Burkert ME44 Quick Start Manual

File Specifications

Brand: Burkert
Category: Control Unit
Model: ME44 (Quick Start Manual), prBiqvG8zCTR2
File Type: PDF
File Size: —
Pages: 15 pages

Download PDF

Download Burkert ME44 Manual (15 pages)

Read Online:

Read the Burkert ME44 Quick Start Manual online using the built-in PDF viewer.

Key Pages of Document

Type ME44 / BPX3

I/O-Module / Backplane 8DI module, 8DO module, 4AI module, 4AO module 8DI-Modul, 8DO-Modul, 4AI-Modul, 4AO-Modul Module 8DI, module 8DO, module 4AI, module 4AO ...

The Quickstart contains extremely important information on the device.

Keep these instructions ready to hand at the operation site. Important safety information! ▶ ▶Carefully read these instructions. Observe in particular the safety instructions, intended use and operating conditions. ▶ ▶Persons, who work on the device, must read a ...

BASIC SAFETY INSTRUCTIONS

These safety instructions do not make allowance for any contingencies and events which may arise during assembly, operation and maintenance. The operator is responsible for observing the location-specific safety regulations, also with reference to the personnel. General hazardous situations. To prevent injury, ensure the followi ...

Electrostatically sensitive components and modules.

The device contains electronic components that are susceptible to electrostatic discharging (ESD). Components that come into contact with electrostatically charged people or objects are at risk. In the worst case scenario, these components are destroyed immediately or fail after start-up. •• Mee ...

4.4 Mechanical data

Housing material: Polycarbonate 4.5 Device labeling Order number CE marking Supply voltage Type Serial number Ambient temperature Manufacturer code (coded) QR-Code (further information on the device) Degree of protection UL marking* Module variant Nominal power * only UL version Fig. 1: Description of device labeling (Module) Order nu ...

4.6 Electrical data

Supply voltage: 24 V +20 %/–15 % via the backplane BPX3 Power consumption: 4AI: 3.5 W 8DI: 10 W 4AO: 3.5 W 8DO: 3 W Current consumption: 4AI: 4 x 50 mA 8DI: 8 x 30 mA 4AO: 4 x 50 mA 8DO: 8 x 750 mA Degree of protection: IP20 according to EN 60529 / IEC 60529 Standards: EMC EN 61000 PLC DIN EN 61131-2 UL devices: Limited Energy ...

→Align expansion socket of the fieldbus gateway with the expansion

connector of the backplane. → →Connect fieldbus gateway to the backplane. → →Using the M4 hexagonal socket head screw, screw the fieldbus gateway to the backplane. Observe tightening torque 0.75 Nm. The expansion socket for connecting the fieldbus gateway to the backplane is ...

Use supply voltage unit with adequate power.

5.3 Electrical installation The circuit diagram is pressed onto the outside of the I/O module. NOTE! Precondition to ensure that the device functions perfectly and to prevent interference: ▶ ▶Use only shielded cables with a braided or foil shield. Electrical configuration 8DI module: Plug configuration digi ...

Electrical configuration 4AI module:

Plug configuration AUX Power External circuit GND Ground GND Ground 24 V Aux Power External circuit 24 V +20 %/–15 % 24 V Aux Power External circuit 24 V +20 %/–15 % Plug configuration analogue inputs External circuit GND Ground AI1...AI4 Analogue input + 24 V External circuit 24 V +20 %/–15 % Tab. 3: ...

5.3.2 Connection of the cable shielding

NOTE! Precondition to ensure that the device functions perfectly. The cable shielding must be placed on both ends of the line to the functional earth: 1. On the I/O module • directly on the control cabinet input or • on a separate busbar directly on the module. 2. On the external sensor or actuator. 5.3.3 Conne ...

⚠️ Download Safety

The Control Unit Quick start manual (15 pages) is completely safe to download (last scan date: 07/08/2026).

Related PDF Instructions for Burkert ME44: