International Safety Symbols

This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation SAFETY NOTES • Do not exceed the maximum allowable input range of any function • Do not apply voltage to meter when resistance function is selected. • Set the function swi

• If the equipment is used in a manner not specified by the manufacturer, the protection provided

by the equipment may be impaired. Input Limits Function Maximum Input A AC 400A V DC, V AC 600V DC/AC Resistance, Diode, Continuity , 250V DC/AC Meter Description 1. Current clamp 2. Non-contact AC voltage indicator light 3. Clamp trigger 4. Rotary Function swith 5. Data Hold button 6. Back light button 7. LCD display 8. MODE select button 9. Range button

Axio MET AX-202 Range & Resolution

Accuracy (% of reading) AC Current (50/60Hz) 2.000AAC ± (2.5 % + 10 digits) 20.00AAC ± (2.5 % + 4 digits) 200.0AAC ± (2.5 % + 4 digits) 400.0 AAC ± (3 % + 4 digits) DC Voltage 200.0 mVDC ± (0.8% + 2 digits) 2.000 VDC ± (1.5% + 2digits) 20.00 VDC 200.0 VDC 600.0 VDC ± (2 % + 2 digits) AC Voltage 200.0 mVAC ± (1.5% + 35 digits) 2.000 VAC ± (1.8% + 8 digits) 20.00 VAC 200.0 VAC 600.0 VAC ± (2.5% + 8 digit

2000 counts LCD

AC Current 50-60Hz (AAC) AC Voltage bandwidth 50-60Hz (VAC) Operating Temperature 41 to 104oF (5 to 40oC) Storage Temperature -4 to 140oF (-20 to 60oC) Operating Humidity Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F(40°C) Storage Humidity <80% Operating Altitude 7000ft. (2000meters) maximum. Over voltage Category III 600V Battery One 9V Battery Auto OFF approx. 15 minutes Dimensions/Weight 197x70x40mm/183g Sa

1. Set the Function switch to the 400.0A ~ 2.000A range.

2. If the range of the measured is not known, select the higher range first then move to the lower range if necessary. 3. Press the trigger to open jaw. Fully enclose one conductor to be measured. The clamp meter LCD will display the reading. DC/AC Voltage Measurements 1. Insert the black test lead into the negative COM terminal and the red test lead into the positive V terminal. 2. Set the functio

Axio MET AX-202 Non-Contact AC Voltage Measurements

1. Touch the probe tip to the hot conductor or insert into the hot side of the electrical outlet. 2. If AC voltage is present, the detector light will illuminate. NOTE: The conductors in electrical cord sets are often twisted. For best results, rub the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor. NOTE: The detector is designed with high sensitivity. Static ele