dallmeier MicroStreamer-PoE Installation And Configuration Manual
Read Online
Read the dallmeier MicroStreamer-PoE Installation And Configuration Manual online using the built-in PDF viewer.
Text of the manual
Rev. 2.0.0 / 100301
Installation and Configuration
Audio and video streamer
MicroStreamer-PoE
Information about copyright, trademarks, design patents
© 2010 Dallmeier electronic
All rights reserved. This document may not be copied, photocopied, reproduced, translated,
transferred to an electronic medium or converted to a machine-readable form either whole or in
part without first receiving written permission from Dallmeier electronic GmbH & Co.KG.
We reserve the right to make technical modifications.
The manufacturer accepts no liability for damage to property or pecuniary damages arising due
to minor defects of the product or documentation, e.g. print or spelling errors, and for those not
caused by intention or gross negligence of the manufacturer.
Dallmeier electronic GmbH & Co.KG
Cranachweg 1, D-93051 Regensburg, Germany
www.dallmeier.com
[email protected]
All trademarks identified by ® are registered trademarks of Dallmeier electronic.
All trademarks identified by *) are trademarks or registered trademarks of the following owners:
Adobe and Flash of Adobe Systems Incorporated headquartered in San Jose, California, USA
IBM of International Business Machines Corporation headquartered in Armonk, New York, USA
Microsoft, ActiveX, DirectX, Internet Explorer, Windows and Windows Vista of Microsoft Corporation headquartered in Redmond,
Washington, USA
Third-party trademarks are named for information purposes only.
Dallmeier electronic respects the intellectual property of third parties and always attempts to ensure the complete identification of third-party
trademarks and indication of the respective holder of rights. In case that protected rights are not indicated separately, this circumstance is
no reason to assume that the respective trademark is unprotected.
Table of contents
1
Introduction....................................................................................................6
1.1
Validity..............................................................................................................6
1.2
Documents.......................................................................................................6
1.3
Conventions.....................................................................................................6
2
Safety instructions........................................................................................8
3
General notes...............................................................................................10
3.1
Scope of delivery...........................................................................................10
3.2
Transportation and packaging.......................................................................10
3.3
Appropriate use.............................................................................................10
3.4
Performance features....................................................................................10
3.5
Warranty........................................................................................................11
3.6
Approvals/Certifications.................................................................................11
4
Requirements...............................................................................................12
4.1
General..........................................................................................................12
4.2
Power supply.................................................................................................12
4.3
Outdoor..........................................................................................................12
5
Views and connection assignment............................................................13
5.1
Views.............................................................................................................13
5.2
Connection assignment.................................................................................14
6
Installation and commissioning.................................................................15
7
Connection and login..................................................................................16
7.1
System requirements.....................................................................................16
7.2
IP address......................................................................................................16
7.3
Connection.....................................................................................................17
7.4
Login..............................................................................................................18
8
Basic settings..............................................................................................21
8.1
Language.......................................................................................................21
8.2
System time...................................................................................................21
8.2.1
Manual configuration.....................................................................................22
8.2.2
Time server....................................................................................................22
8.3
Camera name................................................................................................23
8.4
User management.........................................................................................23
8.4.1
Login mode....................................................................................................23
8.4.2
User groups...................................................................................................24
8.4.3
User...............................................................................................................24
8.4.3.1
Define a user.................................................................................................24
8.4.3.2
Edit user.........................................................................................................25
8.4.4
Rights.............................................................................................................25
9
Network.........................................................................................................28
9.1
Basic settings.................................................................................................28
9.1.1
Manual configuration.....................................................................................29
9.1.2
DHCP.............................................................................................................29
Delete alarm host entry..................................................................................40
9.3
Video streaming.............................................................................................41
9.3.1
Transfer protocol and format..........................................................................41
9.3.2
Transfer method.............................................................................................42
9.3.3
TTL.................................................................................................................43
9.4
IP-Finder........................................................................................................43
9.5
Camera protocol............................................................................................44
10
Video.............................................................................................................45
10.1
Video standard...............................................................................................45
10.2
Video settings................................................................................................45
10.3
Encoder settings............................................................................................46
10.3.1
Encoder 1......................................................................................................46
10.3.2
Encoder 2......................................................................................................48
10.4
Audio..............................................................................................................49
11
Motion detection..........................................................................................50
11.1
SmartFinder...................................................................................................51
11.2
Active areas...................................................................................................52
12
Interfaces......................................................................................................54
12.1
Serial interface...............................................................................................54
12.2
Relays............................................................................................................54
12.3
Data display...................................................................................................55
12.3.1
Filter...............................................................................................................55
12.3.2
Position..........................................................................................................56
13
Service and info...........................................................................................58
13.1
Event log........................................................................................................58
13.2
Configuration file............................................................................................58
13.2.1
Download.......................................................................................................58
13.2.2
Upload...........................................................................................................59
13.2.2.1
Configuration recovery...................................................................................59
13.2.2.2
Configuration transfer to several devices......................................................59
13.3
Info.................................................................................................................61
13.4
MAC address.................................................................................................61
13.5
Factory settings.............................................................................................62
13.6
Activations.....................................................................................................62
14
Image transmission.....................................................................................63
14.1
Web browser..................................................................................................63
14.2
RTSP application...........................................................................................63
Analogue video preview output......................................................................66
16.2
Serial interface...............................................................................................66
17
Technical data..............................................................................................67
18
Technical drawings......................................................................................68
This document applies to the audio and video streamer MicroStreamer-PoE.
The descriptions in this document are based on the software version 2.4.0.
Pictures in this document may differ from the actual product.
1.2
Documents
Commissioning
The document entitled “Commissioning” contains the most important steps for the connec
tion and commissioning of the device.
Installation and Configuration (this document)
The document entitled “Installation and Configuration” contains detailed descriptions of
the installation, connection, commissioning and configuration of the device. Safety instruc
tions, general notes and technical data are additionally provided.
The target audience is exclusively specially trained and authorized professionals (instal
lers).
1.3
Conventions
This document contains various warning words and symbols that indicate potential sources
of danger.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result
in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
NOTICE
NOTICE indicates practices for preventing property damage, incorrect con
figurations or faulty operations.
Instructions are indicated by arrows ().
Expressions in bold/italics generally indicate a control element on the device (switches or
labels) or on its user interface (buttons, menu entries).
Paragraphs in italics provide information on basic principles, special features and efficient
procedure as well as general recommendations.
Only use this unit if it is technically in proper working order, to the intended purpose and
while keeping safety and potential dangers in mind.
Qualified personnel
Installation, mounting, connection, commissioning and configuration of the unit may only
be carried out by qualified personnel. This also applies to the maintenance, testing and re
pair, whereat the regulations of the DIN VDE 0701 series of standards (repair, modification
and inspection of electrical appliances) must be followed.
Regulations
The use of video and audio surveillance systems in general is strictly regulated. Inform
yourself about the applicable laws and regulations regarding data, working and environ
mental protection before using the unit and ensure compliance with them.
System components
Only use internal components that have been tested and approved by Dallmeier. Inappro
priate internal components can cause malfunctions, damages and data loss and can result
in loss of warranty.
Modifications
Do not make any modifications to the hardware or software that has not been tested and
approved by Dallmeier. Inappropriate modifications can cause malfunctions, damages and
data loss and can result in loss of warranty.
