Guardmaster PROSAFE RPSE Series Installation Instructions

Text of Guardmaster PROSAFE RPSE Series Installation Instructions

(b) Installation Instructions

Notice d'installation Deutch / Français (a) Description The Prosafe rotary key switch is a trapped key unit that isolates power when the coded trapped key is removed. The key can only be romoved by rotating 90° anti-clockwise which in turn changes the state of the switch contacts. Re- insertion of the correct key and rotation 90° clockwise reverts the contacts to the original state, and trapping the key in

(a) WIRING / VERDRAHTUNG / CÂBLAGE

All types excluding RPS 11 4 N/O shown with key free (b) RPS11 type 2 N/O + 2 N/C shown with key free (c) 5 (a) OPERATION / BEDIENUNG / UTILISATION Check for correct operation. Ensure power is isolated when the key is free. Upon correct installation, fixing screws should be coated with a tamper evident varnish or similar compound. Key 'C' Rotated and Free, Power Off. Key 'C' Trapped, Power On. Adjust Position of Flip C

Deutsch / Français

Technical Specifications Conforming to standard EN 292, EN 1088, IEC 947-5-1, GS-ET -19 Contacts all types except RPS11 4 N/O type RPS11 2 N/O + 2 N/C Rating IP20 Finger protection DIN 57106/VDE 0106 T.100 Ambient temp. -10°C to +40°C Mechanical operations 1 x 105 Max. shear force to key 15.1kN Max. torque to key 14Nm Relative operating humidity 25% to 95% Weight 0.85kg Code barrels Tested to 1,000,000 operations Isolator approv

Drg No: 7200029 / Issue No: 1

REPARATUR (t) REPAIR RÉPARATION If there is any malfunction or damage to the unit or key, replace where necessary. No attempt to repair should be made. The unit or key should be replaced before the system is reinstated. This is to declare that the RPSE units conform with the Essential Health & Safety Requirements (EHSR's) of the European Machinery Directive (98/37/EC) and the relevant requirements of the Low Voltage Direc

Guardmaster Switch Owners Instructions: