activTek AP3000 Manual 

Specifications

Brand: activTek
Category: Air Cleaner
Model: AP3000 (Manual ), prEuWU.JlsYF2
File Type: PDF
File Size: —
Pages: 16 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (16 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 13/05/2026).

Read Online

Read the activTek AP3000 Manual  online using the built-in PDF viewer.

AP3000 Manual : Key Pages of Document

READ MANUAL CAREFULLY FOR PROPER USE AND OPERATION

Portable Whole Home Office System ...

Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Specifications . . . . ...

YOUR NEW AP3000

SPECIFICATIONS Electrical: 100 ~ 240 VAC 50/60 Hz External Power Supply Power Consumption: 50 Watts Negative Ion Generation Purification Plate Output (High Mode): > 0.05 ppm Coverage: 250 to 3,000 sq. ft. (23 to 279 m²)** Dimensions: 12” high x 9” wide x 12” deep Weight: 10.2 lbs. Warranty: Three (3) Year Limited Warranty, see page 15 for specific instructions **Depends on variables such as severity and frequency of pollution, humidity, and temperature. • Eliminates smoke, odors, and tobacco smoke • Includes ActivePure® (RCI) Technology • High-intensity UV lamp • Removes odors from a home, office, car, boat, RV, et ...

1. Remove protective packaging

2. Remove unit from shipping carton 3. Remove all protective materials 4. Check for shipping damage and loose or broken parts 5. Read Owner’s Manual thoroughly prior to installation 6. Install batteries in remote 7. Determine placement location for the unit (See “Placement of Unit” on page 5) 8. Insert the power supply plug into the power receptacle on the rear of the unit. Plug the appropriate cord into the power supply and into a working electrical outlet 9. Using either the remote control or the Power button, turn the unit ON FEATURES Back of Unit/Rear Access Power Cord Receptacle Po ...

PLACEMENT OF UNIT

The LCD Screen is used to display all current settings as well as any maintenance reminders. LCD SCREEN BACKLIGHT As adjustments are being made, the LCD screen backlight will brighten and the settings on the screen will change. After 3 seconds without change, the backlight will return to normal. If a maintenance reminder or a service reminder appears, the backlight will brighten and constantly flash until the Reminder Reset button is pressed or the service problem is corrected. LCD DISPLAY Place unit as high as possible to ensure complete purification (On top of a bookshelf, high cabinet, etc.). Suggested locations listed in order o ...

1. Adjust the fan speed to your preference, keeping in mind that higher fan speeds will give better results.

2. Using the Normal/High button, set the unit to NORMAL, for typical use, or HIGH, for increased smoke and odor control. 3. For HIGH MODE, using the PURIFIER UP and PURIFIER DOWN buttons on the remote control, adjust the purifiation level to its lowest setting (250 sq. ft. (23m2) for the first 24 hours of operation, them gradually adjust up (if needed) to the square footage (or square meters) of the indoor area. HIGH MODE: The unit’s display shows the fan speed (low to high), the purifier setting (1 bar to 12 b ...

SETTINGS AND ADJUSTMENTS

AP3000 can be turned on or off using either the included remote or the control panel on the front of the unit. NOTE: “Unoccupied areas” includes pets. Some pets, like humans, may experience adverse reactions from exposure to increased levels of ozone and should not be present during Away Mode operation. POWER (standby) Turns the unit ON and OFF. REMINDER RESET (control panel only) Clears the maintenance reminders after performing routine maintenance. Fan Up/Fan Down Adjusts the five speed fan. Away Mode When the AP3000 is switched to the “Away Mode,” the Corona Discharge Ozone Plate is operated at maximu ...

The purifier plate is not functioning properly. Replace the old purifier plate with a new purifier plate (available from your

local activTek Distributor). MAINTENANCE REMINDERS NOTE: The ActivePure® (RCI) Cell should be replaced every year if used continuously, even if the unit does not display this message. Replace every two (2) years if used less than 12 hours a day. NOTE: Be sure to press the Reminder Reset button to clear the reminder following regular maintenance (see below). REPLACE RCI CELL The ActivePure® (RCI) Cell is no longer working correctly. Replace the ActivePure® (RCI) Cell (replacement Cells are available from y ...

Periodic maintenance is required to ensure that your AP3000 by activTek operates properly. The unit will display a PERFORM

CLEANING reminder when it’s time to perform regular maintenance. If you are operating your unit in a severely polluted environment, cleaning of the unit, purifier plate, ActivePure® (RCI) Cell, and Filter Assembly should be done more frequently. Shown here are basic procedures that should be carried out to keep your unit running at top performance. For optimal performance, and to prevent damage not covered by your warranty, install the optional AP3000 purifier prefilter. Failure to perform routine maintenan ...

ActivTek’s Optional Harsh Environment Prefilter is designed specifically for areas with tobacco smoke, multiple

pets, or anywhere excessive levels of contamination are in the air. • Protects your air purifier from indoor contaminants, which may shorten the life of your product. • Reduces monthly maintenance and cleaning time up to 90% • Helps reduce odors • Replaces easily, once a month, when cleaning unit • Great in kitchen environments • Helps reduce VOC’s and other contaminants • Optional Harsh Environment Prefilter (#9950123) 2. Remove the Filter Assembly by pulling back the top, then lifting up and out. 1. Remove the ...

