Autonics TZN Series Manual 

Specifications

Brand: Autonics
Category: Controller
Model: TZN Series (Manual ), pr4PGyepEs3k.
File Type: PDF
File Size: —
Pages: 16 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (16 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 20/07/2026).

Read Online

Read the Autonics TZN Series Manual  online using the built-in PDF viewer.

TZN Series Manual : Key Pages of Document

Dual PID auto tuning control

※1: Only for TZ4SP, TZ4ST, TZ4L, TZN4M Series. Features Ordering information ● Dual PID auto tuning function: High-speed response of PID control to reach to the desired value fast, low-speed of response of PID control to minimize the overshoot even though response is a little bit slow. ● High display accuracy: ±0.3%(by F.S. value of each input) ● 2-Steps auto tuning control function ● Multi-input function (13 kinds of multi-input selection function): Temperature sensor, voltage and current selection function. ● Various sub output function: Includes in LBA, SBA, 7kinds of alarm o ...

Dual PID Auto Tuning Control

※1. AC/DC power type is only for TZ4SP, TZ4ST, TZN4M, TZ4L Series. ※Environment resistance is rated at no freezing or condensation. Specifications Series TZ4SP TZN4S TZ4ST T ...

※RTD: DPt100Ω(3-wire type), JPt100Ω(3-wire type) ※T.C(Thermocouple): K, J, R, E, T, S, W, N

※In case of Analog input, please use T.C(Thermocouple) terminal and be careful about polarity. TZN4S TZN4M TZ4SP TZ4ST TZ4M Connections EV-1 OUT 250VAC 1A 1a SV2 IN Max.5VDC 250㎂ MAIN OUT 250VAC 3A 1c Resistive load SOURCE 100-240VAC 50/60Hz 6VA 24VAC 50/60Hz 8VA 24-48VDC 7W H C L B' RTD T.C SENSOR B A 5 2 10 9 8 1 11 4 3 7 6 MAIN OUT SSR Current 12VDC ±3V 30mA Max. DC4-20mA Load 600Ω Max. 9 9 10 10 mA V MAIN OUT SSR Current 12VDC ±3V 30mA Max. DC4-20mA Load 600Ω Max. 12 13 mA V 12 13 SV2 IN Max.5VDC 250㎂ MAIN OUT 2 ...

Dual PID Auto Tuning Control

Dimensions ● Panel cut-out TZN4S TZN4M TZ4L / TZN4L TZ4H / TZN4H TZ4W/TZN4W (unit: mm) 48 10 90 61 44.8 Min. 55 Min. 62 45 +0.6 0 45 +0.6 0 84 72 10 73 67 Min. 91 M ...

※Since TZ4SP uses same identification plate with TZ4ST, the lamp does not work even though it has a EV2 output signal lamp.

48 61 15 12 80 44.8 Min. 55 Min. 62 45 +0.6 0 46 +0.6 0 Min. 74 Min. 90 68 +0.7 0 68 +0.7 0 12 95 44.8 48 61 72 86 100 13 68 ● Panel cut-out ● Panel cut-out TZ4H TZN4H 48 96 108 48 96 108 90 13 90 Min. 50 Min. 112 45 +0.6 0 92 +0.8 0 ● Panel cut-out TZ4W TZN4W 108 96 48 108 96 48 100 13 44.8 Min. 112 Min. 50 92 +0.8 0 45 +0.6 0 ● Panel cut-out (unit: mm) ...

Dual PID Auto Tuning Control

1: Display Processing value(PV) (Red) 5: Mode key 9: Indicate EVENT 1 output 2: Display Setting value(SV) (Green) 6: Autotuning operation key 10: Indicate EVENT 2 output 3: Indic ...

Set alarm temperature in SV2.

Set range: Within the rated using range of each sensor. Set alarm temperature in EV-1. Set range: Within the rated using range of each sensor. Set alarm temperature in EV-2. Set range: Within the rated using range of each sensor. If press MD key for 3sec., it will go to parameter 1 group. Set monitoring time of loop break alarm. Set range: 0 to 999 sec. Set interval between ON and OFF for alarm output. Set range: 1 to 100℃ (0.1 to 100.0℃) ※It is only displayed for temperature alarm output. Set proportional band. / Set range: 0.0 to 100.0%. ※If setting value P as 0.0, it will be ON/OFF control. S ...

Dual PID Auto Tuning Control

Parameter 2 group Parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default IN-T KCaH AL-T AL-A PIDT PIdS H-SC 1300 EU-1 AL-1 AtT T ...

A) In case of sensor input : K(CA), J(IC), R(PR), E(CR), T(CC), S(PR), N(NN), W(TT), DPt 100Ω, JPt 100Ω

B) In case of voltage input : 1-5VDC, 0-10VDC C) In case of current input : DC4-20mA SW1 SW1 SW1 SW2 SW2 SW2 SW1:1 SW1:2 SW1:2 SW2: V SW2: V SW2: mA 1 1 2 2 2 2 V V V mA mA mA Input type and range Input type switch ※Factory default of input type switch: Temperature sensor input. ※Please select B) or C) according to input specification when it is voltage or current. Input type Display Input range(℃) Input range(℉) Thermocouple K(CA) H KCaH -100 to 1300℃ -148 to 2372℉ K(CA) L KCaL -100.0 to 999.9℃ This mode cannot ...

