Omron NA Series Practices Manual
Read Online
Read the Omron NA Series Practices Manual online using the built-in PDF viewer.
Key Pages of Document
Practice Guide IAG Collection for EtherNet/IP™ Monitor NA5-15□101□ NA5-12□101□ V454-E1-01 ...
information. Be sure to obtain the manuals for NA Series Programmable Terminal, read and understand the safety points and other information required for use, and test sufficiently before actual use of the equipment. ...
Thank you for your usage of products of Omron Corporation (“Omron”). Without any special agreements, these terms and conditions shall apply to all transactions regardless of who sells. Definitions of Terms Omron product(s): Omron’s factory automation system devices, general control devices, sensing devices, and electronic/mechanical components. - Catalogues: Any and all catalogues (including “Best Components” ...
- Computer virus and other technically harmful program, and - Unauthorized access. Please conduct the followings by yourself: (i) antivirus software, (ii) data input/output, (iii) lost data recovery, (ⅳ) protections against computer virus that contaminate Omron products or the installed software, and (ⅴ) measures to protect Omron products from unauthorized access. - Omron products are designed and m ...
The warranty described in this Terms and Conditions Agreements is a whole and sole liability for Omron products. There are no other warranties, expressed or implied. Omron and its distributors are not liable for any damages arisen from or relating to Omron products. Export Control Customers of Omron products shall comply with all applicable laws and regulations of other relevant countries regarding security export control, ...
Terms and Conditions Agreements ........................................................ 3 Table of Contents ..................................................................................... 6 1 Related Manuals ............................................................................... 7 2 Precautions ....................................................................................... 8 3 Overview............................. ...
No. Model Title V117 NA5-15W□□□□ NA5-12W□□□□ NA5-9W□□□□ NA5-7W□□□□ Programmable Terminal NA Series Hardware USER’S MANUAL V118 NA5-15W□□□□ NA5-12W□□□□ NA5-9W□□□□ NA5-7W□□□□ Programmable Terminal NA Series Software USER’S MANUAL V119 NA5-15W□□□□ NA5-12W□□□□ NA5-9W□□□□ NA5-7W□□□□ Programmable Terminal NA Series Device Connection USER'S MAN ...
the system, use within the ratings and specified performance, and implement safety measures such as safety circuits to minimize the possibility of an accident. (2) For safe use of the system, obtain the manuals of the component devices of the system and check the information in each manual, including safety precautions, precautions for safe use. (3) It ...
EtherNet/IP network or devices connected with the NA Series HMI. • IAG external specifications • IAG installation on a screen IAG Icon Description EtherNet_IP_NetworkMonitor Monitor for an EtherNet/IP device on a network together with NA DLR_Monitor DLR monitor for DLR Super Visor These IAGs are included in the IAG collection file below. Fil ...
The IAG objects were tested with the system configuration and versions below. PC (Sysmac Studio) Sysmac Studio projects with IAGs Screen Transfer NA Series NX7 Series NX-CSG320 ■Ring Node 1783-ETAP, Rockwell Automation GI-S Series EtherNet/IP NX102 Series NJ Series DLR supporting device CIP Safety on EtherNet/IP devices ■Controller ■Ring Super Visor DLR R-SV ■Ring Node DLR R-N NXR-ILM Series ...
This chapter describes the versions of the IAG library. You must check versions of the items listed in the table below before using the library. Item Description How to Check the Version IAG Collection The distributed IAG collection has library versions. The version can be checked in the Sysmac Studio IAG Collections Manager pop-up. IAG Version of each IAG. It manages specification change, bug correction, and others. The version can ...
5-1 EtherNet/IP NetworkMonitor 5-1-1 Specifications External Specifications Object EtherNet_IP_NetworkMonitor Category EtherNet_IP_Monitor Functions ・ Detects all the EtherNet/IP devices that connected with the same network as NA’s Ethernet Port1/Port2. And displays the models and IP addresses on the EtherNet/IP Screen. ・ You can register a network configuration and compare it with an actual configuration. Registered infor ...
EtherNet/IP Screen EtherNet/IP devices that connected to NA’s Ethernet ports are detected and displayed on this screen. User I/F Specifications No Part Description 1 Group The information of a device is shown. Refer to No. 9 and later for details. 2 DropDown You can select an NA port. Port 1 is selected by default. Devices connected to the selected port are displayed. 3 Button Reads the configuration out. 4 Button Lamp Displa ...
When an error occurs on GS-S Unit, outlined in red. Layout Properties Default Description Position (Left, Up) Set in Property. Size (Width, Height) Set in Property. Filtering Window You can filter the devices to display on the EtherNet/IP screen. Filtering setting is possible using the I/O variable FilterMode. User I/F Specifications No Part Description 1 RadioButton You can select a filter ...
Following to the security settings of NA, register a network configuration when a login is permitted. If a user name is not assigned to the input variable RegisteredUserName, a configuration is registered without displaying this window. User I/F Specifications No Part Description 1 Data Display Authority of a user displ ...
User I/F Specifications No Part Description 1 Data Display Data Lamp Differences between the current network configuration and the registered configuration are displayed. Configurations are compared based on unit model and IP address. 2 Data Display A number of mismatches is displayed. 3 Data Display Page numbers ...
in a screen. Direct input Character string (1 to 127) EtherNet_IP_Networ kMonitor0 Type Object type. Not changeable. - - EtheNet_IPMonitor_ IAG_12inch.EtherNe t_IP_NetworkMonito r Version IAG version - - 1.0.0.0 Publisher IAG publisher - - Omron Promotion Sample Appearance Background Color Background color of a page Item selectio ...
Precautions for Correct Use In the usage described in this document, do not set the In/Out variables CurrentPageName and ExitMonitor and leave them blank to avoid unintended behaviors. Version History IAG version Description IAG collection version 1.0.0.0 First edition Ver1.00 ...
The following IAG event can be detected. Event Description SelectETAP Executed when an ETAP device is selected. SelectGI_S Executed when a GI-Series Unit is selected. SelectNXR_ILM Executed when an NXR- ILM Unit is selected. Animations Basic motions can be defined. Security If a user name has been assigned to the input variable RegisteredUserName at a configuration registration, you are required to login to NA. You must ente ...
Property Assignment This IAG reads and displays the configuration information of an EtherNet/IP device that connected to NA’s Ethernet port. Assign a variable to the following property (Input/ Output) in order to share the IP address information of the EtherNet/IP device pressed on the screen with each device’s detailed information page. Property (Input/Output) Description Data Type SelectDeviceIPAddress IP address o ...