EN0H-0001IT01 R1007 MT2000B1004 Telephonic module GSM INSTALLATION INSTRUCTION PRESENTATION MT2000B is a GSM instrument designed for remote control of device connected to it (boiler, chrono- thermostats, fan-coils, air conditioners, etc.). With a simple command sent via sms it is possible to control an external device, know its status (on or off), or have information concerning the ambient temperature. The device is protected by a password (pre-settable), which prevents its unauthorized use. INDEX (1) INSTALLATION (2) INTERFACES (3) LOCAL ACTIONS (4) FUNCTIONS (5) INITIAL SETTONGS (6) COMMANDS (7) NOTIFICATION SMS (8) NAMPLATE DATA (9) ACCESSORIES (10) TROUBLE SHOOTING (11) WIRING DIAGRAMS (12) WARRANTY (13) CE DECLARATION OF CONFRORMITY 1 INSTALLATION For correct operation of the device, it requires a SIM Card in Plug-in format (not included) enabled to receive and transmit sms messages, and not protected by a PIN code. N.B.: before inserting the SIM Card, remove (if present) the PIN code protection by using a cell phone. Install the device on an interior wall sheltered from the sunlight and all sources of heat such as lamps, television sets, and draughts. The product should be installed within the following temperature range: from -5°C to +45°C. Procedure: • make sure that the device is off; • locate the SIM Card holder and exert a slight pressure on the yellow release pin of the SIM port using a pencil; • insert the SIM Card in its holder making sure of its correct orientation; • close the SIM card port by pressing it fully home (with great care); • screw the antenna on relative connector (without applying excessive force); • place the product on a firm surface making sure that a good signal of the GSM operator is present; • connect the external instrument with due observance of all necessary regulations; • power up the device. When switching on for the first time the settings are those given in section (5). 2 INTERFACES LED MULTIFUNCTION BU TTO N ANTENNA CONNECTION NETW ORK LED The Push button allows: • modifying the output status (manual switching of the output); • activating display of the GSM network field strength detected by the device. The Multifunction Led allows: • displaying the output status; • displaying the level of the GSM network field strength detected by the device. Network Led: • prolonged flashing (i.e. the led remains lit up for a log time): indicates that the device is not connected to the GSM network and is in a coverage search phase, or else the SIM Card is incorrectly inserted, or the SIM card is protected by a pin code; • rapid flashing (i.e. the led is almost always unlit): indicates that the device is connected to the GSM network and is ready to receive commando; • unlit: indicates that the GSM section is off. S U P P L Y O U T P U T Output: The device is provided with a bistable relay output. • If the external device to be controlled is switched on when the command line is closed, proceed to connect such line to N.A. and COM terminals. • If the external device to be controlled is switched on when the command line is opened, proceed to connect such line to the N.C. and COM terminals. If such instructions are followed, the association between status of the device connected and the multifunction led is as follows: • Green Led : external device On (COM-NA). • Red Led : external device Off (COM-NC). Power Supply: The power supply for the device should be from 9 and 12V DC with current lying between 300mA and 500mA.

INSTALLATION INSTRUCTION - MT2000B1004

subject to updating without notice EN0H-0001IT01 R1007 3 LOCAL ACTIONS After start-up of the device is possible to: • switch the status of the relay output by pressing the push button for e period of time between 1.5sec and 5sec. • Display the GSM network field strength by pressing the push button and holding it down until the multifunction led goes out (about 15sec. after). After the multifunction led goes out, the following visual information in supplied: o Red, steady light: critical coverage, reposition the antenna. o Red\Green, flashing: poor coverage, reposition the antenna if possible. o Green, light: sufficient coverage. If the push button is pressed for less than 1.5sec or between 10 and 15sec., no action in involves. 4 FUNCTIONS TFUNCTION This function allows displaying information regarding ambient temperature in each Status Notification sms; it can only be Activated\Deactivated via sms. Restart This function allows switching off (and then restarting) the GSM section at preset intervals (from 1 to 7 days). It can only be Activated\Deactivated via sms. When the radio section is off, the device is not able to receive or send sms, nor can it perform local commands (for approx. 20 seconds). This function allows simulating the disconnection, and subsequent re-connection of the GSM network by the device in order to maintain a discrete value of priority in the operators’ queues. Such function is useful in places where there is risk of the GSM network signal missing even for several days. 5 INITIAL SETTONGS After the first installation, default settings are as follows: • Password: 0000 • Output: OFF (COM-NC, multifunction led red) • TFUNCTION: OFF • Restart: OFF • Threshold Temp. (TS): +20.0°C The default settings can be restored at any moment by proceeding as follows: • Switch off the device; • Press and hold down the push button; • Power up the device (the multifunction led remains unlit for approx. 5 seconds); • When the multifunction led lights up, release the push button; The settings have been restored. The settings are saved permanently in the internal memory of the device. In the event of a power failure, the memorized settings are not lost and they are restored when switching on. The settings can be modified via sms. 6 COMMANDS The sms command should be sent to the cell phone number corresponding to the SIM card inserted in the device installed. Format of a command sms: PASSWORD # COMMAND[PARAMETERS] Password example: 0000 (Default value) Activate Output (1 - One) Sms example: 0000#1 Multifunction led: Green Output: COM-NO closed COM-NC open After execution, the device sends a Status Notification sms to the sender’s cell number. Deactivate Output (0 - Zero) Example sms: 0000#0 Multifunction led: Red Output: COM-NO open COM-NC closed After execution, the device sends a Status Notification sms to the sender’s cell number. Request Status (?) Example sms: 0000#? Multifunction led: no modification Output: no modification The device sends a Status Notification sms to the sender’s cell number containing the output status and information regarding the functions activated (see 7). Change Password (P) The password should consist of four digits. Example: current password 0000, new password required 1234. Example of Change Password sms: 0000#P#1234 The device sends a Status Notification sms to the sender’s cell number containing the new password. Activate\Deactivate TFUNCTION (T) Example of Activation sms: 0000#T1 example of Deactivation sms: 0000#T0 For further information see 4. If activated, the following wording appears in a Status Notification sms: T=”Temperature Measured” Activate\Deactivate Restart (R) The restart period can be preset from 1 to 7 days. For further information see 4. Example of Activation sms: 0000#R3 set the Restart period to 3 days. Example of Deactivation sms: 0000#R0 When activated, the following wording appears in a Status Notification sms: Restart: “days elapsed”/”period” where: • days elapsed: indicates the number of days elapsed since the last restart • period: indicates the restart period, i.e. every how many days does the device restart the radio section.

INSTALLATION INSTRUCTION - MT2000B1004

subject to updating without notice EN0H-0001IT01 R1007 7 NOTIFICATION SMS After receiving a command sms, the device can send three different modification sms messages to the sender of the command: Error Notification Sms The device sends this sms if the command sent does not exist or cannot be activated, or if the command parameter is not valid. Content of this notification sms are as follows: ERROR! Password Change Notification Sms The device sends this sms after receiving the P command to notify successful change of the password. Contents of this notification sms are: New Password: P1P2P3P4 where P1P2P3P4 is the new password set. Status Notification Sms The device send this sms after executing any of the command (excluding P). A status Notification Sms contains the information regarding the current status of the output and the function activated. Examples: • Output On, no Function Activated: ON. • Output On, and TFUNCTION Activated: ON. T=+22.0°C • Output On, Restart Activated (period = 7 days) ON. Restart: 2/7 The device does not send any type of notification sms if the sms received is not recognized as valid (e.g. incorrect or invalid password). 8 NAMPLATE DATA Power supply: Volts: 9-12V DC Amps: 500mA Max Average Power Consumption: Standby: 40mA Sendig\Receving sms: 100mA Output Type: bistable relay SPDT Contact Load Capacity (MAX): 0.25A 250VAC 62.5VA 0.5A 125VAC 62.5VA 2A 30VDC 60W 9 ACCESSORIES • Rod antenna. • Power supply unit. 10 TROUBLE SHOOTING Q: The device doesn’t operate after plugging the power supply unit in the wall mount socket A: Make sure that the power supply cable have been connected as indicated in the manual and that all instructions given in it have been followed. Q: the network led continues to emit prolonged flashes. A: If the device has only just been switched on, wait for a few moments. Consult the interface chapter. Q: After installing the device, it is not possible to switch the output status manually or request visualization of the GSM network field strength. A: ) if the device has just been activated, wait for a minute and try again. 2) If the network led emits prolonged flashes, the SIM card is protected by a PIN code, or else it has been inserted incorrectly. Check. Q: After sending a command sms, the notification sms messages arrive late or else they are not delivered. A: 1) The MT2000B device operates by using a radio sign, no mobile telephone operator is able to guarantee connection at any instant. For this reason, the MT2000B device cannot be used in life support systems.2) Make sure that there is credit on the SIM card.3) Make sure that the device has been installed in a place where the GSM network signal is present. Q: Sometimes, during normal operation of the device, the network led goes out, then lights up again after about 20 seconds. A: if the Restart function is Activated, the network led goes out cyclically (depending on the period preset) thus signaling that the radio section is switched off. 11 WIRING DIAGRAMS Connection to chrono-thermostat enabled 12 WARRANTY The product is warranted for 12 months from the date of purchase, as proved by the purchase document. The company declines all liability for injury or damage which may occur to persons, property or animals, as a result of failure to observe all the instructions given in the user manuals. 13 CE DECLARATION OF CONFRORMITY With this document, the manufacture declares that the device conforms with the essential requirements and the other provisions set forth in the directive 1999/5/CE. Honeywell Honeywell S.r.l. http://www.honeywell.it ACS Environmental Controls Via P.Gobetti, 2b 20063 Cernusco Sul Naviglio – MI (I) Tel 02-92146.1 Fax 02-92146-402

Other GSM/GPRS Modules Manuals