (L+R) to (L-

Model 804 Remote Metering Panel

The Model 804 duplicates flasher and meter readings and comes with 50 feet of cable (TFT Part No. 51160-0804) 1.4 Warranty TIME & FREQUENCY TECHNOLOGY, INC., warrants each of the instruments of its manufacture to be produced to meet the specifications delivered to the BUYER; and to be free from defects in material and workmanship and will repair or replace, at its expense, for a period of one

TFT 844 Unpacking and Inspection

Upon receiving the instrument, inspect the packing box and instrument for signs of possible shipping damage. After installation, operate the instrument in accordance with the procedures of Section 3 of this manual. If the instrument is damaged or fails to operate properly, file a claim with the transportation company, or with the insurance company if insured separately. 2.2 Power

TFT Monitor Owners Instructions: