INSTRUCTIONS FOR: VACUUM CLEANERS AND

FRONT MOUNTED SQUEEGEES MODEL: PC455, PC477, PC455AK1, PC477AK1 1. SAFETY INSTRUCTIONS 1.1. ELECTRICAL SAFETY  WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following: You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other connectors for wear or damage. You mu

High powered, lightweight industrial units. Stainless steel drum with dual

filtration system for superior performance. Features safety shut-off for wet operation. Trolleys with swivel bin and two rear locking wheels for easy emptying plus front swivel castors for added manoeuvrability. Foot operation for squeegee adjustment. Supplied with Ø38mm accessory kit, 3.2mtr cable with 3 pin plug, cloth and cartridge filters. PC477 is fitted with

Cleaner will not operate.

Dust comes from the motor cover. Reduced efficiency and increased motor speed/vibration. No power supply. Faulty power cable, switch or motor. Container full of liquid. Filter missing or damaged. Filter clogged. Nozzle, hose or bin inlet blocked. Check supply. Check and repair or replace faulty item. Empty container. Fit or replace. Replace or clean filter. Check nozzle, hose and bin inlet for blockage. 6. TROUBLESHOOTING 5.1 Clea

Sealey Vacuum Cleaner Owners Instructions: