Hioki 9335 Instruction Manual
Text of the manual
Notes on Use
i
Chapter 1 Overview
1
1.1 Product Overview
1
1.2 Specifications
2
Chapter 2 Setup
7
2.1 Minimum System Configuration
7
2.2 Installation and Uninstallation
8
2.3 Starting and Quitting the Wave Processor
8
Chapter 3 Waveform Window
9
3.1 Loading Waveform Files
9
3.2 Working in the Waveform Window
10
3.2.1 Waveform Window Menu
11
3.2.2 Main Toolbar
12
3.2.3 Waveform Window Toolbar
13
3.2.4 Popup Menu
14
3.2.5 Setting Waveform Graphs
17
3.2.6 Setting Display Ranges
18
3.3 Time-Axis Cursors
19
3.3.1 Manipulating Cursors
19
3.3.2 Displaying the Time-Axis Cursor Dialog Box
20
3.4 Voltage Cursors
21
3.4.1 Manipulating Cursors
21
3.4.2 Displaying the Voltage Cursor Dialog Box
21
3.5 Interval-specifying Cursors
22
3.5.1 Manipulating Cursors
22
3.5.2 Displaying the Interval-specifying Cursor
Dialog Box
22
3.6 Waveform Information Dialog Box
23
3.7 Searching Waveform Data
23
3.7.1 Search by Date/time
23
3.7.2 Search by Maximum, Minimum, Maximal,
or Minimal Value
24
3.7.3 Search by Level
25
9335A981-12
3.8 Numerical Operation
26
3.8.1 Setting Calculations
27
3.8.2 Executing Calculations
30
3.9 Manipulating the Waveform on Each Channel
31
3.9.1 Waveform Operations
31
3.9.2 Setting Others
32
3.10 Setting Scaling and Channel Comments
33
3.10.1 Setting Scaling
33
3.10.2 Setting Channel Comments
34
3.11 Using Tools
34
3.11.1 Registering Applications
34
3.11.2 Executing the Tool
34
3.12 Saving Waveform Data over Existing Data
35
3.13 Numeric Display of Waveform Data
35
3.13.1 Logging Window Menus
36
3.13.2 Logging Window Toolbar
37
3.13.3 Other Operations
37
3.14 Waveform Window Hard Copy
38
3.14.1 Setting Hard Copy
38
3.14.2 Executing Hard Copy
38
Chapter 4 Text Conversion
39
4.1 Converting All
39
4.2 Converting Partially
40
4.3 Converting Collectively
40
Chapter 5 X-Y Synthesis Window
41
5.1 Displaying the X-Y Synthesis Window
41
5.2 Manipulating the X-Y Synthesis Window
42
5.2.1 X-Y Window Menus
42
5.2.2 X-Y Waveform Toolbar
43
5.2.3 Popup Menu
43
5.2.4 Setting XY Graphs
45
5.2.5 Setting the XY Synthesis Range
46
5.3 Cursor Function
47
5.3.1 Trace Cursors
47
5.3.2 Voltage Cursors
48
5.3.3 Popup Menu
49
5.4 Waveform Information Dialog Box
49
5.5 Manipulating XY Graphs
49
5.5.1 Waveform Operations
49
5.5.2 XY Window Hard Copy
50
5.5.3 Setting Scaling and Channel Comments
50
Chapter 6 Printing
51
6.1 Screen Print
51
6.1.1 Printing
51
6.1.2 Print Preview
51
6.1.3 Setting Screen Print
51
6.2 Detail Print
52
6.2.1 Printing
52
6.2.2 Detail Print Preview
52
6.2.3 Setting Detail Print
52
6.3 Logging Printing
56
6.3.1 Logging Printing
56
6.3.2 Logging print preview
56
6.3.3 Logging print settings
56
_____________________________________________________________________________________________
______________________________________________________________________________________________
_____________________________________________________________________________________________
______________________________________________________________________________________________
Notes on Use
______________________________________________________________________________________________
NOTE
Denotes items of advice related to performance of the
equipment or to its correct operation.
Introduction
Notes on Use
Thank you for purchasing this HIOKI "9335 WAVE PROCESSOR". To get
the maximum performance from the unit, please read this manual first, and
keep this at hand.
Trademarks
Microsoft and Windows, Windows Vista, Microsoft Excel are either
registered trademarks or trademarks of Microsoft Corporation in the United
States and other countries.
