Text of Extech Instruments CO80 Manual 

Extech Instruments CO80 CO80 V3.1 04/06

2 Table of Contents 1. Introduction 4 2. Instrument Overview 5 2.1. Standard Items 5 2.2 Options 5 2.2.1. Leak Detection Capability 5 2.2.2. Air/Liquid/Surface Probe 5 2.3 Front View 6 2.4 Back View 7 2.5 Keypad 8 2.6 Display 9 2.7. Inlet Ports 10 2.8 Filter/Water Trap 11 2.9 Thermocouple Socket (Type-K) 12 2.10 Infrared Window 13 3. Setting Up 13 3.1 Power 13 3.2 Probe Selection 14 4. Taking Combustion Readings 15 4.1 Summary Proced
CO80 V3.1 04/06 3 5. Other Functions 24 5.1 Taking Pressure Readings 24 5.1.1. Standard Pressure Readings 25 5.1.2. Tightness Test 26 5.1.3. Pressure and Temperature Readings 29 5.2 Taking Efficiency Readings 30 5.3 Clock 31 5.4 Header Settings 31 5.4.1. Changing the Header Characters 31 5.4.2. Setting your Security Code 32 5.4.3. Changing a Security Coded Header 33 5.5 Taking Carbon Monoxide Readings 33 5.5.1 CO Spot Leak Detection 33 5.5.2 CO Room
CO80 V3.1 04/06 4 1. Introduction Thank you for your purchase of the Extech CO80. This instrument has been specifically developed to provide the many functions required by the modern boiler service engineer and to assist with compliance to existing and future legislation. The CO80 now offers five tools in one instrument: 1. Flue Gas Combustion Analyser. 2. Differential Manometer. 3. Differential Thermometer. 4. Real time Carbon Monoxide Gas Leak De
CO80 V3.1 04/06 5 2. Instrument Overview 2.1. Standard Items Your CO80 kit comes supplied with the following items as standard: a) CO80 flue gas analyser b) Sample/thermocouple probe, with 2.5 meters of tubing and cable c) Filter/water trap d) Battery charger e) 2 off silicon tubing for pressure reading f) Soft carrying case 2.2 Options 2.2.1. Leak Detection Capability This sensor option is fitted inside the instrument, enabling the CO80 to detect f
CO80 V3.1 04/06 6 2.3 Front View Charger Socket Exhaust Cover Infrared Window Gas & Pressure Inlet Ports Thermocouple Sockets Keypad LCD Display
CO80 V3.1 04/06 7 2.4 Back View Exhaust Cover Infrared Window Gas & Pressure Inlet Ports Thermocouple Sockets Barcode Label Calibration Label
CO80 V3.1 04/06 8 2.5 Keypad Turns the instrument ON or OFF. Note that the instrument will automatically switch off if not used for a period of 15 minutes (see 4.2 for additional information) The straightforward membrane keypad comprises 6 keys, where a single touch will have the following functions: Used to reset the pressure to ambient levels. Activates the Tightness Test Turns the back light on/off and records the pressure for the soundness test
CO80 V3.1 04/06 9 2.6 Display There are eight standard displays on the CO80, although several of the displays have multiple functions and options. These depend upon the probes connected and menu selected. Display 1 CO in ppm, carbon dioxide in %, and ratio of the 2 gases – use this screen to provide an instant “health check” of the boiler. Display 4 Displays the positive and negative pressure (selected by connecting to the appropriate inlet).
CO80 V3.1 04/06 10 2.6 Display (continued) Display 6 Time (24 hours), day, month and year. Display 8 Provides temperature information. The outlet (flue) temperature is displayed on the top of the screen and the inlet at the bottom, with the difference between the two displayed in the middle. Display 7 Provides information on the CO levels for the room test. Pressing & holding the “Log” starts the test and the display alternates between the elaps