Extech Instruments CO80 Manual
| Brand: | Extech Instruments |
| Category: | Measuring Instruments |
| Model: | CO80 (Manual ) |
| File Type: | |
| File Size: | — |
| Pages: | 48 |
Text of Extech Instruments CO80 Manual
Extech Instruments CO80 CO80 V3.1 04/06
2
Table of Contents
1.
Introduction
4
2.
Instrument Overview
5
2.1.
Standard Items
5
2.2
Options
5
2.2.1.
Leak Detection Capability
5
2.2.2.
Air/Liquid/Surface Probe
5
2.3
Front View
6
2.4
Back View
7
2.5
Keypad
8
2.6
Display
9
2.7.
Inlet Ports
10
2.8
Filter/Water Trap
11
2.9
Thermocouple Socket (Type-K)
12
2.10
Infrared Window
13
3.
Setting Up
13
3.1
Power
13
3.2
Probe Selection
14
4.
Taking Combustion Readings
15
4.1
Summary Proced
CO80 V3.1 04/06 3
5.
Other Functions
24
5.1
Taking Pressure Readings
24
5.1.1.
Standard Pressure Readings
25
5.1.2.
Tightness Test
26
5.1.3.
Pressure and Temperature Readings
29
5.2
Taking Efficiency Readings
30
5.3
Clock
31
5.4
Header Settings
31
5.4.1.
Changing the Header Characters
31
5.4.2.
Setting your Security Code
32
5.4.3.
Changing a Security Coded Header
33
5.5
Taking Carbon Monoxide Readings
33
5.5.1
CO Spot Leak Detection
33
5.5.2
CO Room
CO80 V3.1 04/06 4
1.
Introduction
Thank you for your purchase of the Extech CO80. This instrument has
been specifically developed to provide the many functions required by the
modern boiler service engineer and to assist with compliance to existing
and future legislation.
The CO80 now offers five tools in one instrument:
1. Flue Gas Combustion Analyser.
2. Differential Manometer.
3. Differential Thermometer.
4. Real time Carbon Monoxide Gas Leak De
CO80 V3.1 04/06 5
2.
Instrument Overview
2.1.
Standard Items
Your CO80 kit comes supplied with the following items as standard:
a)
CO80 flue gas analyser
b)
Sample/thermocouple probe, with 2.5 meters of tubing and cable
c)
Filter/water trap
d)
Battery charger
e)
2 off silicon tubing for pressure reading
f)
Soft carrying case
2.2
Options
2.2.1.
Leak Detection Capability
This sensor option is fitted inside the instrument, enabling the CO80 to
detect f
CO80 V3.1 04/06 6
2.3
Front View
Charger Socket
Exhaust Cover
Infrared Window
Gas & Pressure
Inlet Ports
Thermocouple
Sockets
Keypad
LCD Display
CO80 V3.1 04/06 7
2.4
Back View
Exhaust
Cover
Infrared
Window
Gas & Pressure
Inlet Ports
Thermocouple
Sockets
Barcode
Label
Calibration
Label
CO80 V3.1 04/06 8
2.5
Keypad
Turns the instrument ON or OFF. Note that
the instrument will automatically switch off if
not used for a period of 15 minutes (see 4.2
for additional information)
The straightforward
membrane keypad
comprises 6 keys,
where a single touch
will have the following
functions:
Used to reset the pressure to ambient levels.
Activates the Tightness Test
Turns the back light on/off and records the
pressure for the soundness test
CO80 V3.1 04/06 9
2.6
Display
There are eight standard displays on the CO80, although several of the
displays have multiple functions and options. These depend upon the
probes connected and menu selected.
Display 1
CO in ppm, carbon dioxide in
%, and ratio of the 2 gases –
use this screen to provide an
instant “health check” of the
boiler.
Display 4
Displays the positive and negative
pressure (selected by connecting to
the appropriate inlet).
CO80 V3.1 04/06 10
2.6
Display (continued)
Display 6
Time (24 hours), day, month
and year.
Display 8
Provides temperature
information. The outlet (flue)
temperature is displayed on the
top of the screen and the inlet at
the bottom, with the difference
between the two displayed in
the middle.
Display 7
Provides information on the CO
levels for the room test.
Pressing & holding the “Log”
starts the test and the display
alternates between the elaps