Festo CPX-FB33 Operating Instructions Manual

Specifications

Brand: Festo
Category: Industrial Electrical
Model: CPX-FB33 (Operating Instructions Manual), prSS255DeGFLs
File Type: PDF
File Size: —
Pages: 30 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (30 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 09/08/2026).

Read Online

Read the Festo CPX-FB33 Operating Instructions Manual online using the built-in PDF viewer.

CPX-FB33 Operating Instructions Manual: Key Pages of Document

Translation of the original instructions

PI PROFIBUS PROFINET® is a registered trademark of its respective trademark holder in certain coun- tries. 2 Festo — CPX-(M)-FB33/34/35/43/44/45 — 2020-04e ...

Festo — CPX-(M)-FB33/34/35/43/44/45 — 2020-04e

1 About this document................................................................................................... 4 1.1 Applicable Documents.................................................................................................. 4 1.2 Product Version............................................................................................................ 4 2 Safety........................................................................................................................... 4 2.1 Safety Instructions........................................................................ ...

About this document

1.1 Applicable Documents All available documents for the product è www.festo.com/sp. Document Contents CPX system description (CPX-SYS-...) Detailed information on the CPX terminal Brief instructions for bus node Essential information on the product Operating instructions for bus node Detailed information on the product Tab. 1 Applicable Documents 1.2 Product Version This document refers to the following hardware version of the specified product: Product Version CPX-FB33 Bus node CPX-FB33 from revision 07 CPX-(M)-FB34 Bus node CPX- (M) -FB34 from revision 07 CPX-(M)-FB35 Bus node CPX- (M) -FB35 from revision 07 CPX-FB43 Bus node ...

Before working on the product, switch off the power supply and secure it against being switched

on again. – This product can generate high frequency malfunctions, which may make it necessary to imple- ment interference suppression measures in residential areas. – Comply with the handling specifications for electrostatically sensitive devices. 2.2 Intended Use The bus node is intended exclusively for operation as a station (IO Device) in the industrial Ethernet system PROFINET IO. The product may only be used in combination with the CPX Terminal in an industrial environment. 2.3 Training of Qualified Personnel This description is intended exclu ...

Fast Start-up can be combined with the Remote I/O operating mode.

Deactivation of the crossover function speeds up the Fast Start-up function. The Fast Start-up function is switched over in the control software at two configuration levels: – Basic hardware configuration in the properties for the CPX terminal – CPX terminal configuration with allocation of the configuration table Identification & Maintenance (I&M) This function serves as an electronic rating plate and offers uniform, manufacturer-independent access to device-specific online information over the internet. PROFIenergy The function supports targeted shut-off of consumers that are not r ...

Consult your local Festo repair service if you have any questions or technical problems.

5.2 Configuration 5.2.1 Product design 1 LED Displays 2 Memory card (only for FB33/34/35) 3 Network connection 4 DIL Switch 5 Service interface 6 Product labelling Fig. 1 Connection and display components 5.2.2 Product variants The following software and hardware revisions are a prerequisite for using the functions: Bus bus node revision number Function Software Hardware Priority start-up (Fast Start-up) From Rev 12 From Rev 11 Identification & Maintenance (I&M) From Rev 14 From Rev 1 PROFIenergy From Rev 20 From Rev 1 Media Redundancy Protocol (MRP) From Rev 20 Fr ...

Bus bus node revision number

Function Software Hardware Media Redundancy for Planned Duplication (MRPD) From Rev 50 From Rev 45 S2 system redundancy From Rev 50 From Rev 45 Isochronous real time (IRT) From Rev 21 From Rev 1 Tab. 3 Required revision numbers for using the functions The revision numbers of the hardware and software for the bus node can be checked with the control software, the Festo Maintenance Tool (FMT) or the Festo Field Device Tool (FFT). 5.2.3 LED displays LED Network status LEDs LED CPX-specific LEDs NF Network Failure (red) PS Power System (green) M/P Maintenance/PROFIenergy (green or yellow) PL Power Load (green) TP1 Link/Traffic ...

1 Memory card

2 DIL switch: operating mode 3 DIL switch: diagnostics mode Fig. 2 Control elements for PROFINET DIL Switch A bus node must be operated as a master in the CPX terminal. The "Remote I/O" operating mode must be set on this bus node. The "Remote Controller " operating mode must be set on all other bus nodes. The 2 DIL switch is used to set the operating mode : DIL switch 2 Description 1: OFF 2: OFF (factory set- ting) Remote I/O operating mode All functions of the CPX terminal are controlled by the PROFINET IO controller. 1: ON 2: OFF Remote Controller operating mode A CPX-CEC-xx takes over the I/O open-loop control. ...

DIL switch 3

Description Remote I/O Remote controller 1: ON 2: ON Reserved Reserved Tab. 6 Setting the diagnostics mode Reserved DIL switches are blocked for future functions and must not be used. The setting of the DIL switches for operating mode and diagnostics mode must match the settings in the open-loop control. Memory card The bus nodes CPX-(M)-FB43/44/45 do not support memory cards. The memory card holds configuration data for the PROFINET addressing: – Fieldbus device name – IP address The configuration data can be conveniently transferred to the new bus node with the memory card when replacing a bus node. The data on the memory card have p ...

Pin allocation of the network interface of the bus node CPX-FB33/43 (M12)

Bushing Pin Signal Explanation 1 TD+ Transmitted data (Transmit Data) + 2 RD+ Received data (Receive Data) + 3 TD– Transmitted data – 4 RD– Received data – M12, D-coded Housing Shield/FE Shield/functional earth Tab. 8 Network interface of the bus node CPX-FB33/43 Pin allocation of the network interface of the CPX-M-FB34/44 bus node (RJ45) Bushing Pin Signal Explanation 1 TD+ Transmitted data (Transmit Data) + 2 TD– Transmitted data – 3 RD+ Received data (Receive Data) + 4 n.c. Not connected 5 n.c. Not connected 6 RD– Received data – 7 n.c ...

Overview of connections and plug

Bus node Connection technology Network connectors CPX-FB33/43 2 x M12, D-coded, female, 4-pin, in accordance with IEC 61076-2 NECU-MS-D12G4-C2-ET CPX-M-FB34/44 2 x RJ45, push-pull, Cu, AIDA, in accordance with IEC 60603, IEC 61076-3 FBD-RJ45-PP-GS CPX-M-FB35/45 2 x SCRJ, push-pull, 650 nm, AIDA, in accordance with IEC 61754-24 FBD-SCRJ-PP-GS Tab. 11 Connection technology and network connectors In the following table, the cable lengths were used in accordance with the specifications for PROFINET networks. Network connectors Cable specification NECU-MS-D12G4-C2-ET Ethernet cable, shielded, Cat 5/5e, 6 … 8 mm, 0 ...

The bus node is mounted in an interlinking block of the CPX terminal.

1 Screws 2 CPX bus node 3 Interlinking block Fig. 3 Mounting the bus node in an interlinking block – Before working on the product, switch off the power supply and secure it against being switched on again. – CPX-M-FB35/45 only permissible on metal linking. Disassembly 1. Unscrew screws. 2. Carefully lift the bus node. Assembly 1. Check seal and sealing surfaces and insert the bus node. 2. Screws must be placed so that the self-tapping threads are used. Tighten the screws by hand cross-wise. Tightening torque: 0.9 … 1.1 Nm. Use suitable screws for the interlinking ...

Information on mounting the CPX terminal can be found in the CPX system description (CPX-SYS-…).

7.2 Connecting to the network Installation guidelines Observe the installation guidelines of the PROFINET user organisation (PNO): è www.profibus.com/download/ NOTICE! Unauthorised Access to the Device Can Cause Damage or Malfunction. • When connecting the device to a network, protect the network from unauthorised access. Standards for security in information technology can be used for network protection meas- ures, e.g. IEC 62443, ISO/IEC 27001. An access password only protects against unintentional modification. For additional information è Gui ...

Network connection (RJ45)

Plug: FBD-RJ45-PP-GS CPX-M-FB35/45: Network connection (SCRJ) Plug: FBD-SCRJ-PP-GS CPX-M-AK-C Service interface Connecting cable: KV-M12-M12-… ISK-M12 Tab. 13 Connection technology and cover caps for degree of protection 7.4 Power Supply Bus nodes are supplied with power via the interlinking blocks. If there are problems with the power supplyè 10 Diagnostics. 8 Commissioning NOTICE! Malfunction due to incorrect switch-on sequence. • First switch on the operating voltage supply of all network stations and then the operating power supply of the open-loop control. CPX- ...

Tab. 14 Behaviour of the display components after error-free commissioning

Information on troubleshooting in the event of incorrect behaviour è 10 Diagnostics. 9 Parameterisation The behaviour of the CPX terminal can be set individually by parameterisation. The following paramet- erisation variants are distinguished: – System parameterisation, e.g. deactivating error messages – Module parameterisation (module-specific and channel-specific), e.g. module monitoring, set- tings for errors, adjustment of debouncing times for inputs – Parameterisation of the diagnos ...

