Marani LPP260A Quick User Manual

Text of the manual

LPP260A Quick User's Guide

Before to install the setup.exe, please make sure that the Net Framework 4.0 is already installed on the PC used. After install the setup.exe and run the app “LPP260A” then the system show the following window and after few seconds the main window Below is introduction for the “Device List”:

: Connect all device

: Disconnect all device : Add device to the List : Remove one or more device from the List : Search Device : Device Name : Connection status of the device, by double clicking this characters, user can switch between “On-line” and “Off-line” mode. Click the icon, you will see below conversation window. Click the preferable connec

The User has the possibility to connect the device via USB or RS485 or TCP/IP

* If the USB is selected, the User must set the number of the COM used to connect the device By the way, using the button “Check” the Sw will scan the Pc ports looking for the potentially connected ones: set on the Com Select window the found Com ports until found the working o

2. use the “PM1/ENTER” encoder for selecting the “Interface Utility” field

3. press the “PM1/ENTER” button, for entering the “Interface Setup” field 4. use the “PM2/ESC” encoder, for selecting the RS485 interface 5. use the “PM3/UTILITY” encoder, for selecting the RS485 interface's ID number 6. after operated the selection, press the

* If the TCP/IP is selected, the User can click the

icon, and select “TCP/IP Mode” in the checkbox as below image suggests, and input the device IP address range: In order to use the TCP/IP connection for remotely controlling the LPP260A, need first set on the unit the communication interface as TCP/IP and assign an IP address to the unit, if not used D

on the Edit window is possible edit all parameters of the Input and output Output channel, save and

load configuration on the sw PC, copy the input channel to another input channel, insert and change a User password in order to lock/unlock the interface, link the channel and see the current version of the firmware and software. On the ALL Edi

Lock: momentary lock of the units' controls. When set, the all parameters cannot be accessed by the

user, but no password is required for setting/resetting the lock itself. Used for avoiding to accidentally modify a setting during a live performance or if the user need to leave the editing session momentarily. Password: this tool is allowing