ROW weighing scales operation manual REV: C1, June 2015 ROW weighing scales operation manual
CONTENTS
1. INTRODUCTION………………………………………………………1
2. KEY DESCRIPTIONS………………………………………………1
3. BASIC OPERATION…………………………………………..……2
3.1 Zeroing the display…………………………………………………..2
3.2 Taring…………………………………………………………….……2
4. CHECK-WEIGHING…………………………………………………..3
4.1 About check-weighing………………………………………………3
4.2 Set limits………………………………………………………………4
4.3 Set check weighing mode…………………………………………..4
4.4 Note……………………………………………………………………4
5. ACCUMULATED TOTAL…………………………………………..5
6. ANIMAL SCALE………………………………………………………..6
7. CALIBRATION………………………………………………………..6
8. BATTERY OPERATION………………………………………………7
9. FUNCTION MENU SETTING………………………………………8
ROW weighing scales operation manual REV: C1, June 2015 ROW weighing scales operation manual
9. FUNCTION MENU SETTINGS
*ROW only have F4 parameter.
-8-
1. INTRODUCTION
The ROW series of weighing scales provides an accurate, fast and
versatile series of general purpose indicator with unit conversion and
animal scale functions.
All units include automatic zero tracking, unit conversion, tare, and
an accumulation facility that allows the individual weights to be stored
and recalled as an accumulated total.
Wireless transmission and the distance is farther than 100 meters
2. KEY DESCRIPTIONS
Zero
Set the zero point for all subsequent weighing. The display shows
zero.
A secondary function
, of "Enter" key when setting parameters or
other functions.
Tare
Tares the scale. Stores the current weight in memory as a tare value,
subtracts the tare value from the weight and shows the results. This is
the net weight. Entering a value using the keypad will store that value as
the tare value.
A secondary function , of incrementing the active digit when
setting a value for parameters or other functions.
G/N
Press the key , the scale can to select gross weight or net weight
after you tare a weight.
Secondary function , In the setting mode, this key used to move
active digits right.
M+
To print the results to a PC or printer using the optional RS-232
interface. It also adds the value to the accumulation memory if the
-1-
FUNC
-TION
SUB-
FUNCTION
DESCRIPTION
DEFAULT
VALUE
F0 H-L
SEt Lo
Set a value for the Low
limit.
000.000
SEt HI
Set a value for the High
Limit.
000.000
F1 TOL
TO CLR
Clears the accumulation
memory without printing
the results.
TO P-C
Clear memory and print
the total data
TO PRT
Only print the total data
F2 unt
Sets the displayed unit of
weight. Select kg, g, Lb
or oz.
kilogram,
kg
F3 OFF
CLoCK
Set clock off or on,
CLK of
CLK on
CLK off
bL
Set the backlight to be on,
automatic or off,
EL on, EL Au, EL off
EL Au
bEEP
Set the check weighing
mode
F4 prt
Set the printer mode, see
the technical manual for
details
Prog
Pin
Enter
the
programming
and calibration menus by
entering
the
correct
password. See details in
technical manual.
ROW weighing scales operation manual REV: C1, June 2015 ROW weighing scales operation manual
accumulation function is not automatic.
Secondary function ( C or ) , is to act as a clear key or to
move active digits left when setting values for parameters or other
functions.
UNIT or U
Press this key to select the weight unit.
Secondary function (ESC) , is to return to normal operation when
the scale is in a parameter setting mode.
ON/ OFF
Turn on or off the power.
3. BASIC OPERATION
3.1 Zeroing The Display
You can press the ZERO key at any time to set the zero point from
which all other weighing and counting is measured, within 4% of power
up zero. This will usually only be necessary when the platform is empty.
When the zero point is obtained the display will show the indicator for
zero.
The scale has an automatic rezeroing function to account for minor
drifting or accumulation of material on the platform. However you may
need to press the ZERO key to rezero the scale if small amounts of
weight are shown when the platform is empty.
3.2 Taring
Zero the scale by pressing the ZERO key if necessary. The zero
indicator will be on.
Place a container on the platform, a value for its weight will be
displayed.
-2-
by using the keys PRINT/M+, G/N, TARE to select the required setting.
Enter the selected setting by pressing ZERO, display will be
shown ”load”.
Load the calibration mass weight on the platform and wait few
seconds for display stability.
After the stable indicator on press ZERO, display will be
shown ”pass”.
After the calibration the display will start a self test. Remove the load
from platform during the test. Display will come to weighing mode
automatically.
If display will be shown any error or incorrect value, repeat the
procedure again.
8. BATTERY OPERATION
The weighing scale can be operated from the battery if desired. The
battery life is approximately 35 hours.
When the battery needs charging, the battery symbol will blank. The
scale will still operate for about 1 hours after which it will automatically
switch off to protect the battery.
To charge the battery simply plug into the AC adapter. The scale
does not need to be turned on.
The battery should be charged for 12 hours for full capacity.
In the LCD display has an battery indicator to indicate the status of
battery charging. When the scale is plugged into AC adapter, the
internal battery will be charged. When turn on the indicator, if the
battery indicator is full then the battery has a full charge. If it is half
then the battery is nearly discharged and empty indicates the battery
should be charged. When charge the battery, the indicator will be flicker.