1. Unplug unit.

2. Remove the back cover screw. 3. Remove back cover. Press the sides to unlatch, then tilt the bottom out to remove. 4. Remove two (2) thumbscrews securing the top of the Filter Assembly. 5. Remove the Filter Assembly by pulling back the top, then lifting up and out. REMOVING THE PURIFIER PLATE & ACTIVEPURE® (RCI) CELL REMOVING THE FILTER ASSEMBLY WARNING: Do not operate the AP3000 without the Filter Assembly and back cover properly installed. Use genuine activTek replacement parts only. Parts from anyone other than activTek may damage your unit and void your warranty. NOTE: 4. Remove two (2) thumbscrews. 5. Slide the ActiveP ...

INSTALLING THE PURIFIER PLATE & ACTIVEPURE® (RCI) CELL

INSTALLING THE FILTER ASSEMBLY When installing the purification plate, be sure that the metal tabs are making contact with the screen on each side of the plate. 2. Replace the two (2) thumbscrews and tighten. 1. Slide the ActivePure® (RCI) Cell up and into the unit. Be sure the back lip of the ActivePure® (RCI) Cell engages the two slotted protrusions at the rear of the plate cage, and that the angle brackets and studs are correctly aligned. 4. Gently insert the purifier plate between the guides (inside the cage) until it stops. 3. Insert the ActivePure® (RCI) Cell connector into the pl ...

Indicators of Operation:

When the unit is on, the LCD display will show either the fan setting and NORMAL, or the fan setting, purifier setting, and square footage. If the unit is in Away Mode, it will display AWAY MODE plus the hours and minutes remaining. See page 6 for more information. Troubleshooting – What to look for first: 1. I have plugged in the unit, pressed the ON button on the remote (or the unit), and nothing happens… what’s wrong? • Make sure the power cord is inserted completely into the receptacle on the back of the unit •  Make sure the electrical outlet is capable of providing power to the unit •  ...

REPLACEMENT PARTS LIST

Item # US70728:  Ozone-Producing ActivePure® (RCI) Cell output (Normal Mode): > 0.05 ppm ozone (ambient room concentration) Item # US71090:  Ozone-Free ActivePure® (RCI) Cell output (Normal Mode): 0 ppm ozone (produces no ozone) Item # US70171: Purification Plate Item # US70730: Filter Assembly Item # 9950117: Power Supply with U.S. and Euro Cords Item # 9950123: Optional Harsh Environment Prefilter NOTE: The UV output of the RCI Cell bulb will decrease over time and should be changed every year if used continuously, or every two (2) years if used less than 12 hours a day, even if the bulb is still producing l ...

LIMITED 3 YEAR WARRANTY

Customer should not repackage and ship the AP3000 unit due to possibility of irreparable damage. For warranty service, please contact your activTek Distributor for the address of the nearest service center. WHAT IS COVERED BY THIS WARRANTY We warrant the AP3000 (excluding filters) to the Customer, subject to the conditions below, against defects in workmanship or material, provided that the products are returned to a service location within the following time periods: • AP3000 within three (3) years of date of purchase. • ActivePure® Cell and Lamp within one (1) year from the date of purchase. INSTA ...

FCC DECLARATION OF CONFORMITY

Name: AP3000 Model: A1005G Manufacturer: DBG Group Investments, LLC This device complies with Part 18 of the FCC Rules. RESPONSIBLE PARTY DBG Group Investments, LLC DBA activTek Environmental 300 East Valley Drive Bristol VA, 24201 Ph: 866-736-0503 Signature:___________________________ Printed Name: Andrew Eide Title: Vice President of Product Development and Manufacturing Date: 09/27/2018 This equipment has been tested and found to comply with the limits for Industrial, Scientific, and Medical Equipment (ISM), pursuant to Part 18 of the FCC Rules. These limits are designed to provide reasonable protection against h ...

Air Cleaner PDF Instructions

Better Air BA-1000Pro Quick start installation manual
Better Air BA-1000Pro
17.06.2026 2 pages

Quick Start Installation Guide BA-1000Pro Contact Us 844.44.PROBIO [email protected] betterairus.com WARNING The BA-1000Pro should only be used with the power pack provided by the manufacturer. KEEP OUT OF REACH OF CHILDREN. AVOID SWALLOWING AND EYE CONT

Auga VarioClean Pro Operation instructions manual
Auga VarioClean Pro
05.04.2026 28 pages

www.auga.nl 1 UV-c apparaten – Stérilisateur UV-c UV-C Strahler - UV-c devices VarioClean Pro G e b r u i k s a a n w i j z i n g – I n s t r u c t i o n s d ’ u t i l i s a t i o n B e d i e n u n g s a n l e i t u n g – O p e r a t i o n i n s

Blueair 400 Operation & user’s manual
Blueair 400
21.04.2026 9 pages

Blueair Classic User Manual - 400 series

Santa Fe KF-P32 Installation & operation instructions
Santa Fe KF-P32
05.06.2026 11 pages

1 Santa-Fe-Products.com Santa Fe Air Purifier Installation & Operation Instructions Serial Number Install Date Sold By Installation & Operation Instructions The Santa Fe Air Purifier utilizes HEPA-grade filtration and UV sterilization capability to clean your