3040-DB Deadbolt Lock & 4100 Swingbolt Lock

Manager prograMMing STANDARD FEATURES WRONG TRY PENALTY •� Four�(4)�consecutive�invalid�combinations�initiates�five�(5)�minute�delay�period. LOW BATTERY WARNING •� Repeated�LED�flashing�and�beeping�during�opening�indicates�battery � is�low�and�needs�immediate�replacement. AUDIO AND VISUAL SIGNAL •� Double�signal�-�two�(2)�LED�flashes�and�two�(2)�unit�beeps�-�indicates � entry�is�valid�or�accepted.�� •� Triple�signal�-�three�(3)�LED�flashes�and�three�(3)�beeps�-�indicates � invalid�or�not�accepted. PROGRAMMABLE MODES ACTIVE (3045 Handheld Programmer Required) MANAGER COMBINATION�(Factory�set�to�1-2-3-4-5-6)�...............£ •� Add/Remove�User •� Enable/Disable�User USER COMBINATION�.....................................................................£ •� Open�Lock •� Change�Combination TIME DELAY OVERRIDE MODE�....................................................£ •� Ability�to�add�second�combination�to�override�delay�period DUAL COMBINATION MODE�.........................................................£ •� Add�User •� Both�combinations�required�to�open PROGRAMMABLE FEATURES (3045 Handheld Programmer Required) TIME DELAY�....................................................................................£ •� Delay�period�1�-�99�minutes •� Open�period�1�-�19�minutes SILENT SIGNAL ALARM�(Optional�Alarm�Box�Required)�...............£ •� Duress�signal�if�last�number�of�combination�is�entered�using�one � number�higher�or�one�number�lower. DISABLE LOCK�(Optional�Alarm�Box�Required)�.............................£ •� Input�signal�disables�opening�of�lock�by�valid�combination. OPENING THE LOCK 1.�Enter�valid�six�(6)�digit�combination. 2.�The�lock�will�indicate�a�valid�combination�with�a�double�signal. 3.�Within�four�(4)�seconds,�turn�the�keypad�to�the�open�position � (clock-wise)�if�using�a�dead�bolt�style�lock,�or�turn�the�handle�to�the � open�position�if�using�a�swing�bolt�style�lock. 4.�Pull�door�open. •� Invalid�Combination�-�Lock�will�signal�three�(3)�times. CHANGING YOUR COMBINATION ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN (If your unit is programmed for Dual Mode, each combination must be changed independently. Follow these instructions for each combination change.) 1.�Enter�“zero”�six�times. 2.�Enter�your�existing�six�(6)�digit�combination�one�time. 3.�Enter�your�NEW�six�(6)�digit�combination�two�times. 4.�If�a�mistake�is�made�wait�thirty�(30)�seconds�and�repeat�steps�1�-�3. 5.�Test�lock�operation�several�times�before�closing�the�door. CAUTION: When selecting a combination do not use birthday or other predictable data that could give correlation between the user and the combination. Keep the combination secret. •� Valid�Combination�-�Double�signal�after�valid�six�(6)�digit � combination�is�entered. •�Invalid�Combination�-�Triple�signal�indicates�the�old�combination�is � still�valid. ADD USER�(ONLY available if either Manager Mode, Time Delay Override Mode or Dual Mode was activated using the 3045 Hand Held Programmer. Add User is not available if Remote Override feature is activated using the 3045 Hand Held Programmer.) ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN 1.�Enter�the�Manager�combination�and�hold down last digit of the combination until the lock signals with two sets of double beeps. 2.�PRESS 1.�Lock�signals�as�follows: � � One�beep�–�User�is�already�installed�(end�of�operation) � � Two�beeps�–�User�enabled,�go�to�Step�3� � � Three�beeps�–�Not�available;�Function�was�not�programmed�with � � Hand�Held�Programmer�(end�of�operation)� 3.�Enter�NEW�user�combination�twice.�The�lock�signals�twice�after � each�valid�entry. 4.�If�a�mistake�is�made�wait�thirty�(30)�seconds�and�repeat�steps�1�-�3. ©�copyright�2006�� (P/N)12-203�v5�•�6/08� Kaba Mas LLC page�1�of�2 4200�Swingbolt�Lock 3740-2�Deadbolt�Lock SUggESTED�KEyPADS: 3035�Entry 3750�Entry 3190�PrivatII�(Optional)

DISABLE USER�(Manager only.)

