Installation and Setup
The SideBox enclosure can be used with both the
Acuity™ and Carbonite switchers. The SideBoxNet
enclosure is only supported by the Acuity™ switcher
running software version 6.0 or higher.
The SideBoxNet enclosure comes pre-assembled with
a number of modules and includes the SideShotNet,
SideSlideNet, and SideStick. All of these product are
installed and connected to the switcher in the same
way, and only differ
Figure 5: VESA Mounting Holes
Cabling
Depending on whether you have a SideBox or
SideBoxNet, the cabling of your enclosure will be
different.
SideBox Cabling
Each SideBox enclosure has connectors for primary
(PS1), and secondary (PS2) power supply, and two
RJ-45 communications ports (PREV and NEXT).
Figure 6: Cable Connections
Note: A maximum of 14 SideBox enclosures can be daisy-
chained together off of a single External Link Port on Acuity™.
A maximum
Ross SideBox Note: A maximum of 15 SideBoxNet enclosures can be
connected to Acuity™.
SideBox Setup
Acuity™ must be set up to communicate with the
SideBox. Carbonite and Carbonite Black automatically
recognise and will communicate with the SideBox.
Setting Up SideBox with Acuity™
To set up communications between the Acuity™ control
panel and SideBox, you must do the following:
•
Set the External Link port (L2, L3, L4) that you
connected to SideBox to Externa
Ross SideBox To Set an Alarm
The alarm notifies users in DashBoard that a power
supply is failing.
1.
Double-click on the Panel node and click on the
Alarm Enables tab.
2.
Select the alarms that you want to enable.
•
PSU1 Voltage Out of Range — alarm if
power supply 1 is out of the safe acceptable
voltage range
•
PSU2 Voltage Out of Range — alarm if
power supply 2 is out of the safe acceptable
voltage range
To Restore Default Settings
All settings, except for t
Select the panel row that
you want to assign the
SideBoxNet to. The panel
row corresponds to the
SideStick or SideBoxNet in
that the module assigned
to row 1 is numbered 1 in
the menus (SideStick1 for
example). You can only
assign the SideStick to an
internal panel row.
First Fader
Assigns the number, or
position, of the first audio
slider on the SideSlideNet
module. Each audio
module has 8 sliders, so
the first slider on module
1 is 1, th