1 General introduction ............................................................................................. 3 2 Working principles ................................................................................................ 5 3 Description of the gauge ........................................................................... ...

1 General introduction

The SRT 5000 is a portable surface roughness tester with high accuracy, simple handling and a stable performance. It is widely applicable for testing surfaces of all kinds of metals and non-metals. By using a high-speed DSP processor for the data processing and calculation, measurement and calculation speed has been improved. T ...

2 Working principles

When the sensor is making a linear uniform motion along the test surface, the contact stylus in perpendicular with the work surface is moving up and down on the work surface. Its motion is converted into electric signals, which are amplified, filtered and transformed into digital signals through A/D. The signals are then processed by t ...

4 Technical parameters

Measurement Parameters: Ra (ISO), Rz (DIN), Rq, Rt Units: µm, µinch Stroke Length (mm): 6 Threshold wavelength (mm): 0.25,0.80,2.50 Measurement Range (µm): Ra: 0.05 ~ 10.0 Rz: 0.1 ~ 50 Accuracy: According to ISO Class 3 Tip arc radius: 10 µm±1 µm Touch needle static force measurement: ≤ 0.0 ...

5 Entry into service

5.1 Measurement preparation Take out the instrument from the case. The sensor protector should be closed as indicated below. Move the switch to the right to open the protector so that the sensor comes out. ...

5.2 Turn on/off

To turn on the device press . The device will turn on being set as adjusted before shut down. In order to turn of the device press . If the device will be left unused for 3 minutes, it will shut down automatically. 5.3 Selecting parameters Before measuring the user should set up following parameters: • Measurement method: Ra, Rz, Rq, Rt a ...

When all parameters are set and the protector is open one

can start measuring. Point the Stylus mark to the measured area and press the start button on the top of the gauge. After hearing a signal, the measurement has been finished and the screen will show the measured value. Note: 1) During the pickups movement, make sure that the tester st ...