SICK ReLy HAND1 Operating Instructions Manual
Read Online
Read the SICK ReLy HAND1 Operating Instructions Manual online using the built-in PDF viewer.
ReLy HAND1 Operating Instructions Manual: Key Pages of Document
reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modifica‐ tion, abridgment or translation of this document is prohibited without the express writ‐ ten permission of SICK AG. The trademarks stated in this document are the property of their respective owner. © SICK AG. All rights reserved. Original document This document is an original document ...
5 1.1 Purpose of this document........................................................................ 5 1.2 Scope......................................................................................................... 5 1.3 Target groups and structure of these operating instructions................ 5 1.4 Additional information.............................................................................. 5 1.5 Symbols and document conventions...................................................... 6 2 Safety information................................. ...
21 9 Decommissioning............................................................................. 22 9.1 Protecting the environment...................................................................... 22 10 Technical data. ...
1.1 Purpose of this document These operating instructions contain the information required during the life cycle of the safety relay. These operating instructions must be made available to everyone who works with the safety relay. 1.2 Scope This document only applies to a ReLy safety relay with the following type label entries in the Operating Instructions field: • 8020870 1.3 Target groups and structure of these operating instructions These operating instructions are intended for the following target groups: project devel‐ opers (planners, developers, designers), installers, electricians, safety experts (such as CE authorized ...
• Guide for Safe Machinery Six steps to a safe machine 1.5 Symbols and document conventions The following symbols and conventions are used in this document: Safety notes and other notes DANGER Indicates a situation presenting imminent danger, which will lead to death or serious injuries if not prevented. WARNING Indicates a situation presenting possible danger, which may lead to death or serious injuries if not prevented. CAUTION Indicates a situation presenting possible danger, which may lead to moderate or minor injuries if not prevented. NOTICE Indicates a situation presenting possible danger, w ...
DANGER If the safety component is integrated incorrectly, the dangerous state may be ended to late. b Plan the integration of the safety component in accordance with the machine requirements, see "Project planning", page 11. DANGER Hazard due to lack of effectiveness of the protective device In the case of non-compliance, it is possible that the dangerous state of the machine may not be stopped or not stopped in a timely manner. b Please read this document carefully and make sure that you understand the con‐ tent fully before working with the device. b Follow all safety notes in this document. Improper in ...
The protective device must be configured, installed, connected, commissioned, and ser‐ viced by qualified safety personnel only. Project planning For project planning, a person is considered competent when he/she has expertise and experience in the selection and use of protective devices on machines and is familiar with the relevant technical rules and national work safety regulations. Mechanical mounting, electrical installation, and commissioning For the task, a person is considered qualified when he/she has the expertise and expe‐ rience in the relevant field and is sufficiently familiar with t ...
The safety relay ReLy HAND1 is an electrical switching device with inputs and outputs. The safety capable inputs of the safety relay are connected to 2 control devices. The control devices control the internal relays, which reliably switch the enabling current paths. The enabling current paths close only when the two control devices are actuated within 0.5 s (concurrence monitoring). Actuators with positively guided contacts are connected to the enabling current paths. 3.2 Product characteristics 3.2.1 Device overview PWR OUT 13 23 I1 Y1 14 24 I2 A2 RELY 1 2 3 4 I3 S1 A1 I4 Figure 1: Device overview 1 ...
3.2.4 External device monitoring Permanent external device monitoring can be implemented using external wiring. 3.2.5 Status indicators LEDs PWR OUT 13 23 I1 Y1 14 24 I2 A2 RELY I3 S1 A1 I4 PWR OUT 13 23 I1 Y1 14 24 I2 A2 RELY I4 A1 I3 S1 HAND1 1085346 Figure 2: LEDs The labeled positions are only partially assigned LEDs. The positions and their labeling (except for the upper 2 lines) also show the pin assignment of the terminals on the front connector. Table 1: Safety relay indicators Labeling Color Function PWR Green/Red Voltage supply OUT Green Enabling current paths I1 Green Safety ...
DANGER Failure to comply with manufacturer’s obligations Hazard due to lack of effectiveness of the protective device b Carry out a risk assessment before using the safety relay. b Do not manipulate, open or modify the components of the safety relay. b Make sure the safety relay is only repaired by the manufacturer or by someone authorized by the manufacturer. Improper repair can lead to a loss of the protec‐ tive function. 4.2 Operating entity of the machine DANGER Failure to observe operator obligations Hazard due to lack of effectiveness of the protective device b Changes to the machine and chan ...
Required distance: • Above and below the safety relay: ≥ 50 mm • In front of the safety relay: ≥ 25 mm 4.4 Electrical integration Important information DANGER Hazard due to lack of effectiveness of the protective device In the case of non-compliance, it is possible that the dangerous state of the machine may not be stopped or not stopped in a timely manner. b Ensure the safety relay is supplied with supply voltage in all operating statuses. b Ensure that the supply voltage of the safety relay is not connected via safety sen‐ sors or safety switches in order to switch the enabling cur ...