In order to ensure safe operation and to obtain maximum performance from
the unit, observe the cautions listed below.
Always hold the disc by the edges, so as not to make fingerprints on the
label side or scratch the printing.
Never touch the recorded side of the disc. Do not place the disc directly
on anything hard.
Do not wet the disc with volatile alcohol or water, as there is a possibility
of the label printing disappearing.
To write on the disc label surface, use a spirit-based felt pen. Do not use a
ball-point pen or hard-tipped pen, because there is a danger of scratching
the surface and corrupting the data. Do not use adhesive labels.
Do not expose the disc directly to the sun's rays, or keep it in conditions
of high temperature or humidity, as there is a danger of warping, with
consequent loss of data.
To remove dirt, dust, or fingerprints from the disc, wipe with a dry cloth,
or use a CD cleaner. Always wipe radially from the inside to the outside,
and do no wipe with circular movements. Never use abrasives or solvent
cleaners.
In the interests of ongoing product developments, there may be minor
discrepancies between screen displays and the operating instructions, and
in the data conversion process.
HIOKI cannot accept any responsibility for the results of using this
product.
The following symbols are used in this Instruction Manual to indicate the
relative importance of cautions and warnings.
Notes on Use
______________________________________________________________________________________________
1.1 Product Overview
______________________________________________________________________________________________
Chapter 1
Overview
1.1 Product Overview
The 9335 WAVE PROCESSOR offers the following features:
1. Waveform display
The waveform files recorded by the HIOKI MEMORY HiCORDER can
be displayed on a PC monitor. The displayed waveform data can be
magnified or compressed and scrolled. Even large-capacity waveform files
can be loaded and displayed at high speed.
2. Print
The waveforms recorded by the HIOKI MEMORY HiCORDER can be
printed in detail, along with hard copies of the waveform window
produced from a printer.
3. Search function
The date/time, voltage levels, maximum and minimum values, and any
other necessary data can be searched.
4. Numerical operation
Average value, maximum value, standard deviation, and various other
data can be obtained by calculation.
5. Text convert function
The waveform files recorded by the HIOKI MEMORY HiCORDER can
be converted into text format for processing by such spreadsheet software
as Microsoft Excel .
6. X-Y synthesis
The waveform data can be X-Y synthesized before being displayed on the
screen.
PCs running Windows.
1 GHz or faster 32-bit or 64-bit processor, and 2 GB RAM
Video capabilities with 1024 x 768 resolution or higher and 256 or more colors
Minimum hard disk space required for installation 20 MB or more
CD-ROM drive required (used for installation)
OS
Windows 7 (32bit/64bit), Windows 8 (32bit/64bit), Windows 10
(32bit/64bit)
Supported recorders
HIOKI 8807-01, 8808-01, 8807-51, 8808-51,
8714-01, 8715-01, 8730-10, 8731-10
HIOKI 8870-20, 8870-21, MR8870-20, MR8870-30,
MR8880-20, MR8880-21
HIOKI 8826, 8835, 8835-01, 8841, 8842, 8720,
8860, 8861, 8860-50, 8861-50 (Can not load the waveform
data with different sampling rates)
Compatible input units:
8936 ANALOG UNIT, 8937 VOLTAGE/TEMP UNIT,
8938 FFT ANALOG UNIT, 8939 STRAIN UNIT, 8940 F/V UNIT,
8946 4ch ANALOG UNIT, 8947 CHARGE UNIT
8956 ANALOG UNIT, 8957 HIGH RESOLUTION UNIT,
8958 16ch SCANNER UNIT, 8959 DC/RMS UNIT,
8960 STRAIN UNIT, 8961 HIGH VOLTAGE UNIT
HIOKI 8855
Compatible input units:
8950 ANALOG UNIT, 8951 VOLTAGE/CURRENT UNIT,
8952 DC/RMS UNIT, 8953-10 HIGH RESOLUTION UNIT,