As the battery is used it may fail to hold a full charge. If the battery
life becomes unacceptable then contact your distributor.
-7-
ROW weighing scales operation manual REV: C1, June 2015 ROW weighing scales operation manual
Press weight on platform, after stable, you will hear beep on twice,
you can add or remote weight now, scale will beep on again after stable,
at last, remove all weight on platform, the last weight value will store in
memory
6 Animal Scales
ROW can set as an animal scale when external resolution less than
1/3000, about how to set it, see the technical manual of ROW.
Let the animal on the platform, after some second, if reading data
change not a lot, you can hear beep sound and reading data will be
locked.
In reading data lock mode, if you add/remove big weight, display will
still update and lock new reading data.
7. CALIBRATION
In weighing mode, press UNIT key and PRINT/M+ key
together, ”Fo h-l”. Press TARE continuous until display will be
shown ”prog”. Press ZERO, display will be shown “pin”. Enter the
password. Press G/N, UNIT and ZERO, Display will be shown “P1 ref”,
Press TARE, display will be shown “P2 mod”. Enter the function by
pressing ZERO, display will be shown ”sig ra”, Select option ”sig ra”
or ”dua ra” or ”dua in”. Enter the function by pressing ZERO, display
will be shown “dec”, Press TARE continuous until display will be
shown ”cal”. Enter the function by pressing ZERO, display will be
shown “linear”, Press TARE to select for normal calibration ”Nonlin”.
Enter the function by pressing ZERO, display will be shown
“unload”, Make sure there are no loads on the platform and wait few
seconds for stable indicator on. Enter the function by pressing ZERO,
display will be shown”05.000”. Currently adjustment, If want to change
-6-
Press the TARE key to tare the scale. The weight that was
displayed is stored as the tare value and that value is subtracted from
the display, leaving zero on the display. The "NET" indicator will be on.
As product is added only the weight of the product will be shown. The
scale could be tared a second time if another type of product was to be
added to the first one. Again only the weight that is added after taring will
be displayed.
When the container is removed a negative value will be shown. If
the scale was tared just before removing the container this value is the
gross weight of the container plus all product that was removed. The
zero indicator will also be on because the platform is back to the same
condition it was when the ZERO key was last pressed.
3.3 Weighing a sample
To determine the weight of a sample first tare the empty container
then place the sample in the container. the display will show the weight
and the units of weight currently in use.
4 Check-Weighing
4.1 About check-weighing
Check-weighing is a procedure to cause an alarm to sound when
the weight on the scale meets or exceeds values stored in memory.
The memory holds values for a high limit and a low limit.
Check mode 2:
When check range, the display will show OK and the beeper will
sound when the weight is between the limits.
Check mode 3:
When check range, the display will show OK and the beeper will
sound when the weight is out of the limits.
-3-
4.2 Set limits
ROW weighing scales operation manual REV: C1, June 2015 ROW weighing scales operation manual
Press the UNIT key and M+ key together in the weighing mode, it
will display “F0 H-L”, press ZERO key to enter, use TARE key to select
“SET HI” or “SET LO”, press ZERO key to enter, use G/N key to move
active digit, use TARE key to change value, use UNIT key to clear value.
After you enter the value, press ZERO key to sure, press UNIT key to
escape.
4.3 Set check weighing mode
Press the UNIT key and M+ key together in the weighing mode to
enter setting mode, press TARE until display show “F3 OFF”, press
ZERO key to enter, press TARE key until display show “BEEP”, press
ZERO key to enter, press TARE key to select BP 2(check mode 2), BP3
(check mode 3), BP1(no beep), press ZERO key to sure, press UNIT
key to escape.
4.4 NOTE
The weight must be greater than 20 scale divisions for the
check-weighing to operate.
To disable the Check-Weighing function enter zero into both limits
by pressing the UNIT key and M+ key together in the weighing mode,
then the current limits are shown. then set zero and store the zero
values.
5 Accumulated Total
5.1 Note
The scale can be set to accumulate manually by pressing the M+
key. See the PARAMETERS Section for details of selecting the method
using function "F4 P RT". The accumulation function is only available
when weighing.
Please note before every accumulate operate, scale need return to
-4-
zero, and only press M+ key when stable, when weight less than 20d,
accumulate operate will be invalid.
5.2 Accumulate operate
The weight displayed will be stored in memory when the M+ key is
pressed and the weight is stable.
The display will show "ACC 1" and then the total in memory for 2
seconds before returning to normal. (after do accumulate operate, M+
indicator will turn on) If the optional RS-232 interface is installed the
weight will be output to a printer or PC.
Remove the weight, allowing the scale to return to zero and put a
second weight on. Press the M+ key, the display will show "ACC 2"
and then the new total.
Continue until all weights have been added.
*Note: after you change weighing unit, accumulate value will be clear.
5.3 memory recall
To view the totals in memory press M+ key in zero point (ZERO
indicator on).
5.4 memory clear
To clear the memory, just press UNIT key
5.5 automatically accumulate
At first, you need set scale to auto accumulate mode, Press the
UNIT key and M+ key together in the weighing mode, it will display “F0
H-L”, press TARE key until display show “f4 prt”, press ZERO key to
enter, press TARE key to select “p auto”, press ZERO key to sure, then
you need set baud rate and M+ format, print type.
After you set, AUTO indicator on.
-5-