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN 1.�Enter�the�Manager�combination�and�hold down last digit of the combination until the lock signals with two sets of double beeps. 2.�PRESS 2.�Lock�signals�once. 3.�User�is�temporarily�disabled.�(User�combination�is�saved�and�will�be�valid�if�reinstated) 4.�If�a�mistake�is�made�wait�thirty�(30)�seconds�and�repeat�steps�1 - 3. REINSTATE USER�(Manager only.) ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN 1.�Enter�the�Manager�combination�and�hold down last digit of the combination until the lock signals with two sets of double beeps. 2.�PRESS 1.�Lock�signals�once. 3.�User�is�reinstated.� 4.�If�a�mistake�is�made�wait�thirty�(30)�seconds�and�repeat�steps�1 - 3. REMOVE USER(Manager only.) ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN 1.�Enter�the�Manager�combination�and�hold down last digit of the combination until the lock signals with two sets of double beeps. 2.�PRESS 3.�Lock�signals�once. 3.�User�and�combination�are�removed�from�the�lock.��(Add�User�feature�is�still�available.) 4.�If�a�mistake�is�made�wait�thirty�(30)�seconds�and�repeat�steps�1 - 3. DUAL MODE OPERATION (If mode is active. Must be programmed using 3045 Hand-Held Programmer) 1.�Must�add�User�to�open�lock.�(See�ADD USER) � •� User�cannot�be�disabled�or�removed. 2.�If�Time�Delay�is�active,�one�valid�combination�will�start�Delay�period. � •� Both�combinations�required�to�open�lock�in�Open�period. TIME DELAY OVERRIDE�(If�mode�is�active.�Must�be�programmed�using�3045�Hand-Held�Programmer) 1.�Must�add�User�to�use�this�mode.�(See�ADD USER) � •� User�cannot�be�disabled�or�removed. 2.�Entering�Override�User�combination�during�Delay�period�will�open�the�lock. PROGRAMMABLE LOCK FEATURES�(Time delay and silent alarm features may be combined with any programmable lock mode.) TIME DELAY�(If feature is active. Must be programmed using 3045 Hand-Held Programmer.) 1.�Entering�a�valid�combination�begins�the�Delay�period. � •� LED�flashes�at�one�(1)�second�intervals. � � -�If�a�valid�combination�is�entered�during�the�Delay,�then�Delay�period�restarts. � � -�If�an�invalid�combination�is�entered�during�Delay,�then�the�Delay�period�aborts. 2.�At�end�of�Delay�period,�the�Open�period�begins. � •� LED�flashes�at�1/2�second�intervals�and�the�entry�beeps�at�ten�(10)�second�intervals. � � -�If�a�valid�combination(s)�is�entered�during�the�Open�period,�then�the�lock�will�open. � � -�If�an�invalid�combination�is�entered�during�Open�period,�then�the�Open�period�continues. � •� Four�(4)�consecutive�invalid�combinations�entered�will�start�the�Wrong�Try�Penalty. SILENT SIGNAL ALARM�(If feature is active AND optional Alarm Box [2789 or 4002] is connected to an alarm system.) 1.�To�send�an�alarm�signal�enter�last�digit�of�combination�one�number�higher�or�one�number�lower. � � •�Example:�Combination:�1-2-3-4-5-6 � � •�Duress:�1-2-3-4-5-5�or�1-2-3-4-5-7 2.�The�lock�will�open�without�any�indication�that�the�duress�signal�has�been�sent. DISABLE LOCK�(If feature is active the alarm box [2789 or 4002] is required. ONLY the Manager is available) Input�signal�to�the�alarm�box�will�disable�opening�of�the�lock�by�a�valid�combination. WRONG TRY PENALTY � •� Entry�of�four�(4)�consecutive�invalid�combinations�starts�a�five�(5)�minute�delay�period. � � -�LED�flashes�at�ten�(10)�second�intervals. � •� At�the�end�of�the�delay�period,�two�more�consecutive�invalid�combinations�will�restart�the�five�(5)�minute�delay�period. � � Entry will not respond to keystrokes during delay period. BATTERY LOW WARNING Repeated�LED�flashing�and�beeping�during�an�opening�indicates�that�the�battery�is�low�and�needs�immediate�replacement. � •� Uses�alkaline�battery�only.�(Example:�Duracell™�or�Eveready™�alkaline�batteries.)�It�is�recommended�that�batteries�are�replaced�at�least � � once�a�year. � •� For�battery�replacement�instructions,�see�the�input�unit’s�“User�Operating”�guide. � � Lock contains a nonvolatile memory; even with batteries removed the lock will retain all programming. Mounting instructions are available at www.kaba-mas.com. ©�copyright�2006�� (P/N)12-203�v5�•�6/08� Kaba Mas LLC page�2�of�2

Other Locks Manuals