8954 VOLTAGE/TEMP UNIT, 8955 F/V UNIT
HIOKI 8825
Compatible input units:
8907 ANALOG UNIT, 8908 TEMPERATURE UNIT,
8909 FFT ANALOG UNIT
HIOKI 8840
Compatible input units:
8916 ANALOG UNIT, 8917 DC/RMS UNIT,
8918 TEMPERATURE UNIT, 8919 FFT ANALOG UNIT,
8928 STRAIN UNIT
HIOKI 8847, MR8847-01, MR8847-02, MR8847-03, MR8847A,
MR8827, MR8740, MR8741
Compatible input units:
8966 ANALOG UNIT, 8967 TEMP UNIT, 8968 HIGH RESOLUTION
UNIT, 8969 STRAIN UNIT, 8970 FREQ UNIT, 8971 CURRENT UNIT,
8972 DC/RMS UNIT, 8973 LOGIC UNIT, U8974 HIGH VOLTAGE
UNIT, MR8990 DIGITAL VOLTMETER UNIT
1.2 Specifications
HIOKI MR8875, MR8875-30
Compatible input units:
MR8901 ANALOG UNIT, MR8902 VOLTAGE/TEMP UNIT,
MR8903 STRAIN UNIT, MR8904 CAN UNIT, MR8905 ANALOG UNIT
HIOKI MR6000, MR6000-01
Compatible input units:
8966 ANALOG UNIT, 8967 TEMP UNIT,
8968 HIGH RESOLUTION UNIT, 8969/U8969 STRAIN UNIT,
8970 FREQ UNIT, 8971 CURRENT UNIT, 8972 DC/RMS UNIT,
8973 LOGIC UNIT, U8974 HIGH VOLTAGE UNIT,
U8975 4CH ANALOG UNIT, U8976 HIGH SPEED ANALOG UNIT,
U8977 3CH CURRENT UNIT, U8978 4CH ANALOG UNIT,
U8979 CHARGE UNIT, MR8990 DIGITAL VOLTMETER UNIT
HIOKI MR8740T
Compatible input units:
8966 ANALOG UNIT, 8967 TEMP UNIT,
8968 HIGH RESOLUTION UNIT, 8969/U8969 STRAIN UNIT,
8970 FREQ UNIT, 8971 CURRENT UNIT, 8972 DC/RMS UNIT,
8973 LOGIC UNIT, U8974 HIGH VOLTAGE UNIT,
U8975 4CH ANALOG UNIT, U8977 3CH CURRENT UNIT,
U8978 4CH ANALOG UNIT,
U8979 CHARGE UNIT, MR8990 DIGITAL VOLTMETER UNIT,
U8991 DIGITAL VOLTMETER UNIT (4CH)
Loadable data format
MEMORY HiCORDER files
Memory functions ("mem" file extension)
HI-Speed functions ("mem" file extension)
Normal measurement data ("mem" file extension) (only MR6000
MEMORY HiCORDER)
Recorder functions ("rec" file extension)
Realtime functions ("rec" file extension) (only MR8880
MEMORY HiCORDER)
Envelope measurement data ("rec" file extension) (only MR6000
MEMORY HiCORDER)
RMS functions ("rms" file extension)
Power functions ("pow" file extension)
XY Recorder functions ("xyc" file extension) (only 8847
MEMORY HiCORDER)
Maximum loadable file
size
Maximum size handled by supported MEMORY HiCORDER
(The size of files that can be handled may be smaller, depending
on the PC's operating environment.)
Overwrite save
Possible (Existing files can be overwritten with title comments,
channel comments, and scaling data.)
Partial Save
Partially save the waveform data between section-specifying cursor
(excluding MR8875, 8860, MR6000, MR8740T MEMORY
HiCORDER)
Text conversion
Data conversion format
Selectable from CSV format, text (tab separated), text (space
separated), COMTRADE format(1991) or NMEA 0183 format
(COMTRADE format: only MR6000, 8860 MEMORY
HiCORDER)
(NMEA 0183 format: only MR8875 MEMORY HiCORDER)
Applicable data
All data or data between cursors
Data interleaving
Data can be interleaved at fixed intervals
Conversion method
Analog waveform data is converted into voltage values
Pulse waveform data is converted in integration or revolution
values
Logic data is converted into binary values (1 or 0).
Conversion channels
Selectable
Header contents
Title, trigger date/time, time-axis range, comments, setting
conditions for each channel
Collective conversion
Specified multiple files can be converted simultaneously.
Shows waveform data images.
May be scrolled along the time-axis.
May be magnified or compressed along the time-axis.
Allows repositioning of the zero position or
magnification/compression of one channel at a time.
Supports variable settings on each channel.
X-Y synthesis display
Possible in "MEM", "REC" (envelope off) , "POW", or "XYC"
function format.
A range of data to synthesize can be specified.
Digital display
Digital values can be displayed for waveform data.
Cursor function
Two cursors (A and B) can be manipulated independently.