Documentation
Carefully and completely read the documents included in delivery. Always observe the
contained instructions, notes and warnings.
Condensation water
If the unit is brought from a cold to a warm environment, resulting condensation water
can cause malfunctions and damages. In this case wait (up to 8 hours) until the unit has
reached room temperature before commissioning.
Operating conditions
Unfavourable operating conditions can shorten the life of the unit and can cause malfunc
tions, damages and data los s and can result in loss of warranty. Observe the specifications
given in the technical data, the operating condition requirements and the maintenance
instructions.
Shocks
Shocks can cause malfunctions and damages. The unit may not be moved while in ope
ration.
Foreign bodies
If objects or liquids get into the unit, immediately disconnect it from the power supply (pull
out the power plug). Contact the sales partner responsible for your area.
If you notice burnt smell or formation of smoke from the unit, immediately disconnect it from
the power supply (pull out the power plug). Contact the sales partner responsible for your
area.
Opening
The housing of the unit may only be opened by qualified personnel for inspection, mainte
nance and repair.
Disposal
Disconnect the unit from the power supply. Remove all connected devices. Return the unit
to your respective sales partner.
Scope of delivery
Included in the standard scope of delivery is:
1× MicroStreamer-PoE
1× 2-pole Weidmüller connector
1× Video adapter cable (2.5 mm phone jack/BNC)
1× Documentation “Installation and Configuration” (CD)
1× Documentation “Commissioning” (in print)
The scope of delivery may differ depending on the ordered equipment, the device variant
or the country of destination.
The functional range of the device depends on the ordered equipment or device variant
and may differ from this document’s content. Certain functions and features may require an
activation that is subject to costs.
3.2
Transportation and packaging
Store the original packaging for transportation at a later date. Dallmeier electronic is not
responsible for damage resulting from unprofessional/improper transportation. The goods
should only be shipped in their original packaging.
If the original packaging is no longer available, ensure that the packaging used sufficiently
protects the unit against damage, moisture, heat and cold.
3.3
Appropriate use
The MicroStreamer-PoE is a 1 channel audio and video streamer with a very compact
casing. It is able to receive and encode analogue audio and video signals and transmit the
resulting data in real-time via an Ethernet network (unicast or multicast) as a stream.
It can be operated via PoE (Power over Ethernet, Class 0) or at 24 V AC.
3.4
Performance features
• 1× analogue video channel
• Simultaneous encoding and streaming
• Video compression: MPEG-2/-4, MJPEG
• Audio compression: MPEG-1 Layer 2
• Integrated Dallmeier Image Optimiser for perfect image quality, even under adverse ligh
ting conditions
• Bit rate (constant or dynamic) up to 16 Mbps
• Resolution up to D1
• Frame rate up to 25 fps at all resolutions
• Configuration with web browser via Ethernet
• Evaluation with SeMSy® or PView via Ethernet
• Integrated motion detection with selectable sensitivity
• Recording with various Dallmeier recorders
• Integrated 64 MB video buffer
For detailed information see chapter “Technical data” on page 67.
3.5
Warranty
The terms and conditions valid at the signing of the contract shall apply.
3.6
Approvals/Certifications
Following approvals/certifications were valid at the time of document compilation.
Refer to www.dallmeier.com for possible updates.
• CE
• DIN EN 50130-4 compliant
The device is designed for indoor use. If used outdoors, the device has to be mounted into
a corresponding weather-proof housing (ventilated, temperature-controlled).
4.1
General
Unfavourable local conditions may shorten the life of the product and can cause malfunc
tions or damages.
¾
Do not install/operate the device in places
• with large scale dust and dirt.
• with steam or oil vapors (e.g. kitchen).
• with direct sunlight.
• strong heat emission (e.g. radiator).
• with improper ambient temperatures.
• near sources of strong radiation (e.g. radio transmitters, magnetic fields).
• with corrosive surroundings (e.g. gases, salt water).
• insufficient air ventilation (e.g. closed cabinet).
4.2
Power supply
The device can be operated via PoE (Power over Ethernet, Class 0) or at 24 V AC.
¾
Ensure that the existing network supports the PoE standard IEEE 802.3af if you want to
supply the device with power over Ethernet.
4.3
Outdoor
If used outdoors, the device has to be mounted in a weather-proof housing. Note that direct
insolation can cause very high temperatures inside the housing. In this case it is absolutely
necessary to use a ventilated, temperature-controlled metal weather-proof housing and a
sunshield if required.
To ensure optimal heat conduction, a metal carriage should always be used if the device is
mounted in a (weather-proof) housing.
Views and connection assignment
5.1
Views
Fig. 5-1 Front view
A Status LED
B Error LED
C ¼" tripod socket (on top and bottom side)
D Video IN (BNC socket, CVBS)
A
B
C
D
C
Fig. 5-2 Housing back side
E Power input terminal 24 V AC
F Power LED
G Analogue video preview output (2.5 mm phone jack)
H Audio IN (3.5 mm phone jack)
I
LAN port (RJ45, 10/100 Mbps, PoE conformity IEEE 802.3af)
J Serial interface (RS485, 2-pole Weidmüller connector)
For pinout information see chapter “Pin assignment” on page 66.
G
H
I
E
J
F
Installation and commissioning
The MicroStreamer-PoE can be installed on ceiling/wall brackets or freely positioned. How
ever, it must be ensured that the connection panel is freely accessible.
WARNING
Device falling off
Danger of injury
¾
Ensure that the device is securely positioned or mounted.
Electric shock hazard
Danger of death or serious injury
¾
Disconnect the power supply unit from the mains socket before connect
ing the device.
Danger of death from lightning strike
¾
Do not connect the video cable during a thunderstorm.
NOTICE
Possible damage to the device caused by inappropriate mounting equip
ment or incorrect installation.
¾
The length of the tripod screw must not exceed 7 mm.
¾
Pay attention to the manufacturer’s documentation when installing the
device into a weather-proof housing.
¾
If required, mount the MicroStreamer-PoE on a ceiling/wall bracket using the ¼" tripod
socket (C) and an appropriate tripod screw.
¾
Connect the analogue camera with a coaxial video cable to the BNC socket (D).
¾
Connect the MicroStreamer-PoE via LAN port (I) to the network.
¾
For video preview purposes, connect the delivered adapter cable to the analogue video
preview output (G) and a CVBS monitor.
If Power over Ethernet (PoE) is NOT available, proceed as follows:
In order to comply with the UL requirements, you have to use a UL-certified, limited power
source (LPS) Class 2 power supply unit.
¾
Connect the MicroStreamer-PoE via power input terminal (E) to an appropriate power
supply unit.
¾
Connect the power supply unit to the mains socket.
The Power LED (F) illuminates and the MicroStreamer-PoE boots up.
The MicroStreamer-PoE can be configured via network after approx. 45 seconds.
Connection and login
The configuration of the device is carried out with a PC/web browser via the local area
network (LAN).
Alternatively, the PC can be directly connected to the device via an Ethernet crossover
cable.
7.1
System requirements
To configure the device with live video display, the PC must meet the following minimum
system requirements:
Computer
IBM*)-PC compatible
Processor (CPU)
1.3 GHz
Random access memory (RAM)
256 MB
Operating system
Microsoft*) Windows*) 2000
Microsoft Windows XP
Windows Vista*)
each with latest service pack
Web browser
Microsoft Internet Explorer*), latest version
Graphics card
DirectX*) 9.0 compatible
Ethernet
100 Mbit/s
Software
Adobe*) Flash*) Player, latest version
Dallmeier control for ActiveX*), latest version
Note that
• a more powerful PC is required if several devices are configured with live video display
simultaneously.