Application diagnostic output Y1 The signal of the Y1 application diagnostic output changes as soon as the enabling cur‐ rent paths switch. The application diagnostic output is not safe. Table 2: Switching behavior of application diagnostic output Y1 State of enabling current paths State of application diagnostic output Y1 Closed 0 V Open 24 V 4.4.3 External device monitoring (EDM) External device monitoring (EDM) With static external device monitoring, the safety relay tests whether the controlled actuators (contactors) have dropped out when the device is switched on. To use external device monitoring, you must co ...
identify defects as a result of modifications or other influences (e.g., damage or manip‐ ulation). The manufacturer and user must define the type and frequency of the thorough checks on the machine on the basis of the application conditions and the risk assessment. Determination of the thorough checks must be documented in a traceable manner. 4.5.1 Minimum requirements for the regular thorough check The following thorough checks must be carried out at regular intervals: • Thorough check of the housing for damage • Thorough check of the cables for damage • ...
Hazard due to electrical voltage b Make sure that the outputs of the safety relay have no effect on the machine dur‐ ing mounting and electrical installation. b Make sure that the safety relay and the connected components are isolated from all voltage sources during mounting and electrical installation of the device and during mounting/dismantling of the front connector. NOTICE Enclosure rating IP20 only applies if the front connector is mounted. 5.2 Mounting procedure Prerequisites • Mounting is done in accordance with EN 50274 and electrical installation in accordance w ...
1. Press the unlocking mechanism on the upper side of the safety relay towards the back. 2. Loosen safety relay from the mounting rail. 5.4 Device replacement Overview In event of a defect, exchange the device and reuse the front connector with the con‐ nected cables. Approach 1. Disconnect device and the connected components from all voltage sources. 2. Take front connector with connected cables off the defective device: Press the unlocking mechanism of the front connector downwards and pull out the front con‐ nector. 5 MOUNTING 16 O P E R A T I N G I N S T R U C T I O N S | ReLy HAND1 8020872/ZX84/2 ...
3. Remove the defective device. 4. Mount new device. 5. Mount front connector with connected cables to the new device: First mount in the device with bent hook and then engage in the housing. Click 13 16 15 Figure 8: Mounting the front connector ✓ The front connector engages with an audible click. MOUNTING 5 8020872/ZX84/2018-11-15 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy HAND1 17 Subject to change without notice ...
In the case of non-compliance, it is possible that the dangerous state of the machine may not be stopped or not stopped in a timely manner. b Ensure the safety relay is supplied with supply voltage in all operating statuses. b Ensure that the supply voltage of the safety relay is not connected via safety sen‐ sors or safety switches in order to switch the enabling current paths. DANGER Hazard due to unexpected starting of the machine Hazard due to electrical voltage b Make sure that the outputs of the safety relay ...
Table 3: Pin assignment of the terminals Terminal Description 13, 14 1) 2) Enabling current path 23, 24 1) 2) Enabling current path I1 Safety capable input for control device A, normally open I2 Safety capable input for control device A, normally closed I3 Safety capable input for control device B, normally open I4 Safety capable input for control device B, normally closed S1 2) 3) External device monitoring input (EDM) Y1 Application diagnostic output (NC) A1 Voltage supply 24 V DC A2 Voltage supply 0 V DC 1) The enabling current paths must be supplied by the same voltage supply. 2) The enabling cu ...
During commissioning, the machine or the protective device may not yet behave as you have planned. b Make sure that there is no-one in the hazardous area during commissioning. 7.2 Thorough check Requirements for the thorough check during commissioning and in certain situations The device and its application must be thoroughly checked in the following situations: • Before commissioning • After changes to the configuration or the safety function • After changes to the mounting or the electrical installation • After exceptional events, such as after manipulation has been detected, af ...
Relays PDF Instructions
— RELION® 670 SERIES Phasor measurement unit RES670 Version 2.1 ANSI Application manual
D5097S - 5 A SIL 3 NC contact Relay Out Module for NE or F&G/ND Load with open/short circuit diagnostic G.M. International ISM0302-4 5 A SIL 3 NC contact Relay Output Module for NE or F&G/ND Load, with open/short circuit diagnostic DIN-Rail and Termination Boa
1 MMR-HL-001-A230 Montáž, obsluhu a údržbu smí provádět jen osoba s odpovídající elektrotechnickou kvalifikací. Installation, service and maintenance of the electrical equipment may be carried out by an authorized person only. Z00 MONITORING LEVEL R
Trip Unit Installation for 140G-M Montaggio sganciatori Auslöser Montage Assemblage Dèclencheur Montaje Relé 脱扣器安装 DIR 1000479R0501 Version 01 WARNING: To prevent electrical shock, disconnect from power source before installing or servicing. I