© 2020 SafeLine and all the SafeLine products and

accessories are copyrighted by law. GL6 manual GSM gateways SafeLine GL6 v.2.1.1 EN Innovation brought to you from Tyresö Sweden all-guides com ...

SafeLine GL6 v.2.1.1 EN

Power: 230 VAC, 50 Hz, max 9 W Battery: 12 V, 0.8 Ah Inputs: 10-30 VDC, 5 mA optically isolated Antenna connector: SMA (female) Size: 96 x 145 x 58 mm (H x W x D) (without antenna) Weight: 830 g Relay output: 1 A/30 VDC, potential free relay contact output IP code: IP20 Output: 12 VDC maximum output 120 mA continuous, 500 mA max 10 min Output indicator intercom: 12 VDC, max 100 mA Line voltage: 48 VDC USB: USB mini 2.0 Interface b ...

SafeLine GL6 v.2.1.1 EN

Content General information 4 Introduction 5 Overview 5 Wiring diagram 6 Relay output 7 Intercom 8 Network services 9 Activating the SIM card 9 Indication LED 10 GSM field strength 11 Reset button 11 Configuration 12 Configuration with PC 12 SafeLine Pro 12 Operation 17 Troubleshooting 18 Interference/poor sound quality 18 Avoid GSM interference 18 ...

SafeLine GL6 v.2.1.1 EN

This unit was built with state-of- the-art technology and to generally recognised safety related technical standards currently applicable. These installation instructions are to be followed by all people working with the unit, in both installation and maintenance. It is extremely important that these installation instructions are made available at all times to the relevant technicians, engineers or servicing and maintenance person ...

SafeLine GL6 v.2.1.1 EN

Overview Introduction 1. Reset button 2. LED’s 3. Intercom button - press once to activate an intercom call 4. SIM-card holder 5. USB-mini for configuration with SafeLine Pro 6. RJ12 for intercom (comphone) 7. RJ12 for telephone line 8. SMA-antenna connector 9. Terminals (C3: Lift Monitoring System (LMS)/SMS. Programmable input for LMS to send SMS messages to up to 3 different numbers.) 10. GND SafeLine GL6 ...

1 2 3

5 6 7 1 2 4 1 2 +12 V 0 V 230 VAC L 230 VAC N GND SafeLine GL6 v.2.1.1 EN Wiring diagram + Battery - Battery Input Relay 1, NO/NC Input intercom, only NO button Indicator intercom Telephone line out all-guides com ...

SafeLine GL6 v.2.1.1 EN

Relay output There are three ways to configure the relay output (configurable in SL Pro). 1. Battery failure Relay is active when battery test has failed. 2. System failure Relay is active when GL6 has GSM network coverage. Relay deactivates when GSM network is missing for more than 15 seconds or when mains power has been off for more than 15 minutes. 3. Emergency light Relay is activated when there is a mains power fa ...

SafeLine GL6 v.2.1.1 EN

The intercom function can be triggered in two ways: 1. Push button once to activate intercom. 2. Push NO button to activate intercom. Optional external indication of active intercom function can be wired between 12 VDC output and intercom indication output. Use of intercom When an intercom call is generated the GL6 rings up to 16 times, waiting for a phone that is connected to the GL6 to answer. LED3 indicates when a ...

SafeLine GL6 v.2.1.1 EN

The GL6 can only recognize the PIN code if the code is set to “1234”, “0000”, “1111” or if it is deactivated. If set to anything else, the GL6 cannot use the SIM card. If the PIN code is set to “1234”, “0000”or deactivated, the SIM card can be used on any of SafeLine’s GSM products. Setting the PIN code 1. Insert the SIM card in an ordinary phone. In the phone’s security settings, change the PIN to “1234 ...

SafeLine GL6 v.2.1.1 EN

LED 1 indicates the power supply status: Continuous green Mains power supply OK. Flashing red Battery operated, no main power supply. LED 2 indicates battery​ condition: Light off Battery OK. Flashing red Battery check in progress. Continuous red Battery test failure. LED 3 indicates the phone line’s status: Slowly flashing green GSM network OK. Flashing green Call connection in progress. Flashing two times green Connected ha ...

