ring RSU60 Instructions Manual
Text of the manual
The Wireless relay system is a low power radio system, designed to operate with 12 Volt DC
systems. This system allows remote control/relay operation of 8 relay channels. These relay
channels are fused to allow connections to components of various amperage. The maximum
current draw of the system is 60A. The system has been designed to reduce the
⑤Emergency Switch Cover
⑥Emergency Switch
⑦Mini Fuse
⑧Work Status Indicator
⑨Power/Failure/Pairing Indicator
⑩Mounting Hole
Fig 1 RSUCPU, Relay Box
①Button operation LED
②Button(Total of 8 Buttons), each button has a LED for Backlight illumination
③Relay Box Status LED(Total of 8 LED)
④Battery Charge indication LED
⑤Charging Input
⑥Battery Cover
Fig 2 RSURC, Remote Control Fob
①Red Input Positive
②Black Input Negative
③Fuse
④Power Indicator
⑤Angle adjustment screws
⑥Fixed H
3. Connections & Controls
3.1 RSUCPU, Relay Box
1.
For the power feed to the Relay box, a copper cable with a cross sectional diameter of
10mm2 is required. Please ensure this cable length does not exceed 3 meters! The power
feed to the relay box is fused at the input with a 60A fuse, placed in a holder.
2.
System is only rated for 12V DC systems. AC power m
①1.5A, Blade Fused
②3.5A, Blade Fused
③5A, Blade Fused
④20A, Blade Fused
⑤1.5A, Built in self resetting fuse
⑥20A, Blade Fused
⑦5A, Blade Fused
⑧3.5A, Blade Fused
⑨1.5A, Blade Fused
Fig 4 RSUCPU Relay Control Box
3.2 RSUCB, Docking station
The purpose of the docking station two fold. It allows the Remote Control Fob to be placed in a safe
p
3.3 RSURC, Remote Control Fob
The Remote Control Fob, allows control of the individual output channels of the Relay box. The Relay
Box outputs can be switched on or off via the Remote Control Fob. Each push button switch on the
Remote Control Fob allows the user to control one Relay channel on the Relay box. The Remote
Control Fob requires a Lithium Ion AAA
4. Operation of System
Once RSU60 has been installed. System can be operated using the Remote Control Fob. The Remote
Control Fob can be operated when placed in the docking station or out of the docking station (provided
the battery is installed). When a push button on the Remote Control Fob is pressed. The following
items will be observed.
1. LED 1 will Fla