SICK GTE2 Flat Operating Instructions Manual
Text of SICK GTE2 Flat Operating Instructions Manual
O P E R A T I N G I N S T R U C T I O N
GTE2 Flat
Miniature photoelectric sensors
de
en
es
fr
it
ja
pt
ru
zh
SICK Product Center Asia Pte. Ltd.
Singapore
www.sick.com.sg
Legal information
This work is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is only
permissible within the limits of the legal determination of Copyright Law. Any modifica‐
tion, abr
General safety notes.........................................................................
5
2
Notes on UL approval........................................................................
5
3
Intended use......................................................................................
5
4
Operating and status indicators......................................................
5
5
Mounting.....................................................
General safety notes
■
Read the operating instructions before commissioning.
■
Connection, mounting, and configuration may only be performed by trained
specialists.
■
2006/42/EC
NO
SAFETY Not a safety component in accordance with the EU Machinery Directive.
■
When commissioning, protect the device from moisture, contamination and
UV radiation (sun light).
■
These operating instructions contain information required during the life cycle of
the
LED indicator green: supply voltage active
2
LED indicator yellow: status of received light beam
5
Mounting
Mount the sensor using a suitable mounting bracket (see the SICK range of acces‐
sories).
Note the sensor's maximum permissible tightening torque of 0.1 Nm.
6
Electrical installation
The sensors must be connected in a voltage-free state (UV = 0 V). The following informa‐
tion must be observed, depending on the connection type:
–
Plug connecti
Table 2: Switching output
PNP
Q
(≤ 50 mA)
+ (L+)
Q
– (M)
+ (L+)
Q
– (M)
Q
(≤ 50 mA)
+ (L+)
Q
– (M)
+ (L+)
Q
– (M)
NPN
Q
(≤ 50 mA)
+ (L+)
Q
– (M)
+ (L+)
Q
– (M)
Q
(≤ 50 mA)
+ (L+)
Q
– (M)
+ (L+)
Q
– (M)
7
Commissioning
1
Alignment
Align sensor on object. Select the position so that the red emitted light beam hits the cen‐
ter of the object. You must ensure that the optical opening (front screen) of the sensor is
completely clear.
E
Figure 2: Alignment
Figure 3: Alignment 2
2
Sensing range
0
Sensing range
1
2
3
Sensing range typ. max.
4
(0.16)
8
(0.31)
12
(0.47)
3
11
15
Distance in mm (inch)
12.5
1.5 2
9
3.5
16
(0.63)
7
6
3.5/4.5
Figure 4: Sensing range 15 mm
0
Sensing range
1
2
3
Sensing range typ. max.
10
(0.39)
5
(0.20)
15
(0.59)
20
(0.79)
25
(0.98)
2
20
30
Distance in mm (inch)
25
1
2
15
3
30
(1.18)
15
11
5
4
Figure 5: Sensing range 30 mm
1
Sensing range on white, 90 % remission
2
LED indicator/fault pattern
Cause
Measures
Sensor is faulty
If the power supply is OK,
replace the sensor
Yellow LED lights up, no object
in the path of the beam
Excessive background remis‐
sion
Check changes to the back‐
ground. Reduce the sensitivity
of the sensor or use sensors
with background suppression
Object is in the path of the
beam, yellow LED does not
light up
Sensitivity is set too low or dis‐
tance between the sensor and
the object is to
2 ... 12.5 mm
2 ... 25 mm
Sensing range max.
1.5 ... 15 mm1)
1 ... 30 mm1)
Light spot diameter/distance
7.5 mm / 10 mm
5.5 mm / 15 mm
Supply voltage UB
DC 10 ... 30 V2)
DC 10 ... 30 V2)
Output current Imax.
≤ 50 mA
≤ 50 mA
Switching frequency
800 Hz3)
800 Hz3)
Max. response time
≤ 0.625 ms4)
≤ 0.625 ms4)
Enclosure rating
IP67
IP67
Protection class
III
III
Circuit protection
A, C, D5)