• a DirectX compatible graphics card and the Dallmeier control for ActiveX are not requi
red for the configuration without live video display.
• the Dallmeier control for ActiveX can be downloaded from the Dallmeier Partner Fo
rum.
• the Dallmeier control for ActiveX can be automatically downloaded via Internet after
the connection to the device (only with Microsoft Internet Explorer and if it is not alrea
dy installed).
• the configuration without live video display may be possible with any operating system
and web browser. However, the Adobe Flash Player is always required for the confi
guration.
7.2
IP address
The factory default IP address of the device is 192.168.2.28.
To find out the current IP address of the device, proceed as follows:
¾
Ensure that the device is disconnected from the power supply.
Connect the video preview output of the device with an adapter cable to a CVBS monitor.
¾
Switch on the monitor.
¾
Connect the device to the power supply.
¾
When the device starts, wait for approximately one minute.
The current IP address of the device is displayed for approximately 30 seconds on the
monitor.
7.3
Connection
¾
Ensure that the PC/web browser can establish a connection to the device via Ethernet.
¾
Start the web browser.
¾
Enter the IP address of the device into the address bar of the web browser.
¾
Confirm the input.
The connection to the device is established.
The graphical user interface (GUI) of the live mode is displayed.
A
B
D
C
E
F
Fig. 7-1 Live mode with adjustable video resolution
A Hide/show title bar
B Switch between live and configuration mode
C Live video
D Adjust video resolution
E IP address of device
F Log out of configuration mode
Note the explanations below.
¾
Hide the title bar (A) if required.
¾
Activate the Networks with routers checkbox if required.
¾
Adjust the live video resolution (D) if required.
This resolution setting only affects the live video display in the web browser and is not re-
lated to the encoder settings.
Network with routers
If the network connection to the device is established via a router/gateway with NAT (Net
work Address Translation) function, the live video may not be shown in certain circumstan
ces. In this case, two solutions are available:
The router/gateway has to be configured for a correct address translation of data packets
sent by the User Datagram Protocol (UDP). UDP is by default used by the streaming func
tion of the device.
An easier solution is to activate the Networks with routers (NAT) checkbox. In this case,
the device switches the protocol of the streaming function to the Transmission Control Pro
tocol (TCP). To receive the data packets, the port 30000 for the DaVid Protocol1 and port
80 for the Hypertext Transfer Protocol (HTTP) must be open.
Note that at data transmission over TCP
• normally no packet loss (lack of images) occurs.
• short-term peaks in network traffic may occur.
• low delays may occur.
The “Networks with routers (NAT)” function does not affect the “Video streaming” function
(see section “Video streaming” on page 41).
7.4
Login
The graphical user interface of the configuration mode is displayed after the successful
identification as authorised user.
Note that the factory default password of user group Group 1: admin is “3”.
NOTICE
Risk of misuse by unauthorized users!
¾
Change the factory default password as soon as possible.
¾
Click CONFIG in the user interface of the live mode.
1 Dallmeier Video Protocol
The login dialogue is displayed.
Fig. 7-2
¾
Enter the Username if required.
¾
Enter the Password.
¾
Confirm with OK.
The graphical user interface of the configuration mode is displayed.
D
F
G
H
A
B
C
E
Fig. 7-3 Configuration mode
A Hide/show title bar
B Switch between live and configuration mode
C Disable/enable live video display
D Live video
E Configuration menu
F Configuration dialogues
G IP address of the device
H Log out of configuration mode
• the live video display in the configuration mode can be disabled if only a low bandwidth
is available.
• a new login is required after 5 minutes without user action.
The basic settings and the user management are integrated in the Common settings
menu.
8.1
Language
The graphical user interface can be displayed in various languages.
¾
Open the User interface dialogue via Common settings > User interface ....
Fig. 8-1
¾
Set a Language.
¾
Confirm with OK.
8.2
System time
The system time can be set manually or synchronized with a UTC time server. The time
zone must be set in both cases.
¾
Open the Time settings dialogue via Common settings > Time ....
¾
Select the Time zone tab.
Fig. 8-2
¾
Set the Time zone.
¾
Confirm with OK.
Note that no manual configuration is possible if the UTC time server synchronization is
enabled.
¾
Select the Date/Time tab.
Fig. 8-3
¾
Set the Date.
¾
Set the Time.
¾
Confirm with OK.
8.2.2
Time server
Note that the time server must always be accessible via the network.
¾
Select the Time server tab.
Fig. 8-4
¾
Enter the IP address of the time server.
¾
Activate the Use time server checkbox to enable the UTC time server synchronization.
¾
Confirm with OK.
The camera can be assigned a name which then can be displayed in an external applica
tion (e.g. PView2).
¾
Open the Camera name dialogue via Common settings > Camera name ....
Fig. 8-5
¾
Enter a name.
¾
Confirm with OK.
8.4
User management
The user management allows the definition of various access and configuration rights for
three separate user groups. In addition, several users can be assigned to each user group
if required.
8.4.1
Login mode
The configuration of the device is only possible after a successful authentication as a valid
user. The login mode defines the type of authentication.
Mode
Type
Group login
Group password
User login
User name + user password
or
Group password
The authentication with the group password is also possible in the “User login” mode.
¾
Open the Login options dialogue via Common settings > User management > Login
options ....
Fig. 8-6
2 Dallmeier Video Management Software
Set the Login mode.
¾
Confirm with OK.
8.4.2
User groups
The group names of the three user groups can be changed.
Note that,
• the factory default password of Group 1: admin is “3”.
• the factory default password of Group 1: admin must be changed for security reasons.
• Group 2: user and Group 3: guest are defined without a factory default password.
• a login of Group 2: user and Group 3: guest is only possible after a password is
defined.
¾
Open the User groups dialogue via Common settings > User management > User
groups ....
Fig. 8-7
¾
Select the tab of the relevant group.
¾
Set a new Group name if required.
¾
Enter a New password.
¾
Repeat the new password in the Confirm password field.
¾
Finally confirm with Apply.
8.4.3
User
In the “User login” mode, individual users can be assigned to the three user groups.
8.4.3.1
Define a user
¾
Ensure that the Login mode is set to User login.
¾
Open the User groups dialogue via Common settings > User management > User
groups ....
Select the tab of the relevant group.
¾
Click New.
The New user dialogue is displayed.
Fig. 8-9
¾
Enter a new User name.
¾
Enter a New password.
¾
Repeat the new password in the Confirm password field.
¾
Finally confirm with OK.
8.4.3.2
Edit user
¾
Ensure that the Login mode is set to User login.
¾
Open the User groups dialogue via Common settings > User management > User
groups ....
¾
Select the tab of the relevant group.
¾
Select the relevant user from the users list.
¾
Edit or Delete the user by clicking the related button.
8.4.4
Rights
The three user groups, and so the assigned users, can be granted individual rights. Addi
tionally the general public (user group anonymous) can be granted or denied access to
certain types of live images.
• the rights of the Group 1: admin can not be restricted.
• certain rights can not be set to all permission levels.
• certain rights are partially or fully relevant for external applications (e.g. DaVid) only.
