FMS EMGZ308 Operating Manual
Text of FMS EMGZ308 Operating Manual
Operating Manual EMGZ308
Analog Tension Measuring Amplifier
Version 2.03 04/08 st
This operation manual is also available in German.
Please contact your local representative.
Diese Bedienungsanleitung ist auch in Deutsch erhältlich.
Bitte kontaktieren Sie die Vertretung im zuständigen Land.
© by FMS Force Measuring Systems AG, CH-8154 Oberglatt – All rights reserved.
Operating manual EMGZ308
2
1 Safety Instructions
1.1 Description conditions
a) High danger of health injury or loss of life
Danger
This symbol refers to high risk for persons to get health injury or loss life. It has to be
followed strictly.
b) Risk of damage of machines
Caution
This symbol refers to informations, that, if ignored, could cause heavy mecanical damage.
This warning has to be followed absolutely.
c) Notice for proper function
Notice
This symb
Operating manual EMGZ308 3
Table of contents
1
Safety Instructions .................................................................................... 2
1.1
Description conditions
2
1.2
List of safety instructions
2
2
Definitions .................................................................................................. 4
3
System components................................................................................... 4
4
System description ..
Operating manual EMGZ308 4
2 Definitions
Offset:
Correction value for compensation of the zero point difference. Thanks to the offset, it is
ensured that a force of 0N will generate a signal of 0V exactly.
Gain:
Amplification factor for the measuring signal. Use of proper value will set the measuring
range of the sensor exactly corresponding to the signal output range (0...10V).
Strain gauge:
Electronic component that will change its resistance while its l
Operating manual EMGZ308 5
4 System description
fig. 1: Basic structure of the EMGZ308 Tension Measuring Amplifier (picture shows
single channel version)
E308001e
4.1 Functional description
The force sensors measure the tension force in the processed material and transmit the
measuring value as a mV signal to the hybrid module in the measuring amplifier
EMGZ308. The measuring amplifier amplifies the mV signal depending on configuration.
The resulting feedb
Operating manual EMGZ308 6
Fixed setting of gain and offset
Fixed setting is used when maximum thermal stability and vibration-proof conditions are
needed. The signal is pre-amplified with a fixed value and has to be evaluated digitally
(for ex. by a PLC), so that offset and gain can be calculated.
4.4 Block diagram
fig. 2: The block diagram shows the single channel version.
E308002e
Operating manual EMGZ308 7
5 Dimensions
8 x M16 x 1.5
EMGZ308 SERIES
CHANNEL 1
CHANNEL 2
fig. 3
E308013e
Operating manual EMGZ308 8
6 Installation and wiring
Caution
Proper function of the Tension Measuring Amplifier is only guaranteed with the
recommended application of the components. In case of other arrangement, heavy
malfunction can be the result. Therefore, the installation instructions on the following
pages must be followed strictly.
Caution
Local installation regulations are to preserve safety of electric equipment. They are not
taken into considerat
Operating manual EMGZ308 9
6.2 Mounting the force sensors
Mounting of the force sensors is done referring to the FMS Installation manual which is
delivered together with the force sensors.
Wiring to the terminals of the electronic unit is done according to wiring diagram (fig. 5).
Notice
Connecting the shield of the signal cable to the electronic unit and to the force sensor
may cause ground circuits which may interfere the measuring signal massively.
Malf
Operating manual EMGZ308 10
7 Setting into operation
7.1 View of the setting elements
fig. 6: Setting elements
E308008e
7.2 Configuring gain and offset
Gain and offset are configured by jumpers. The settings can be made individually for
each channel.
Gain and offset with infinite setting
If gain and offset are adjusted with the
trimmers, the jumpers have to be set
according to fig. 7. Gain and offset then
may be adjusted using the trimmers (refer
to
„7.5
Operating manual EMGZ308 11
Gain and offset with fixed setting
If the signal is processed by a control unit
(i.e. a PLC), configuration with fixed gain
and offset is recommended (offset = 0;
gain = 1111). Therefore, the jumpers have
to be set according to fig. 8. With this
configuration,
the
good
thermal
characteristics of the hybrid module are
best utilized. The output signal will be
20mA when the nominal force of the
sensor is applied.
7.3 Configuring th
Operating manual EMGZ308 12
7.4 Configuring the lowpass filter
The measuring amplifier provides 2 lowpass filters per channel. They are used to
eliminate faulty signal variations which may be caused by unbalanced rollers, vibrations
of the machine, or equivalent.
Lowpass U
acts only to the tension output
Lowpass I
acts only to the current output
The lower the cut-off frequency, the more sluggish the signal will be. The configuration
is made by soldering a
Operating manual EMGZ308 13
7.5 Calibrating the measuring amplifier
Proceed the calibration for each channel as follows:
• Connect gauge to the tension or current output.
• Connect the first force sensor.
• Check if a positive output signal is appearing when loading the sensor in measuring
direction. If not, exchange the two signal wires of the referring force sensor in the
terminal block (+Signal and –Signal).
• If used, connect the second force
Operating manual EMGZ308 14
8 Trouble shooting
Error
Cause
Corrective action
Output shows signal > 0
although material has no
tension
Offset setting is bad
Re-adjust offset (refer to „7.5 Calibrating the
measuring amplifier“)
Current output is configured
for 4...20mA
Change jumper setting if required
Output signal is not
stable although material
tension doesn’t change
Cut-off frequency too high
Adjust cut-off frequency (refer to
„7.4 Configuring th
Operating manual EMGZ308 15
9 Technical Data
Sensor excitation
5VDC ±20ppm/K max. 30mA [±11ppm/°F]
Gain factor range
fixed: 1111; variable: 500...5000
Offset range
fixed: 0mV; variable: ±9mV
Temperature drift offset
fixed: < 20ppm/K [11ppm/°F]; variable: ca. 50ppm/K [28ppm/°F]
Linearity error
< 0.1%
Tension output
±10V min. 1kΩ
Current output
0/4...20mA max. 500Ω
Lowpass cut-off frequency
adjustable, ca. 1...1000Hz
Power supply
24VDC or 100...24
Operating manual EMGZ308 16
FMS Force Measuring Systems AG
Aspstrasse 6
8154 Oberglatt (Switzerland)
Tel. 0041 44 852 80 80
Fax 0041 44 850 60 06
[email protected]
www.fms-technology.com
FMS USA, Inc.
925 East Rand Road Suite 207
Arlington Heights, IL 60004 (USA)
Tel. 847 392 7872
Fax 847 392 7873
[email protected]
FMS (UK)
Highfield, Atch Lench Road
Church Lench
Evesham WR11 4UG (Great Britain)
Tel. 01386 871023
Fax 01386 871021
fmsuk@fms-te