10 Input / 10 Output Remote Monitor and Remote Control

Manual Revision: 2010-08-10 Covers Firmware Revisions: 4.0 & Higher Covers PCB Revisions: C 1

TABLE OF CONTENTS

Specifications 3 General Information 4 Hardware Installation 5 Operation 6 Product Programming 10 Technical Notes 12 Contact Information 12 2

2 mA each

Relay Current 17 mA each Audio Inputs Input Level 400 mVRMS Input Impedance 470KΩ Dynamic Range 25 dB Format DTMF SINAD Ratio 9 dB Band Width 2.5% Twist 10 dB Audio Outputs PTT Output Current 200 mA Audio Output Level 1V RMS Audio Output Impedance 10KΩ or

The RD-10 is a single function remote control and alarm, with status monitor for placement in the field. It has ten

open collector outputs that can be set for momentary, latched, or repetitive On/Off output from a manual DTMF keypad, another RD-1, RD-10 or an RC-10. The RD-10 has ten Inputs which can be debounced, timed, and monitored fr

Be certain to follow standard anti-static procedures when handling any of Midian’s products.

P1-1 to P1-10: Opto-Isolated Inputs: These are the high side status inputs of the opto isolators. See Isolator Terminal statement on P1-12. P1-11: V Com-2: This is a V common for inputs 5-10 of the optional opto isolators. In the schematic y

Each of 10 outputs on the RD-10 can be individually commanded to turn on or off from a remote location. The

outputs can be commanded manually from a variety of remote control devices, including: • a field radio with a DTMF keypad • a Midian RD-1 or RD-10 • a Midian RC-10 The state of each output can be individually programm

Alarm And Report Queuing

Both Status Report/Alarms and Event Alarms are normally queued in case the channel is busy when the conditions that cause them occur. The transmissions will be sent when the radio channel becomes available. This feature can be turned off separately for both Status Reports/Alarms and Event Alarms. Status Reports/Alarms that have been

Report Alarm Status

#XXXG*4# XXX is the 0 to 3 digit base address assigned when the unit was programmed. G is the addressed I/O Group. The unit will report the status of the addressed alarm with a low→high or high→low tone sequence. For more information about alarm conditions please refer to the Help files in the Remote Programmer. Program On Time #XXX

The RD-10 provides a secure mode of operation to eliminate false operation from spurious transmissions and

helps thwart hacking attempts. The lead-in tone is timed at 200ms and the following tones are timed using a base of 50ms on time and 50ms inter-digit time. The digits A to D are used as command digits. These digits don't appear on most two way

The RD-10 is programmed using Midian’s KL-3 programming cable and software. For further information, consult

either the KL-3 Instruction Manual or the Remote Programmer online help files. To connect the RD-10 to the KL-3 cable, attach the ground lead of the KL-3 to P1-20 (Ground) of the RD-10, and the programming lead of the KL-3 to P1-