SafeLine GL6 v.2.1.1 EN

Reset button Press for 5 sec Turn off when using battery power Press for 3 sec Check GSM network signal strength Press 3 times Start a battery test manually Press once Cancel battery test Press once Turn on when using battery power Reset * Minimum signal strength for using GSM Interface GSM field strength If the reset button on the unit is pressed for 3 seconds the GSM field strength will be displayed for 5 seco ...

SafeLine GL6 v.2.1.1 EN

Configuration with PC The unit can be configured at the office prior to the installation or on site after installation. The configuration software SafeLine Pro can be downloaded from www.safeline-group.com. Configuration SafeLine Pro Use the latest version of SafeLine Pro. The software can be download from www.safeline-group.com. 1. Call settings • Max call time Here you can choose t ...

SafeLine GL6 v.2.1.1 EN

• RX audio level Received Audio Level: Standard. Increase on the RX level of the receiver by 25%. Increase on the RX level of the receiver by 50%. Increase on the RX level of the receiver by 75%. Increase on the RX level of the receiver by 100%. Note: Large increase may cause voice switching problems. 2. External input for monitoring • Function Here you can set the input to different functions. None: Input 1 is not enabled ...

SafeLine GL6 v.2.1.1 EN

• System failure The output relay is activated when the GL6 has a GSM network. The output relay is deactivated when the GSM network has been lost for more than 15 seconds, or when the power has been off for more than 15 minutes. • Emergency light Relay is activated when there is a main power failure, and switches to battery power. 4. Text message Here you can enter information and specify the destination of the text message ...

SafeLine GL6 v.2.1.1 EN

• LMS input SMS An text message is sent if the LMS input has reached the set value. SMS destination: you can enter up to 3 mobile phone numbers. Message: the limit for the message text is 128 characters maximum. 5. Miscellaneous Resets all input fields to their default value. Puts SafeLine Pro in basic mode execution, empties phone fields etc. 6. Connection Test With a computer directly to GL6. • Alarm type None: no test a ...

SafeLine GL6 v.2.1.1 EN

7. Software / hardware information • Software version Here you can find information about the GL6 software version. • Hardware version Here you can find information about the GL6 hardware version. • Serial number Here you can find the serial number of the GL6. • IMEI number (International Mobile Equipment Identity) The IMEI is used by the GSM and UMTS mobile phones. The IMEI is used by yhe GSM network to identify and ...

SafeLine GL6 v.2.1.1 EN

Use the latest version of SafeLine Pro. The software can be download from www.safeline-group.com. Battery check • Automatic battery test Battery capacity is tested every 7 days. The test takes 15 minutes maximum. If the battery test fails LED2 is activated. An SMS is sent to 3 destinations maximum and with a maximum of 128 characters. • Manual battery test Start battery test by pressing the reset button 3 times. To cancel t ...

SafeLine GL6 v.2.1.1 EN

To avoid GSM interference: Place the unit, the lift emergency telephone and the GSM antenna at least 1500 mm apart. Avoid GSM interference Trouble- shooting No LED’s are lit. • Make sure that the supply voltage is: 230 VAC LED 3 is continuously red. • Make sure that the SIM card is correctly inserted. • Check that the SIM card PIN code is deactivated or that the PIN code is set to ”1234 ...

EU Declaration of Conformity GL6 V3.0

Your partner in lift safety Antennvägen 10, 13548 Tyresö, Sweden +46 (0)8-447 79 32, www.safeline-group.com EU Declaration of Conformity Product: Mobile network emulator Type / model: Safeline GL6 Article no: *GL6, *GL6-4G, *GL6-FC, *GL6-FC-4G Manufacturer: SafeLine Sweden AB Year: 2020 We herewith declare under our sole responsibility as manufacturer that the products referred to above complies with the following EC ...

Industrieterrein 1-8 · 3290 Diest · Belgium

Tel.: +32 (0)13 664 662 · [email protected] Support: +32 (0)4 85 89 08 95 SafeLine Deutschland GmbH Kurzgewannstraße 3 · D-68526 Ladenburg · Germany Tel.: +49 (0) 6203 840 60 03 · [email protected] SafeLine Norway Solbråveien 49 · 1383 Asker · Norway Tel.: +47 94 14 14 49 · [email protected] SafeLine Denmark Vallensbækvej 20A, 2. th · 2605 Brøndby · Denmark Tel.: ...