ACP RMS510TS2 Technical Information

Text of ACP RMS510TS2 Technical Information

ACP RMS510TS2 Commercial Microwave—Technical Information

230V, 50 Hz Models RMS510TS2 P2006703M RMS510DS2 P2006704M RMS510TSUA P2006707M RMS510DSUA P2006708M RMS510TSCA P2006709M RMS510TSIA P2006710M RMS510TSAA P2006711M Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer to Owner’s Manual for installation and operating instructions July 2019 1 ©2019 ACP, Inc

©2019 ACP, Inc.

2 16500066 Component Testing Procedures Illustration Component Test Results Thermal Cutout Disconnect all wires from TCO. Measure resistance across terminals. Cavity TCO………… ...................................... Magnetron TCO .............................................. Open at 203° F (95° C) Closes at 185° F (85° C) Open at 293° F (145° C) Closes at 275° F (135° C) Diode/Rectifier Discharge Capacitor Remove d
©2019 ACP, Inc. 3 16500066 Component Testing Procedures Illustration Component Test Results Transformer HV Fuse (Terminal 4) Discharge Capacitors Remove all wires from terminals. Measure resistance from: Terminal 1 to Terminal 2.................................. Wire 5 to Wire 6 ............................................... Terminal 4 to Ground screw on transformer... Terminal 4 to any other terminal ...................... Resistance 2.0 Ω.
©2019 ACP, Inc. 4 16500066 Power Output Wattage Testing Procedure All Amana and Menumaster microwave oven power outputs are rated using the IEC705 standards. Using the IEC705 test method requires precision measurements and equipment that is not practical to be performed in the field. Using the test shown below will indicate if the oven performance is satisfactory. Test equipment required:  1000 ml test container and thermometer.  Digital w
©2019 ACP, Inc. 5 16500066 Wiring and Schematic Diagrams To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor before servicing, unless testing requires power.
©2019 ACP, Inc. 6 16500066 Electronic Control Operation So…how do I use it? (A) ( B) (C) (D) (E) (F) (G) Note: Control panel coloring may vary by model Control Panel Features (A) LED DISPLAY (B) TIME ENTRY KEY (C) X2 KEY (D) POWER LEVEL KEYS (E) NUMBER KEYS / PRESET PROGRAM KEYS (F) STOP/RESET KEY (G) START KEY Interrupting Operation (Pause Mode) While the oven is operating, press STOP/RESET key to interrupt operation
©2019 ACP, Inc. 7 16500066 Electronic Control Operation Programming Mode This mode allows the user to assign cook times, power levels, and stage cooking to the Number Keys. 1. Open oven door and press and hold Number Key “1” for 5 seconds. The oven beeps and LED displays “ProG”. Note: If STOP/RESET key is pressed before programming is complete,changes are discarded and microwave exits programming mode. 2. Press a Number Key to change
©2019 ACP, Inc. 8 16500066 Electronic Control Operation On-the-Fly Cooking On-the-Fly Cooking allows the user to start another cook cycle while the oven is operating or paused. Note: User Option OP:51 must be enabled for use of On-the-Fly cooking. 1. While the oven is cooking or while in Pause Mode, press a Number Key to automatically start the Preset Program associated with that key. 2. Oven begins cooking and the LED displays cooking time. 3.

ACP Microwave Oven Owners Instructions: