Installation and Setup

The SideBox enclosure can be used with both the Acuity™ and Carbonite switchers. The SideBoxNet enclosure is only supported by the Acuity™ switcher running software version 6.0 or higher. The SideBoxNet enclosure comes pre-assembled with a number of modules and includes the SideShotNet, SideSlideNet, and SideStick. All of these product are installed and connected to the switcher in the same way, and only differ

Figure 5: VESA Mounting Holes

Cabling Depending on whether you have a SideBox or SideBoxNet, the cabling of your enclosure will be different. SideBox Cabling Each SideBox enclosure has connectors for primary (PS1), and secondary (PS2) power supply, and two RJ-45 communications ports (PREV and NEXT). Figure 6: Cable Connections Note: A maximum of 14 SideBox enclosures can be daisy- chained together off of a single External Link Port on Acuity™. A maximum

Ross SideBox Note: A maximum of 15 SideBoxNet enclosures can be

connected to Acuity™. SideBox Setup Acuity™ must be set up to communicate with the SideBox. Carbonite and Carbonite Black automatically recognise and will communicate with the SideBox. Setting Up SideBox with Acuity™ To set up communications between the Acuity™ control panel and SideBox, you must do the following: • Set the External Link port (L2, L3, L4) that you connected to SideBox to Externa

Ross SideBox To Set an Alarm

The alarm notifies users in DashBoard that a power supply is failing. 1. Double-click on the Panel node and click on the Alarm Enables tab. 2. Select the alarms that you want to enable. • PSU1 Voltage Out of Range — alarm if power supply 1 is out of the safe acceptable voltage range • PSU2 Voltage Out of Range — alarm if power supply 2 is out of the safe acceptable voltage range To Restore Default Settings All settings, except for t

Select the panel row that

you want to assign the SideBoxNet to. The panel row corresponds to the SideStick or SideBoxNet in that the module assigned to row 1 is numbered 1 in the menus (SideStick1 for example). You can only assign the SideStick to an internal panel row. First Fader Assigns the number, or position, of the first audio slider on the SideSlideNet module. Each audio module has 8 sliders, so the first slider on module 1 is 1, th