DG AB12-HSMCRAID Manual
Text of the manual
Copyright©2011 Design Gateway Co,.Ltd. All rights reserved.
HSMC SATA RAID board [AB12-HSMCRAID]
Manual [Ver1.0E]
Introduction
Thank you for choosing HSMC SATA RAID board [Part Number: AB12-HSMCRAID] (“RAID board” in this manual.)
The RAID board is compliant with HSMC standard of Altera and provides 8 SATA channels at maximum by high speed
serial interf
Copyright©2011 Design Gateway Co,.Ltd. All rights reserved.
Figure-2: AB12-HSMCRAID solder side
Connection to the FPGA board
Connect the RAID board with HSMC connector on the FPGA board.
For 2.5”-SATA drive connection, user can directly connect SATA drive with CN0 – CN7 SATA connector on the RAID
board.
Use 4-pin ATX Standard power connector for SATA dr
Copyright©2011 Design Gateway Co,.Ltd. All rights reserved.
Pin Assignment
Pin assignment of HSMC on the RAID board is listed following table-1.
HSMC
Pin# (*1)
Samtec
Pin#
(*1)
HSMC
definition
Signal
Name
RAID Bd connection
destination
1
1 TX_P7
HT7P
CN7-S2 (TX Pos)
2
2 RX_P7
HR7P
CN7-S6 (RX Pos)
3
3 TX_N7
HT7N
CN7-S3 (TX Neg)
4
4 RX_N7
HR7N
CN7-S5 (RX Neg
Copyright©2011 Design Gateway Co,.Ltd. All rights reserved.
Disclaimer
DesignGateway is exempted from any damage to the connected SATA device or FPGA board.
DesignGateway does not guarantee transfer speed performance.
[Inquiry]
URL : http://www.design-gateway.com/
Email : mailto:[email protected]
Revision History
Revision
Date
Description
1.0E
13-Jul
Component side GND test pin
Solder side GND test pin
[POWER]
(No mount)
(LVDS-level differential clock)
1-2:Short
2-3:Open
AB12-HSMCRAID
1.0
RAID
A3
1
1
Friday, January 13, 2012
Title
Size
Document Number
Rev
Date:
Sheet
of
PWR5V
HR0N
JTAG
JTAG
HT0N
HT0P
HR0P
HT4N
T2P
T3P
R6P
HR1N
R2N
HT6P
HT7N
T0P
HT5P
HR0N
R1