Bailey Infi 90 NIAC03 Instruction

Text of the manual

Process Control and

Automation Solutions from Elsag Bailey Group E96-425 Analog Input Calibration Module (NIAC03)

WARNING notices as used in this instruction apply to hazards or unsafe practices that could result in

personal injury or death. CAUTION notices apply to hazards or unsafe practices that could result in property damage. NOTES highlight procedures and contain information that assists the operator in understanding the information contained in this instruction.

The NIAC03 Analog Input Calibration Module provides a

means to calibrate 100 ohm resistance temperature detector (RTD) inputs for the IMASM03 Analog Slave Module. This manual explains how to install and use the NIAC03 mod- ule on the INFI 90® Strategic Process Management System. It has sections that describe the setup and cabling. The app

List of Effective Pages

Total number of pages in this manual is 20, consisting of the following: Page No. Change Date Preface Original List of Effective Pages Original iii through v Original 1-1 through 1-5 Original 2-1 through 2-5 Original 3-1 Original 4-1 Original 5-1 Original A-1 Original Index-1 Original NOTE: On an updated page, the change

Sommaire de Sécurité

GENERAL WARNINGS Equipment Environment All components, whether in transportation, operation or storage, must be in a noncorrosive environment. Electrical Shock Hazard During Maintenance Disconnect power or take precautions to insure that contact with energized parts is avoided when servicing. SPECIFIC CAUT

Table of Contents

Page I-E96-425A iii SECTION 1 - INTRODUCTION....................................................................................................1-1 OVERVIEW ..................................................................................................................1-1 INTENDED USER......................................................

List of Tables

® 1-1. Reference Documents ............................................................................................ 1-4 1-2. Glossary of Terms and Abbreviations ..................................................................... 1-4 1-3. Nomenclature..........................................................

1 - 1

SECTION 1 - INTRODUCTION OVERVIEW The NIAC03 Analog Input Calibration Module is required to calibrate the IMASM03 Analog Slave Module (100 ohm resis- tance temperature detector (RTD)). Calibration resistances are read from the NIAC03 module through the IMASM03 slave module. Calibration values are read across the slave expander bus a

1 - 2

I-E96-425A ® of devices that can be used with the calibration module in an INFI 90 system. • A standard factory-wired cable connects the calibration module to the slave module. • Each calibration module fits in a standard termination mounting unit. • Resistance temperature detector input calibration for the 100 ohm RTD inp