Bus node parameters

Bus node parameters Description/setting options Standard CPX parameters – SCS monitoring – SCO monitoring – Monitoring UOUT – Monitoring UVAL – SCV monitoring – Fail-safe – Force mode – System start with external parameters or default parameters or with saved parameters – Diagnostic memory Standard CPX parameters – for further informa- tion è CPX system description (CPX-SYS-…) Note The parameters of the diagnostic memory can only be set via the CPX-MMI or CPX-FMT. Device-specific parameters Diagnostic message filter Undervoltage UOUT/UVAL – Only available for bus nodes from Rev 14. – Displayed in the ...

Bus node parameters

Description/setting options Analogue process value representation (byte sequence) Special bus node parameter in Intel/Motorola format - defines the representation of process values of the analogue modules - setting options: – Intel byte sequence (LSB-MSB, “Little Endian”; factory setting): process values are displayed in the Intel format (least significant bit left, most significant bit right) – Motorola byte sequence (MSB-LSB, “Big Endian”): process values are displayed in the Motorola format (most significant bit left, least significant bit right) This parameter can also be set via the I/O dia- gnostic interface using ...

The displayed diagnostic information is dependent on the settings on the bus node (è DIL Switch) as

well as on the parameterisation of the CPX terminal or the controller. 10.2 Diagnostics via LED displays Various status LEDs are available for diagnostics at the bus node. They show hardware errors, config- uration errors and bus errors directly on site, which enables fast error detection. 10.2.1 Network status LEDs NE – Network Status/Network Error LED Sequence Status Error handling LED is off No error (if the PS LED is green) – Network connection not OK - possible causes: Check: – Only before initial start-up: Configuration defective, e.g. MAC- ...

M/P – Maintenance/PROFIenergy

LED Sequence Status Error handling LED illumin- ated yellow Maintenance action required Check: – Operating voltage – Plugs – Fibre optic cable LED flashes green PROFIenergy activated – Tab. 17 Network status LED – M/P TP1, TP2 – Connection Status LED Sequence Status Error handling LED is off No physical network connection Check network connection/net- work cable. LED illumin- ated Network connection OK – LED flashes – Both LEDs flashing syn- chronously: module loca- tion, e.g. for troubleshoot- ing or during configuration – Tab. 18 Network status LEDs - TP1 and TP2 Diagnostics 20 Festo — CPX-(M)-FB33 ...

Industrial Electrical PDF Instructions

Cutler-Hammer Digitrip RMS 510
Eaton Cutler-Hammer Digitrip RMS 510
01.07.2026 79 pages

AD 33-855-4 lnstructions lor the Application ol Digitrip RMS 510,610,810, &-' 910 Retrolit Kits on Power Circuit Breakers Cutler-Hammer Eif.il Product operation manual for the Eaton Cutler-Hammer Digitrip RMS 510 Industrial Electrical. It provides detailed operation instructions and technical specifications, connectivity setup, energy usage, component overview.

Mark VI
S&C Mark VI
11.08.2026 28 pages

June 11, 2012© S&C Electric Company Instruction Sheet 712-501 S&C Circuit-Switchers — Mark VI Outdoor Transmission (69 kV through 138 kV) Operation Table of Contents Section Page Section Page Introduction Qualified Persons . . . . . . . . . . . User setup guide for the S&C Mark VI Switch. The documentation includes configuration options, user instructions, service contacts.

OD-BHD-MS75
OEZ OD-BHD-MS75
08.05.2026 4 pages

MOUNTING SET MONTÁŽNÍ SADA OD-BHD-MS75 Montáž, obsluhu a údržbu smí provád t jen osoba s odpovídající elektrotechnickou kvalifikací. Installation, service and maintenance of the electrical equipment may be carried out by an authorized person only. User instructions for the OEZ OD-BHD-MS75 Industrial Electrical. The document offers guidance on troubleshooting, maintenance, setup guidelines, product specifications.

VNG 602-02
SSS Siedle VNG 602-02
31.03.2026 12 pages

Produktinformation Video-Netzgerät Product information Video line rectifier Information produit Redresseur secteur vidéo Opuscolo informativo sul prodotto Alimentatore video Productinformatie Video-netgelijkrichter Produktinformation Video-strømforsyning P Product usage guide for the SSS Siedle VNG 602-02 Industrial Electrical. It offers guidance for setup and reset instructions, regulatory notices, maintenance, connectivity options.