CMR Electrical LD32 CMR Electrical Ltd

Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel: 01825 733600 LD32 Water Leak Detection Manual

1) System Overview

2) Display and Control 3) Water Detected Alarm 4) Sensor Fault Alarm 5) Relay outputs 6)“Mute” push button 7) “Light” push button 8) “Info” push button 9) Beacon and beacon sounder 10) Fitting SCA repeat alarm or SMS / Email messaging system 11) Outstation 12) Positioning the Outstations 13) Fitting and wiring Alarm unit 14) Outstation wiring 15) RS485 data cable End of Line Resistor 16) Positioning the water detec
1) System Overview The unit has been designed to interrogate individual outstations and report back to the main controller if water or a disconnected sensor is found. On powering up, the unit will display “SETTING UP PLEASE WAIT” until all remote outstations have been interrogated for their current status. Providing there are no alarms or faults on the system, the displays backlight will change to green and all zones will be shown as “NORMAL”. Wi

2) Display and Control

Screen 1 Normal, no alarm or faults Screen 2 Unacknowledged (new) water leak detected Screen 3 Acknowledged water detected alarm Screen 4 Unacknowledged (new) Cable fault Screen 5 Acknowledged Cable fault Screen 6 System information 3) Water Detected Alarm When the detection cable comes into contact with water anywhere along its length, the audible warning device will start, the New alarm and common alarm relay will operate and dis

CMR Electrical LD32 5a) Outstation common alarm relay

Each outstation has its own common alarm relay for just the zones fitted to the outstation. Located on the top left of the outstation board (see above) use the two terminals provided. Note; this contact is only Normally open, Close in alarm. 6)“Mute” push button The mute button is provided to silence the audible warning device. This button will also silence the remote sounder if fitted. 7) “Light” push button In

10) Fitting SCA repeat alarm or SMS / Email messaging system

SCA Terminal No. SMS Terminal No. Cable wire colours fitted to the messaging system +V DC RED Sig Z1 BLUE 0V COM BLACK 11) Outstation Standard outstation Outstation with shutdown valve control Zone water & fault lights One set for each zone Terminal connection to detection cable or sensor one for each zone Test push button used to put the zone into alarm one for each zone RS485 data and power c

12) Positioning the Outstations

All outstations are wall mounted using the fixing points located in each corner behind the removable front cover. Outstations should be mounted in a position to allow accessibility to the internal components and cables. 13) Fitting and wiring Alarm unit Main control unit THIS EQUIPMENT SHOULD ONLY BE CONNECTED AND WORKED ON BY A QUALIFIED ELECTRICIAN. To mount the unit to a wall, first remove the front cover to expose the

CMR Electrical LD32 Output Volt Free contacts for use by a Building Management System.

Function Required Function New alarm Operates on each new water leak alarm or sensor fault, reset by muting Common Alarm Any zone in water alarm, clears with no water alarms on the system Common Fault Operates on disconnected sensor or power fault (See Item 5 above) Power Fault See Common Fault 14) Outstation wiring The maximum cable length is dependent upon the number of fitted outstatio

Valve control Outstation

Water detection and signal cable 16) Positioning the water detection cable The detection cable is susceptible to damage and should not be fitted to areas where the cable is likely to be damaged or walked on unless a perforated steel cover is used. If fitting the cable around Air Conditioning Units with humidifiers, ensure that cable is positioned at least one metre from the ACU to stop intermittent alarms bein

17) Fitting Cable Clips

If Cable Clips are required, to protect the small sensor wires and to stop false water detected alarms from occurring insulating tape should be first applied around the detection cable before the clip tongue is closed. Clips should be fitted approximately every 1 to 1.5 metres apart. When using clips make sure that the cable touches the floor between the clips, DO NOT tighten the cable so that the cable does not touch the floor.

CMR Electrical LD32 motor open, automatic close

Voltage 230VAC Buren 5 watt moving, <1 watt maintaining Operation Powered Open, capacitor reserve used to close Controlled fluid temperature -15 to 100°C Maximum pressure ½” ¾” 1” 1 ½” 2” 0-10 bar 0-10 bar 0-10 bar 0-10 bar 0-10 bar WARNING, In order to shut properly, this type of valve need powering for at least 3 minutes. Connection of Water Shutdown Solenoid Valve PLEASE NOTE; We don’t re