ABB SM1000 Installation Instructions Manual
Read Online
Read the ABB SM1000 Installation Instructions Manual online using the built-in PDF viewer.
SM1000 Installation Instructions Manual: Key Pages of Document
SM1000, SM2000 and SM3000 Paperless recorders I/O module board installation 1 Introduction This publication describes the procedure for installing the following I/O module boards in SM1000, SM2000 and SM3000 recorders. GR2000/0703 3-relay module board service pack GR2000/0704 6-relay module board service pack GR2000/0705 Hybrid module board service pack GR2000/0706 Transmitter PSU module board service pack GR2000/0708 6-channel, analog input module board service pack GR2000/0714 High-specification, 6-channel analog input module board service pack In addition to the I/O module ...
3 I/O module board installation (SM1000 and SM2000) CAUTION The recorder is vulnerable to electrostatic damage. Wear an anti-static strap or dismantle the unit on an anti-static workbench. 1 Isolate the recorder from the power supply. 2 Referring to Figure 1, remove the recorder from its case. Note. Refitting is the reverse of removal. Withdraw the recorder from its case Remove tamper-evident seal (if fitted) Unscrew the jacking screw 1 2 3 Terminal cover (if fitted) Figure 1 Removing the recorder from its case 3 Referring to Figure 2 , remove the chassis t ...
3 4 Referring to Figure 3, remove the existing I/O module board (if fitted) and fit the new I/O module board. CAUTION For the recorder to function correctly, it is important to ensure that the I/O module boards are fitted in the correct positions. If replacing an existing I/O module board, note its position and withdraw it from the chassis (Analog I/O module board in position A shown) A B C D Relay, transmitter PSU or hybrid module board Relay, transmitter PSU, hybrid or ethernet module board Determine the correct position for the new I/O module board. Replaceme ...
…3 I/O module board installation (SM1000 and SM2000) 6 Referring to Figure 1 on page 2, unscrew the 3 captive screws securing the terminal cover and remove the cover (if fitted). 7 Referring to Figure 5, fit the 20-way connector. Note. Refer to the User Guide (IM/SM1000 or IM/SM2000) for connection details for all I/O module boards. A B C D Module positions Affix the label to the 20-way connector Insert the 20-way connector into the appropriate slot 3 2 Remove the 2 x PCB terminal block guides from the 20-way connector and discard 1 Note. To remove a 20-wa ...
5 8 Referring to Figure 1 on page 2, refit the terminal cover (if fitted). 9 Referring to Figure 6, refit the PCB locking bar and chassis top cover. CAUTION When positioning the chassis top cover, take care not to damage the EMC contacts. 10 Referring to Figure 1 on page 2, refit the recorder to the case. 11 Restore the power supply to the recorder. EMC Contacts Position top cover as shown Slide forward Lower rear Refit screws (one each side) Refit PCB locking bar ensuring that the slots in the bar locate correctly on the boards and chassis 1 2 3 4 5 5 Figure 6� ...
…4 I/O module board installation (SM3000) 3 Referring to Figure 8, remove the existing I/O module board (if fitted) and fit the new I/O module board. CAUTION For the recorder to function correctly, it is important to ensure that the I/O module boards are fitted in the correct positions. 1 Remove PCB locking bar securing screws (one each side)… 3 2 …and remove PCB locking bar When fitting a new or existing module board, ensure that the lugs locate correctly into the slots on the motherboard If replacing an existing I/O module board, note its position a ...
7 4 Referring to Figure 7 on page 5, loosen the 3 screws securing the terminal cover and remove the cover (if fitted). 5 Referring to Figure 9, remove the recorder case blanking plate (if fitted) and fit the 20-way connector. Note. Refer to the User Guide (IM/SM3000) for connection details for all I/O module boards. 6 Referring to Figure 7 on page 5, refit the terminal cover (if fitted) and refit the recorder to its case. 7 Restore the power supply to the recorder. 1 Remove self-adhesive blanking plate from appropriate slot ininstrument case Affix the appropria ...
— We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB. © ABB 2019 — ABB Limited Measurement & Analytics Howard Road St. Ne ...
Measuring Instruments PDF Instructions
WESCHLER INSTRUMENTS DIVISION OF HUGHES CORPORATION OWNERS MANUAL for BG Series REVISION 2.8 10/17 16900 Foltz Industrial Parkway, Cleveland, Ohio 44149 Phone: 440-238-2550 Fax: 440-238-0660 Email: [email protected] User operation guide for the weschler instruments BG Series Measuring Instruments. It explains interface navigation, power requirements, user preferences, setup guidelines.
DT-9989 Bluetooth User Help I. Driver Installation and identification of COM PORT 1. Insert the PC-4.0B (the blue USB which delivered together with the Multimeter) into the computer and open the Device Manager, as shown in Figure 1 below. If the Bluetooth of y Operation instructions for the CEM DT-9989 Multimeter. This guide explains the features and network configuration, software configuration, cleaning instructions, adjustment procedures.
This is the product user guide for the 117400-60 and 117400-120 Colt compact broadband seismometer. Reftek Systems Inc. 75 MacDonald Avenue, Unit 1 Dartmouth, Nova Scotia Canada Support: 1-902-444-0539 Email: [email protected] www.reftek.com REF TEK Colt™ B Complete device guide for the Reftek REF TEK Colt Measuring Instruments. This guide offers instructions on product specifications, diagnostic information, menu navigation, operating guidelines.
Instruction Manual Product reference manual for the Minelab gpz 7000 Metal Detector. This documentation details calibration steps, device reset instructions, safety protocols.