Dual PID Auto Tuning Control

This unit has output for control and sub(alarm) output. Sub output is optional. (This alarm output is relay contact(1a) and operates regardless of output for control.) Alarm outp ...

(tun 1 mode)

Auto tuning time Time(t) SV ℃ (tun 2 mode) Auto tuning time 70% of SV Time(t) SV ℃ Functions Auto tuning [ AtT] Sensor Break Alarm [ SBA] Sub output [ EU-1, EU-2] Error Loop Break Alarm [ LBA] PID auto tuning function automatically measures the thermal characteristics and response of the control system and then executes its value under high response & stability after calculating the time constant of PID required to control optimum temperature. ● ●Execute the auto tuning function at initial time after connecting the controller & the sensor. ● ●Execution of auto tuning is started when pressing AT key for ...

Dual PID Auto Tuning Control

Setting value (SV) Decrease reset Increase reset Normal deviation Normal deviation Process value(PV) (Fig. 1) SV S PV t PIdF ※ t : Reaching time S : Overshoot SV: ...

Control temperature when

ramp function is not used Control temperature when ramp function is used RAPU setting time RAPU setting time tu tu Initial SV Changing SV Cool / Heat function [ O-FT] SV2 function [ SU-2] If using SV2 function, it changes the temperature of control system to the second setting value by external relay contact signal. It can change the setting value as sequentially by relay contact without key operation. ● ●It can set SV2 at required time and particular area as like the above chart. ● ●SV2 is in parameter 1 group. ● ●Application : The control system, which h ...

Dual PID Auto Tuning Control

Equipment to be controlled Converter Analog output 1-5VDC 0-10VDC DC4-20mA TZ Series SSR Load power Power Voltage output terminal + - I N P U T L O A D T TZ Series DC4-20mA LOAD ...

Calculation range of Block Check Character

Start Code Header Code END Code BCC Code Address Code Text STX 10 1 10 0 R/W X/D ETX FSC Supply system power ※A → Over min. 4sec, B → Within max. 300ms, C → Over min. 20ms A B C TZ/TZN S T X A D R C M D T X T E T X B C C S T X A D R C M D T X T E T X B C C A C K S T X A D R C M D T X T E T X B C C Master Interface Standard EIA RS485 Number of connections Max. 31units. It is available to set address 01 to 99. Communication method 2 wire half duplex Synchronous method Asynchronous type Communication distance Within 1.2km Communication speed 2400, 4800, 9600(avail ...

Dual PID Auto Tuning Control

● Write of setting value In case setting value is -100 A C K S T X 0 1 W D S 0 Symbol 10 3 10 2 10 1 10 0 E T X F S C A C K S T X 0 1 W D S 0 - 0 1 0 0 E T X B C C 06 02 30 ...

Controller PDF Instructions

ZWK10
fakro ZWK10
24.06.2026 16 pages

www.fakro.com ZWK1 0 Z-Wave Controller User Manual 14.06.30 NC852-GB ENGLISH Technical setup manual for the fakro ZWK10 Controller. This manual details hardware components, support details, system checks.

RESISTRON RES-408
Ropex RESISTRON RES-408
22.07.2026 64 pages

ROPEX Industrie-Elektronik GmbH Tel.: +49 (0)7142-7776-0 E-Mail: [email protected] Adolf-Heim-Str. 4 Fax: +49 (0)7142-7776-211 Internet: https://ropex.de 74321 Bietigheim-Bissingen (Germany) Data subject to change 3.3.20 Version 1 RESISTRON RES-408 Important featu Complete installation manual for the Ropex RESISTRON RES-408 Temperature Controller. The document explains detailing setup, assembly reference, product safety, system checks.

xComfort Bridge
Eaton xComfort Bridge
28.08.2026 6 pages

Content - Innhold - Inhoud - Inhalt - Obsah Quick Installation Card xComfort Bridge CBCA-00/01 - 196811 Hurtig installasjon kort - Snelle installatiekaart - Schnellinstallationskarte - Karta pro rychlou instalaci © 2019 by Eaton Industries (Austria) GmbH Eug Product manual for the Eaton xComfort Bridge Controller. This manual covers software updates, power management, safety guidelines.

NOMAD POWER 12.24V
GYS NOMAD POWER 12.24V
16.04.2026 32 pages

V2_19/07/2016 FR EN DE ES RU 2 / 3-6 / 31-32 2 / 7-10 / 31-32 2 / 11-14 / 31-32 2 / 15-18 / 31-32 2 / 19-22 / 31-32 NOMAD POWER 12.24V www.gys.fr IT 2 / 23-26 / 31-32 NL 2 / 27-30 / 31-32 Product operation manual for the GYS NOMAD POWER 12.24V Controller. This documentation highlights features and dimensions and layout, functional overview, power requirements, replacement parts.