Felder A3-31 Adjustment Manual
Text of the manual
There are four panels that can be removed from the top side: two
covering the hinges, and two covering the kip levers.
To access the adjustment bolts on the hinges, remove the back panel
comprising of nine screws. (Two screws are not shown as they are locat-
ed on the opposing side)
Loosen bolt (indicated above) to adjust the outfeed table up
and down. Adjust table, using wrench, until bolt is set within
the middle of its guide.
Use the four set screws on the hinge-pin to make fine adjust-
ments and to make the infeed and outfeed tables parallel to the
cutterblock.
Adjust the castle nuts in relation to the hinge adjustments
so that the cast-iron tables are even across the cutter
block.
Place the straightedge on the cutter block assembly and con-
firm that the tables are coplanar with the cutter block assem-
bly.
Measure the cast-iron to the cutterblock on the hinge-side first and
the front side second.
NOTE: After each adjustment, open and close the tables, and re-
check measurements.
Once the outfeed table is level and parallel to the cutter block,
use a straightedge to level the infeed table.