¾
Open the Rights configuration dialogue via Common settings > User management
> Rights ....
Fig. 8-10
The various rights are displayed each in a line. The permission level of each user group is
displayed with a symbol in the corresponding column.
Symbol
Tool tip
Right
allow
The dialogue will be displayed.
The settings can be changed.
The function can be used.
allow read only
The dialogue will be displayed.
The settings can not be changed.
deny
The dialogue will not be displayed.
The settings can not be changed.
The function can not be used.
Find the relevant right (line).
¾
Change the permission level with a click on the symbol in the column of the relevant
group.
¾
Proceed as described above for all rights and groups.
¾
Finally confirm with OK.
The network settings of the device can be configured manually or automatically assigned
by a DHCP (Dynamic Host Configuration Protocol) server.
In order to avoid network conflicts, you should clarify if intended network settings are per-
mitted. In particular, the allocation of an already used IP address may result in malfunctions.
¾
Open the Network settings dialogue via Network > Basic settings ....
Fig. 9-1
Default settings
Connection type:
automatic
DHCP:
deactivated
Hostname:
ipcam
IP address:
192.168.2.28
Netmask:
255.255.255.0
Gateway:
192.168.2.1
Allow IP-Finder remote network configuration:
activated
NOTICE
Incorrect settings may result in the device being no longer available via
the network.
¾
For troubleshooting purposes, write down the MAC address and all new
settings before changing the configuration.
¾
Note the explanations below.
¾
Select the transfer rate and the duplex mode from the drop-down list Connection type.
The “Connection type > automatic” (Autonegotiation) is suitable for most applications.
If no DHCP server is available in the local area network (LAN) or if you want to assign the
network settings manually, proceed as follows:
¾
Pay attention to the designated and valid IP address ranges in your network.
¾
Ensure that the DHCP checkbox is deactivated.
¾
Enter the IP address you want to assign to the device.
¾
Enter the Netmask.
¾
Enter the Gateway address.
¾
Deactivate the Allow IP-Finder network configuration3 checkbox if not required.
¾
Finally confirm with OK.
The “Hostname” is for internal purposes only. A modification is not necessary.
The connection to the device is terminated and the new network settings are assigned.
9.1.2
DHCP
To automatically assign the network settings by a DHCP server, proceed as follows:
¾
Ensure that an active DHCP server is available in the local area network (LAN).
¾
Activate the DHCP checkbox.
¾
Deactivate the Allow IP-Finder network configuration checkbox if not required
¾
Finally confirm with OK.
The connection to the device is terminated and the new network settings are assigned by
the DHCP server (pay attention to the lease duration).
The newly assigned IP address can be determined by the MAC address of the device with
the IP-Finder or at the DHCP server.
The IP-Finder must be executed in the same LAN where the device is located.
3 IP-Finder: Dallmeier software for determination and configuration of network-compatible Dallmeier devices
The device provides event-triggered messaging functions for text notification, e-mail mes
saging and FTP image upload to various alarm hosts.
Note that the device and the relevant alarm host must be located in the same LAN or must
be able to communicate via a gateway.
¾
Click Network > Alarm hosts.
If no alarm host has yet been set, only the New ... item is displayed.
¾
Click Network > Alarm hosts > New ....
The configuration menu is expanded with the Alarm host 1 item and the related dialogue
is displayed.
To edit an already set alarm host, click the related item in the configuration menu.
9.2.1
Settings
In the Settings tab the alarm host settings are configured.
Fig. 9-2
¾
Note the explanations below.
¾
Select the Type of the transfer protocol.
¾
Enter the Name and the IP address of the alarm host.
¾
Activate the active checkbox to enable event-triggered alarm messaging for the current
ly selected alarm host.
¾
Configure all necessary settings of the selected transfer protocol.
¾
Confirm with OK.
The alarm host name in the configuration menu is updated automatically after saving.
The alarm/event messages are sent to the alarm host via DaVid protocol.
Note that a DaVid Protocol capable software for message evaluation (e.g. PGuard advan
ce4) must be running on the relevant alarm host.
SMTP server
The alarm/event messages are sent as e-mails via SMTP to the alarm host (SMTP server)
which then may forward them to several e-mail recipients.
Depending on the used SMTP server and its configuration the sender is arbitrary or a
SMTP authentication is required.
Fig. 9-3
¾
If necessary, enter the Username and the Password for the SMTP authentication.
¾
Enter the Sender.
¾
Enter the e-mail addresses of the Recipients (separated by semicolon) to which the
SMTP server should forward the e-mail.
¾
Enter the Subject and the Message of the e-mail.
4 Dallmeier evaluation and management software for messages
The following variables can be used for the e-mail subject and the e-mail message:
%ALARMTYPE%
Alarm/event type
%ALARMHOSTNAME% Name of the alarm host
%CAMERANAME%
Name of the device
%ALARMTIME%
Date and time the alarm/event is triggered
%DEVICEIP%
IP address of the device
¾
Activate the add image as attachment checkbox to attach the current live image pre
sent at the moment when the event is triggered.
¾
Select Encoder 2 or Encoder 1 from the drop-down list Image source to define the
source of the live image which should be attached.
“Encoder 2” is deactivated by default. To attach the current live image of “Encoder 1” the
“Encoder mode > MJPEG” must be set (see section “Encoder settings” on page 46).
¾
Click Test to send a test e-mail.
FTP server
The current live image, present at the moment when the event is triggered, is uploaded to
the alarm host (FTP server).
Fig. 9-4
¾
Enter the Username and the Password for the FTP authentication.
¾
Enter the full path to the directory where the live image should be saved to into the Fol
der path field.
Ensure that read and write permissions are set for the specified directory and enough free
disk space is available.
¾
Enter the Filename the live image should be saved with.
Select the Filename definition:
• Filename + .jpg
The existing image will be overwritten.
• Filename + number (ring) + .jpg
The oldest image will be overwritten after a certain number of saved images (Ringbuf
fer size).
• Filename + number + .jpg
Existing images will not be overwritten.
• Filename + date + .jpg
Existing images will not be overwritten.
¾
If necessary, enter the Ringbuffer size.
¾
Select Encoder 2 or Encoder 1 from the drop-down list Image source to define the
source of the live image which should be uploaded.
“Encoder 2” is deactivated by default. To attach the current live image of “Encoder 1” the
“Encoder mode > MJPEG” must be set (see section “Encoder settings” on page 46).
¾
Click Test to test the FTP image upload.
9.2.2
Messages
Depending on the selected transfer protocol type, various alarm/event types can be set for
alarm/event messaging:
¾
Select the Messages tab.
Fig. 9-5
¾
Select all relevant messages which should be sent out by activating the related check
box.
¾
If necessary, set the Interval of FTP image uploads (see below).
¾
Confirm with OK.
The interval option is helpful to reduce the number of FTP image uploads if lots of alarm/
events are triggered within a short time. The less the Duration (sec.) between two FTP
image uploads is set, the more the network utilization rate (traffic level, bandwidth con
sumption) may increase.
9.2.3
Scheduler
The scheduler function allows scheduling the messaging function.
Note that
• scheduler settings only apply to the currently selected alarm host.
• the minimum selectable period is 15 minutes.
• the week timer applies to the entire year if no exceptions are set.
9.2.3.1
Week timer
¾
Click Scheduler ....
The Week timer tab is displayed.
Fig. 9-6
Light gray areas in the week timer represent active periods.
During active periods the messaging function is enabled.
By default, the entire period in the week timer is active.
Select inactive periods
¾
Click inactive.
¾
In the week timer, click and hold the left mouse button and draw a rectangle over a
relevant period.
¾
Release the mouse button.
¾
Repeat the last two steps until all relevant inactive periods are selected.
Dark gray areas in the week timer represent inactive periods.
During inactive periods the messaging function is disabled.
In the example shown (Fig. 9-7) the period on Monday from 02:00 to 07:15 am is inactive.
During this period no messages are sent out.
¾
Confirm with OK if you do not want to make any additional settings.
Delete inactive periods
¾
Click active.
¾
In the week timer, click and hold the left mouse button and draw a rectangle over an
inactive period.
¾
Release the mouse button.
¾
Repeat the last two steps until all relevant inactive periods are deleted.
It is also possible to delete sections (at least 15 minutes) between inactive periods.
¾
Confirm with OK if you do not want to make any additional settings.
For days with deviations, exceptions can be defined.
Note that exceptions will overwrite the settings of the entire relevant day in the week timer.
¾
Select the Exceptions tab.
Fig. 9-8
¾
Click New ....
The Calendar is displayed.
Fig. 9-9
¾
Select a date.
¾
Confirm with OK.
The selected date is added to the exceptions list.
Fig. 9-10
Dark gray areas in the timetable represent inactive periods.
During inactive periods the messaging function is disabled.
By default, the entire period (24 hours) in the timetable is inactive.
Select active periods
¾
Click active.
¾
In the timetable, click and hold the left mouse button and draw a rectangle over a rele
vant period.
¾
Release the mouse button.
¾
Repeat the last two steps until all relevant active periods are selected.
Fig. 9-11
Light gray areas in the timetable represent active periods.
During active periods the messaging function is enabled.
In the example shown (Fig. 9-11) the period from 02:00 to 06:00 am is active. During this
period messages are sent out.
¾
Confirm with OK if you do not want to make any additional settings.
Delete active periods
¾
Click inactive.
¾
In the timetable, click and hold the left mouse button and draw a rectangle over an
active period.
¾
Release the mouse button.
¾
Repeat the last two steps until all relevant active periods are deleted.
It is also possible to delete sections (at least 15 minutes) between active periods.
If the exception settings should also apply to other days, they can be can copied to another
date (see below).
¾
Confirm with OK if you do not want to make any additional settings.
9.2.3.3
Copy exceptions
¾
Select a date from the exceptions list.
¾
Click Copy ....
The Calendar is displayed.
Fig. 9-12
¾
Select the new date to which you want to copy the exception settings.
¾
Confirm with OK.
The new date with the copied exception settings is added to the exceptions list.
To delete exceptions, select the relevant date in the exceptions list and click “Delete”.
¾
Confirm with OK if you do not want to make any additional settings.
9.2.4
Copy
The copy function allows copying the saved settings to other alarm hosts entries.
¾
Click Network > Alarm hosts.
¾
Select a saved alarm host entry from the configuration menu.
The related dialogue is displayed.
Fig. 9-14
¾
Click Copy ....
The configuration menu is expanded with the name of the copied alarm host entry with the
addition (1) (represents copy 1) and the related dialogue of the copy is displayed.
Customize the relevant settings.
¾
Finally confirm with OK.
9.2.5
Delete alarm host entry
To delete an alarm host entry, proceed as follows:
¾
Click Network > Alarm hosts.
¾
Select the alarm host entry to be deleted from the configuration menu.
The related dialogue is displayed.
Fig. 9-16
¾
Click Delete.
The alarm host entry is deleted and its menu item removed from the configuration menu.
The video streaming function provides the streaming of audio and video data to the net
work without requesting the data actively with a RTSP (Real Time Streaming Protocol) or
DaVid Protocol capable client (e.g. Dallmeier recorder or PView).
Note that the format of the RTP payload to be transported must correspond with the encod
ing method.
For information about encoder settings see section “Encoder settings” on page 46.
¾
Open the Video streaming dialogue via Network > Video streaming ….
Fig. 9-17
¾
Note the explanations below.
¾
Select Encoder 1 or Encoder 2 from the drop-down list Input.
¾
Select the transfer protocol, format and method from the drop-down list Mode.
¾
Depending on the selected transfer method, enter the Multicast IP address or the De
stination IP address.
¾
Enter the port number of the service which should receive the data packets into the Port
(1024 … 65535) field.
¾
Enter the TTL value of IP packets into the TTL (0 …255) field.
¾
Confirm with OK.
9.3.1
Transfer protocol and format
The transfer protocol defines the communication rules for the exchange of the audio and
video data in the network.
The IP packets are transferred via UDP (User Datagram Protocol).
Note that
• UDP provides data transmission with a relatively low delay.
• packet loss (lack of images) may occur during transmission.
The transfer format defines the RTP payload to be transported.
The audio and video data is packetized for a MPEG-2 Program Stream.
The data must be encoded in MPEG2 format.
RTP/MPV
The video data is packetized for a MPEG-2 Video Stream by the Real-Time Transport
Protocol (RTP).
Audio data is not transferred.
The data must be encoded in MPEG2 format.
The packaging is based on the following standards:
RFC3550 - RTP: A Transport Protocol for Real-Time Applications
RFC3551 - RTP Profile for Audio and Video Conferences with Minimal Control
RFC2250 - RTP Payload Format for MPEG1/MPEG2 Video
RTP/MP4V-ES (RFC 3016)
The video data is packetized for a MPEG-4 Video Elementary Stream by the Real-Time
Transport Protocol (RTP).
Audio data is not transferred.
The data must be encoded in MPEG4 format.
The packaging is based on the following standards:
RFC3550 - RTP: A Transport Protocol for Real-Time Applications
RFC3551 - RTP Profile for Audio and Video Conferences with Minimal Control
RFC3016 - RTP Payload Format for MPEG-4 Audio/Visual Streams
RTP/MJPEG
The video data is packetized for a MJPEG Video Stream by the Real-Time Transport Pro
tocol (RTP).
Audio data is not transferred.
The data must be encoded in MJPEG format.
The packaging is based on the following standards:
RFC3550 - RTP: A Transport Protocol for Real-Time Applications
RFC3551 - RTP Profile for Audio and Video Conferences with Minimal Control
RFC2435 - RTP Payload Format for JPEG-compressed Video
9.3.2
Transfer method
The transfer method defines the distribution of audio and video data in the network.
Multicast
The data packets are transferred via point-to-multipoint connection to a group of receivers
(clients) including the specified IP multicast address and port number.
The packets have to be transferred only once, the distribution to the members of the group
is done for instance by specially configured routers.
A member of the group only receives the data packets if it is aware of the multicast IP
address and the appropriate application service is available with the specified port number.
IP multicast uses the address range from 224.0.0.0 to 239.255.255.255 (Class D).
Note that certain IP multicast address ranges are reserved for special purposes.
Unicast
The data packets are transferred via point-to-point connection to exact one receiver (client)
in the network including the specified destination IP address and port number.
The receiver only receives the data packets if the appropriate application service is availa
ble with the specified port number.
9.3.3
TTL
The TTL value (Time To Live) defines the lifetime of an IP packet.
Every router an IP packet passes through reduces the time to live value by one (1). If the
value is zero (0), the IP packet is discarded.
While preventing IP packets from endlessly circulating in the network due to routing errors,
this method stops IP packets from breaking through the limits of the LAN and being sent to
the WAN (TTL = 1).
According to requirements a TTL value from 1 – 255 can be entered. When entering 0
(zero), the default values are used (TTL = 1 for multicast, TTL = 64 for unicast).
9.4
IP-Finder
The access to the device with the IP-Finder can be restricted.
¾
Open the Network settings dialogue via Network > Basic settings ….
Fig. 9-18
¾
Deactivate the Allow IP-Finder network configuration checkbox to protect the net
work settings of the device from being configurable via the IP-Finder.
¾
Confirm with OK.
If required from external devices/applications, the camera protocol can be specified.
¾
Open the Camera protocol dialogue via Network > Camera protocol ….
Fig. 9-19
Default settings
Manufacturer:
Dallmeier
Type:
MicroStreamer
¾
If required, enter the Manufacturer and the Type of the camera protocol.
¾
Confirm with OK.
Countries and territories use different broadcasting televisions systems. To ensure a cor
rect video signal transmission, the appropriate video standard for your country must be set
at the device.
¾
Open the Video standard dialogue via Video > Video standard ….
Fig. 10-1
Note that this dialogue may be locked by external devices/applications.
¾
Select a Standard.
¾
Confirm with OK.
10.2
Video settings
The Video settings dialogue provides the user-defined image processing adjustment of
the incoming video signal.
These settings have a direct effect on the recording, not just on the image display on the
evaluation station’s monitor.
¾
Open the Video settings dialogue via Video > Video settings ....
The Video settings dialogue is displayed.
Fig. 10-2
Note the explanations below.
¾
Adjust all necessary settings.
¾
Confirm with OK.
¾
Check the image in the live video frame in the bottom left of the configuration user inter
face (if active).
¾
If necessary, readjust the settings and confirm with OK again.
¾
Finally close the dialogue with Cancel.
You can restore the factory sensor settings at any time by clicking “Default”.
3dVNC Noise filter
The digital 3dVNC Noise filter provides the reduction of image noise.
In contrast to analogue filters, the image noise is not reduced by smoothing the image. The
temporal 3D filter compares individual pixels in sequential images and identifies typical
fluctuations in the colour and brightness values. Only when the fluctuation exceeds a set
limit, the pixel will be filtered out.
Note that setting the filter for fast-moving objects may result in motion blur. This drawback
is due to technical reasons and cannot be completely avoided.
10.3
Encoder settings
The audio and video encoding is configured in the Encoder settings dialogue.
This dialogue may be locked by external devices/applications.
10.3.1
Encoder 1
¾
Open the Encoder settings dialogue via Video > Encoder settings ....
The Encoder 1 tab is displayed.
Fig. 10-3
¾
Note the explanations below.
¾
Select the encoding standard from the drop-down list Encoder mode.
¾
Select the frame rate from the drop-down list Frames/Second.
¾
Select the Resolution (width × height in pixels).
¾
Select the Deinterlacing mode.
¾
Select the Bitrate.
Select the Bitrate mode.
¾
Select the GOP-size (only with MPEG).
¾
If required, activate the B-Frames checkbox (only possible at a GOP-size > 6).
Frames/Second
The frame rate (value in fps) defines the number of consecutive frames produced per se
cond. The higher the frame rate is, the smoother the video playback.
Note that audio encoding is only available at a frame rate of 25 fps (PAL) or 30 fps (NTSC).
Bitrate
The bit rate refers to the number of bits per second used to encode the video. The more bits
are used to represent the video data per second, the higher the quality is.
Low bit rate
High image compression
Small data volume
Poor image quality
High bit rate
Low image compression
Large data volume
High image quality
The most requirements in surveillance systems are met with a bit rate between 4 and 6
Mbps.
Bitrate mode
The bit rate mode allows configuring a constant or a variable bit rate for the video encoding.
The “variable” mode changes the bit rate in accordance with the activity (changes) in the
image. The allowed bit rate variations can be limited by the according percentage value.
Example:
With a set bit rate of 4 Mbps and a bit rate mode of “variable 50 %”, the bit rate can vary
from 6 to 2 Mbps.
Variable bit rates make better use of the available hard disk space.
GOP-size
GOP (Group Of Pictures) is a variable for specifying how images are used to generate the
MPEG data stream.
The higher the GOP-size is, the better the image quality, although a higher GOP-size will
also result in an increase in the delay. A GOP-size between 6 and 15 generally represents
a good compromise enabling good image quality with high compression.
A GOP-size of 1 denotes a low compression factor and should only be used for special
applications (e.g. multiplex mode).
As from a GOP-size of 6 the use of B-Frames can be enabled by checking the appropriate
checkbox. This setting also has a positive effect on the image quality but again results in
a slight delay.
GOP-sizes greater than 15 belong to the extended GOPs.
Reverse playback has limited quality (frame drops) with extended GOPs (> 15).
Deinterlacing
The aim of this function is to enhance the image quality by computationally eliminating the
so-called interlace effect, which may occur after merging two fields into a frame, from the
frame.
However, whether a higher quality can be achieved depends on many factors such as the
speed of the motions in the image or the type of output device on the decoder side (digital
or analogue monitor).
It is therefore not possible to provide a general recommendation to activate or deactivate
this function. Therefore, we do recommend that you test the output on the monitor/decoder
after the function has been configured.
For this purpose, select a playback scene typical for the camera concerned. If the interlace
effect can be detected with moving objects i.e. if moving edges are slightly displaced bet
ween two fields, this effect can be reduced by activating Deinterlacing.
However, the playback thus may be jumpy. In this case the deactivation of this function
may, in certain circumstances, result in a smoother playback.
Note that Deinterlacing is only possible with a resolution of HalfD1 or higher.
10.3.2
Encoder 2
“Encoder 2” only encodes images to MJPEG format.
The images encoded by Encoder 2 can be used for video streaming, accessed via RTSP
and sent to an alarm host.
¾
Select the Encoder 2 tab.
Fig. 10-4
“Encoder 2” is deactivated by default.
¾
Activate the use encoder checkbox if required.
¾
Select the frame rate from the drop-down list Frames/Second.
¾
Select the Resolution (width × height in pixels).
¾
Confirm with OK.
The audio bit rate setting allows you not only to control the audio quality, but also the
amount of required hard disk space to a certain extent. The higher the audio bit rate, the
better the audio quality. A higher bit rate, however, requires more hard disk space than a
lower bit rate.
¾
Select the Audio tab.
Fig. 10-5
Note that audio encoding is only available at a frame rate of 25 fps (PAL) or 30 fps (NTSC).
¾
Select the Audiobitrate.
¾
Confirm with OK.
11 Motion detection
The motion detection function analyses if and how much two consecutive images differ
from each other. If the difference satisfies the set criteria, the function assumes a motion
event.
Actions/functions which are based on motion events:
• Recording
• Event recording
• SmartFinder5
• Message transfer to alarm host
This dialogue may be locked by external devices/applications.
The motion detection settings can be tested with the motion indicator in the live video
frame.
¾
Click Motion detection … in the configuration menu.
Fig. 11-1
¾
Note the explanations below.
¾
Set the Level SAD.
¾
Select the Sensitivity.
¾
Confirm with OK.
Level SAD
Every image is split into sectors, with each being analysed for differences compared to the
previous image. The Level SAD (SAD = Sum of absolute differences) defines the minimum
level of alteration necessary to mark an image sector as altered.
200
Major changes required
10
Minor changes required
5 Dallmeier system for the intelligent search of motion events within an image
The Sensitivity defines the maximum number of objects (linked changed image sectors)
that may exist in the entire image. If the number of objects is exceeded, the already detec
ted event will be discarded.
The limitation of the number of objects prevents motion event triggering with lots of small
changes (e.g. image noise or snowfall).
very sensitive 1 object
few events
sensitive
2 objects
normal
3 objects
less sensitive
4 objects
least sensitive 5 objects
lots of events
off
Function switched off
11.1
SmartFinder
To enable the intelligent search for motion events within an image with a Dallmeier recor
der, SmartFinder has to be activated.
¾
Activate the Enable SmartFinder checkbox.
Fig. 11-2
¾
Note the explanations below.
¾
Select the Sensitivity.
¾
Enter the Fade Out Time (s) (value in seconds).
¾
Confirm with OK.
Level SAD
Function as described above but the value is predetermined by the system.
Fade Out Time (s)
This value in seconds defines how long an object (linked changed image sectors) is valid.
If another object is detected in the same area during this period, it will not be assessed as
a new event but will be discarded.
This setting allows reducing the number of events triggered by the repeated motion of the
same object.
Example:
0
Every object is a new event
Very large number of events
Sensitivity
This function checks the extent to which an old (still valid) object and a new object overlap.
If the non-overlapping area is larger than an (internally) set value, the new object will be
assessed as a new event.
This function therefore represents a refinement of the mechanism set by the fade out time.
very sensitive
Event even if non-overlapping area is small
Lots of events
…
least sensitive
Event only if non-overlapping area is very large
Few events
11.2
Active areas
The motion detection function is active in the entire image area by default.
In order to ignore motion events in certain areas, inactive areas can be defined.
The current video image is only displayed in the dialogue if “Encoder mode > MJPEG” is
set or “Encoder 2” is active (see section “Encoder settings” on page 46).
¾
Click Active areas.
The Active areas / Encoder 1 dialogue is displayed.
Fig. 11-3 Active areas (red)
Button Pencil: select active (red) areas
Button Eraser: select inactive (green) areas
To define inactive (green) areas, proceed as follows:
¾
Click the Eraser button.
¾
Move the mouse pointer over the image area, click and hold the left mouse button and
draw a rectangle over the relevant area.
¾
Release the mouse button.
¾
If necessary, repeat the last two steps until all inactive areas are selected.
¾
Confirm with OK.
Fig. 11-4 Inactive areas (green)
To define active (red) areas, proceed as follows:
¾
Click the Pencil button.
¾
Move the mouse pointer over the image area, click and hold the left mouse button and
draw a rectangle over the relevant area.
¾
Release the mouse button.
¾
If necessary, repeat the last two steps until all active areas are selected.
¾
Confirm with OK.
External devices, such as the RS485 contact interface, can be connected to the serial
interface.
The Crosslink functionality is only supported via the DaVid Protocol (e.g. with PView).
¾
Open the Serial port dialogue via Interfaces > Serial ....
Fig. 12-1
¾
In the Function field, select between Crosslink, Contact Interface (for the RS485 con
tact interface) or none.
The fields for Mode, Baud, Bits etc. are set to default values. However, the required set
tings depend on the external device you wish to use. See the manual supplied with the
external device for details of the required values.
¾
Click OK to apply your settings.
12.2
Relays
This dialogue allows the Contact OUT relays to be configured.
This function can be used with a RS485 contact interface only.
¾
Open the Relays dialogue via Interfaces > Relays ....
Select the Function in which case the relay should be switched.
To switch the relay in case of a camera failure, select the “Function > Error” and activate
the “Camera” checkbox.
Timer (Holding Time)
¾
Set the Timer to On to enable the relay activation timer (holding time).
¾
In the Time (sec.) field, enter the relay activation time in seconds.
Type
In the Type field, select whether the relay should act as make contact (NO - Normally
Open) or as break contact (NC - Normally Closed).
¾
Finally confirm with OK.
12.3
Data display
The data display function provides the embedding of data transferred from external de
vices/applications (via DaVid Protocol).
The embedded data is displayed in live mode of DaVid Protocol capable devices/appli
cations. A recording of the embedded data has to be configured separately. For detailed
information refer to the separate documentations.
12.3.1
Filter
The external transferred data can be filtered before embedding.
The filtering (selection) only takes effect on external sent data.
¾
Open the Data display - Filter dialogue via Interfaces > Data display > Filter ....
By default, no external transferred data is embedded.
To embed external transferred data, proceed as follows:
¾
Activate the Display active checkbox.
¾
Select the relevant data by activating the related checkbox.
¾
Select the Duration.
¾
Confirm with OK.
The external transferred data is embedded in the current image (frame) present at the mo
ment when the data is received and keeps embedded for the selected Duration (frames).
12.3.2
Position
The embedded data can be positioned for displaying in live mode with DaVid Protocol ca
pable devices/applications.
¾
Open the Data display - Position dialogue via Interfaces > Data display > Positi
on ....
Fig. 12-4
The right-hand side of the dialogue (blue rectangle with Dallmeier logo) represents a screen
for displaying live videos with full “PAL” or “NTSC” resolution.
The white lines illustrate the stylized graphical user interface (GUI) of a typical application
for displaying live videos.
The white rectangle with the yellow corner (in the bottom right) shows the display area of
the embedded data.
On the left-hand side of the dialogue the coordinates and dimensions of the display area
are displayed (values in pixels).
The coordinates refer to the top left corner of the display area.The display area can be
positioned by drag & drop.
Fig. 12-5
The display area can be resized by dragging its yellow corner (in the bottom right).
Fig. 12-6
An exact positioning and resizing is possible by using the corresponding input fields.
¾
Adjust all relevant settings.
¾
Confirm with OK.
13 Service and info
13.1
Event log
The device logs IP addresses of applications that temporarily blocked certain resources
of the device in a log file. The list of IP addresses is displayed in the Event log dialogue.
¾
Open the Event log dialogue via Service > Event log ….
Fig. 13-1
13.2
Configuration file
The configuration of the device can be exported to a file and thus be saved.
In addition to recover the configuration of the device that is currently connected, the confi
guration can also be transferred to several devices simultaneously.
13.2.1
Download
NOTICE
If the configuration file should be transferred to several devices, the Net
work settings must not be exported.
¾
Open the Configuration file management dialogue via Service > Configuration file
> Download ....
Fig. 13-2
Select all relevant settings which should be exported to the configuration file by acti
vating the related checkbox.
¾
Confirm with OK.
¾
Follow the instructions of the download dialogue and save the configuration file to a
data storage device.
The configuration file name contains the IP address of the related device.
13.2.2
Upload
The saved configuration file can be transferred to an individual device. This allows the re
covery of the configuration of the device that is currently connected.
In addition, the configuration file can also be transferred to several devices simultaneously.
This is a very effective method of configuring several devices identically in terms of certain
configuration groups.
13.2.2.1
Configuration recovery
To recover the configuration of an individual device, the connection to the device must be
established first (see section “Connection” on page 17).
¾
Open the Configuration file management dialogue via Service > Configuration file
> Upload ....
Fig. 13-3
¾
Click Browse….
¾
Select the relevant configuration file on your data storage device.
¾
Confirm with OK.
At the end of the transfer the list of transferred (or skipped) configuration settings is dis
played.
13.2.2.2
Configuration transfer to several devices
As a precondition all relevant devices must be located in the same LAN (with suitable
cabling and a separate IP address for each device). In addition, the access rights to all
devices must be identical (same user name and password).
Before the configuration file can be transferred, it must be saved as described above.
However, the configuration of the Network settings must not be included in the configu
ration file. If these settings were included, the same IP address would be transferred to
all devices. Since, however, every IP address in a LAN must be unique this would cause
massive problems in the network.
Ensure that the configuration of the Network settings is not transferred to
several devices.
To send the configuration file to several devices, the connection to one of the devices must
be established first (see section “Connection” on page 17).
¾
Open the Configuration file management dialogue via Service > Configuration file
> Upload ....
Fig. 13-4
¾
Click Browse….
¾
Select the relevant configuration file on your data storage device.
¾
Activate the Broadcast checkbox.
¾
Enter the First IP address and the Last IP address of the relevant device group.
¾
Enter the Username.
¾
Enter the Password.
¾
Confirm with OK.
At the end of the transfer the list of transferred (or skipped) configuration settings is dis
played.
General information about the device is displayed in the Info dialogue.
¾
Click Info … in the configuration menu.
Fig. 13-5
The following information is displayed:
• Device type
• Software version number of the device
• Version number of the encoder
• Version number of the Linux kernel
• Serial number
• Uptime
13.4
MAC address
The MAC address of the device is displayed in the Network settings dialogue.
Fig. 13-6
The device can be reset to its default factory settings at any time.
¾
Open the Factory settings dialogue via Service > Factory settings ….
The Factory settings dialogue is displayed:
Fig. 13-7
¾
Confirm with OK.
13.6
Activations
The Activations dialogue allows you to activate possible extra features.
For information about available extra features contact the Dallmeier Support.
For purchasing activation codes, contact the Dallmeier electronic Sales Department.
¾
Open the Activations dialogue via Service > Activations ....
Fig. 13-8
¾
Enter the Activation code.
¾
Confirm with OK.
14 Image transmission
The device can be configured as active network component for streaming of audio and
video data (see section “Video streaming” on page 41).
In addition the device, as a passive network component, can be triggered for transmission
of audio and video data via various transport and data protocols by external devices and
applications.
14.1
Web browser
Current video data can be retrieved as a single image (JPEG) by any web browser.
Transmission protocol
HTTP
Transport protocol
TCP
Port
80
Note that
• the used Encoder must be set to MJPEG.
• the used Encoder must be activated.
• the JPEG live access right must be activated.
Use the following retrieve expression for the various encoders:
Encoder 1
http://IP address of the device/live/image0.jpg
Encoder 2
http://IP address of the device/live/image1.jpg
The displayed image can be refreshed anytime. The retrieve expression can be integrated
in a HTML (JavaScript) page that refreshes the image automatically.
14.2
RTSP application
The live video can be retrieved and controlled (start and stop) by external RTSP capable
applications. This function does not affect the “Video Streaming“ function (see section “Vi
deo streaming” on page 41).
Communication protocol RTSP
Transmission protocol
RTP
Transport protocol
UDP
Port
554
• UDP provides data transmission with a relatively low delay.
• packet loss (lack of images) may occur during transmission.
• the used Encoder must be activated.
• the RTSP live access right must be activated.
Use the following retrieve expression for the various encoders:
Encoder 1
rtsp://IP address of the device/encoder1
Encoder 2
rtsp://IP address of the device
Encoder 1 and 2 can be retrieved by two applications simultaneously. This allows realizing
a dual streaming functionality (two streams with different quality).
The required bandwidth rises proportionally when several applications request the data of
one encoder. In this case a multicast configuration should be preferred, because it requires
the bandwidth for one stream only.
If cleaning is required, wipe the housing (outside) with a dry, anti-static cloth.
NOTICE
Damage to the surface of the device!
¾
Do not use detergents.
16 Pin assignment
Fig. 16-1 Housing back side
16.1
Analogue video preview output
Fig. 16-2
1 Video signal
2 Not used
3 Video Ground
16.2
Serial interface
Fig. 16-3
Serial interface (RS485,
2-pole Weidmüller male connector)
Analogue video preview output
(2.5 mm phone jack)
2
1
3
RS485 (A) / TR+
RS485 (B) / TR-
17 Technical data
Following technical data was valid at the time of document compilation.
Refer to www.dallmeier.com for possible updates.
Operating mode
Encoding, streaming
Max. video encoder channels
1× analogue video channel
Supported cameras
Analogue cameras of Dallmeier and of third party
Supported video/audio formats
MPEG-2, MPEG-4, MJPEG / MPEG-1 Layer 2
Frame rate per encoder channel
Up to 25 fps / 30 fps
Resolution per encoder channel
D1, 4CIF, Half D1, 2CIF, CIF, QCIF
Interfaces
Video inputs
1× CVBS/BNC
Audio inputs
1× 3.5 mm phone jack (stereo)
Ethernet
1× RJ45, 10/100 Mbps
Ethernet protocols
IPv4, TCP, UDP, ARP, ICMP, DHCP, NTP, HTTP, RTSP,
IGMP V2, RTP, RTCP
Serial
1× RS485
Integrated functions
Configuration
Via web browser
Motion detection
Integrated
Languages
German, English, French, Italian (others on request)
Further specifications
Internal hard disks
64 MB RAM ring buffer
(pre- and post alarm, network failure compensation)
Video standard
SDTV (PAL/NTSC)
Voltage supply
24 V AC ±10 % (50/60 Hz) oder via PoE (Class 0)
Power consumption
Max. 6 W
Heating power
Max. 20 BTU/h
Operating temperature
-10°C – 45°C, recommended 0°C – 35°C
Humidity
0 – 90 % RH non-condensing
Operating system
Linux
Dimensions (W x H x D)
Approx. 45 x 45 x 108 mm
Weight
Approx. 0.25 kg
Applicability
Stand-alone
Used in
Office, control and server rooms
Approvals/Certifications
CE, DIN EN 50130-4
Declaration of Conformity
This declaration is valid for following product:
Equipment:
Audio and video streamer
Type:
MicroStreamer-PoE
Hereby the equipment is confirmed to comply with the requirements set out in the Council Direc
tive on the Approximation of the Laws of the Member States relating to Electromanetic Compati
bility (2004/108/EC) and the Council Directives relating to Low Voltage (2006/95/EC).
The following company is responsible for this declaration:
Dallmeier electronic GmbH & Co.KG
Cranachweg 1
D 93051 Regensburg
The measurements were carried out in accredited laboratories.
For the evaluation of above mentioned Council Directives for Electromagnetic Compatibility and
for Low Voltage following standards were consulted:
DIN EN 55022: 2003-09 Class B
DIN EN 50130-4: 2003-09
DIN EN 61000-4-2: 2001-12
DIN EN 61000-4-3: 2003-11
DIN EN 61000-4-4: 2002-07
DIN EN 61000-4-5: 2001-12
DIN EN 61000-4-6: 2001-12
Regensburg, 2009-01-07
Dieter Dallmeier
-CEO-