Midian RD-10 Manual
Text of the manual
10 Input / 10 Output Remote Monitor and Remote Control
Manual Revision: 2010-08-10
Covers Firmware Revisions:
4.0 & Higher
Covers PCB Revisions:
C
1
TABLE OF CONTENTS
Specifications
3
General Information
4
Hardware Installation
5
Operation
6
Product Programming
10
Technical Notes
12
Contact Information
12
2
2 mA each
Relay Current
17 mA each
Audio Inputs
Input Level
400 mVRMS
Input Impedance
470KΩ
Dynamic Range
25 dB
Format
DTMF
SINAD Ratio
9 dB
Band Width
2.5%
Twist
10 dB
Audio Outputs
PTT Output Current
200 mA
Audio Output Level
1V RMS
Audio Output Impedance
10KΩ or
The RD-10 is a single function remote control and alarm, with status monitor for placement in the field. It has ten
open collector outputs that can be set for momentary, latched, or repetitive On/Off output from a manual DTMF
keypad, another RD-1, RD-10 or an RC-10.
The RD-10 has ten Inputs which can be debounced, timed, and monitored fr
Be certain to follow standard anti-static procedures when handling any of Midian’s products.
P1-1 to P1-10: Opto-Isolated Inputs: These are the high side status inputs of the opto isolators. See Isolator
Terminal statement on P1-12.
P1-11: V Com-2: This is a V common for inputs 5-10 of the optional opto isolators. In the schematic y
Each of 10 outputs on the RD-10 can be individually commanded to turn on or off from a remote location. The
outputs can be commanded manually from a variety of remote control devices, including:
•
a field radio with a DTMF keypad
•
a Midian RD-1 or RD-10
•
a Midian RC-10
The state of each output can be individually programm
Alarm And Report Queuing
Both Status Report/Alarms and Event Alarms are normally queued in case the channel is busy when the
conditions that cause them occur. The transmissions will be sent when the radio channel becomes available.
This feature can be turned off separately for both Status Reports/Alarms and Event Alarms. Status
Reports/Alarms that have been
Report Alarm Status
#XXXG*4#
XXX is the 0 to 3 digit base address assigned when the unit was programmed. G is the addressed I/O Group.
The unit will report the status of the addressed alarm with a low→high or high→low tone sequence. For more
information about alarm conditions please refer to the Help files in the Remote Programmer.
Program On Time
#XXX
The RD-10 provides a secure mode of operation to eliminate false operation from spurious transmissions and
helps thwart hacking attempts.
The lead-in tone is timed at 200ms and the following tones are timed using a base of 50ms on time and 50ms
inter-digit time.
The digits A to D are used as command digits. These digits don't appear on most two way
The RD-10 is programmed using Midian’s KL-3 programming cable and software. For further information, consult
either the KL-3 Instruction Manual or the Remote Programmer online help files.
To connect the RD-10 to the KL-3 cable, attach the ground lead of the KL-3 to P1-20 (Ground) of the RD-10, and
the programming lead of the KL-3 to P1-