Time value and voltage value display
Maximum displayed
channels
256 analog channels
32 calculation channels
2 pulse channels
128 logic channels
Gauge display
Time gauge (selected from absolute time, relative time, seconds, or
data count)
Voltage-axis gauge (maybe shown or hidden for each separate
channel)
Diagram input
May be entered at any position.
Text, line, arrow, circle, or square
Copy to clipboard
Waveform screen (bitmap format/extended meta format)
Cursor value, digital value, file information, or calculation result
(text format)
Search function
Date/time search, maximum search, minimum search, level search,
or window search
Numerical Calculation
Calculations
Average value, RMS value, P-P value, Maximum value, Time-to-
Maximum value, Minimum value, Time-to Minimum value,
Standard Deviation, Time-to-Specified Level, Area value, Integral
value, Sum, Rise Time, Fall Time, Period, Frequency, Pulse
Width, Duty, On counts, Off counts, On Time, Off Time,
Operating Rate
Calculation Range
All data, specified range, between AB cursor
The printers supported depend on the OS being used.
Color and monochrome print possible
Print range
All data, screen-displayed range, or specified range
Print format
Not divided; divided by 2, 4, 8, or 16; 2, 4, 8, or 16 columns;
XY1 screen, XY2 screen, or XY4 screen
Gauge; channel comments can be set to print
0 position comment, AB cursor value, event mark can be set to print
Print preview
Possible
Waveform screen hard
copy
Possible
Logging print
Possible
Other
Tool function
Any executable file registered can be executed.
Load in sequence
Load a waveform file in the folder in sequence.
2.1 Minimum System Configuration
______________________________________________________________________________________________
NOTE
To load data from the MEMORY HiCORDER into your computer, you must have
PC card, SD card or USB drives. To load waveforms, you must have sufficient free
space on your hard disk for the waveform data.
Chapter 2
Setup
2.1 Minimum System Configuration
The 9335 requires the following hardware and software:
Computer main unit
OS: Windows 7, 8 or 10
1 GHz or faster 32-bit or 64-bit processor, and 2 GB RAM
Minimum free hard disk space: 20 MB (used for installation)
CD-ROM drive (used for installation)
Display unit capable of displaying with a resolution of 1024 x 768 dots or
higher (using small fonts) and 256 or more colors
2.3 Starting and Quitting the Wave Processor
______________________________________________________________________________________________
NOTE
When running another application, you may be unable to install the 9335 software.
Close all applications that can be closed before installing the 9335 software. In
particular, virus protection software may inhibit installation. In such cases, set up
the virus protection software to permit installation.
When upgrading versions, uninstall the old version of 9335 before installing the
new version of 9335. After installation, confirm the version information on the
"Help" menu.
The 9335 software may not be registered on the Start menu, depending on your
computer's operating environment. In such case, start "Wpro.exe" directly from the
folder in which it was installed.
2.2 Installation and Uninstallation
2.3 Starting and Quitting the Wave Processor
Installation
Install the 9335 software by following the procedure below:
1. Close all currently active applications.
2. Insert the CD-R included with your package into the PC's CD-ROM drive.
3. Run the SETUP file from the CD-R.
For example, if your CD-ROM drive is drive R (if not, use the letter
representing the CD-ROM drive on your computer), select "Start" - "Run"
from the Windows
menu, enter R:\9335ENG\setup.exe, then click .
4. This launches the 9335 installer. Follow the instructions displayed on
screen.
Uninstallation
To uninstall the 9335 software, follow the procedure described below:
1. Close all currently active applications.
2. Insert the CD-R included with your package into the PC's CD-ROM drive.
3. Run the SETUP file from the CD-R.
For example, if your CD-ROM drive is drive R (if not, use the letter
representing the CD-ROM drive on your computer), select "Start" - "Run"
from the Windows
menu, enter R:\9335ENG\setup.exe, then click .
4. This launches the 9335 uninstaller. Follow the instructions displayed on
screen.
Starting the Wave Processor
Select "Programs" - "HIOKI" - "9335 Wave Processor" - "9335 Wave
Processor" from the Windows
Start menu.
Quitting the Wave Processor
Select "File" - "Exit" from the Wave Processor menu. Otherwise, click the
close button at the upper-right corner of the main window.
3.1 Loading Waveform Files
______________________________________________________________________________________________
Chapter 3
Waveform Window
3.1 Loading Waveform Files
The waveform window is displayed when you load any waveform file
("mem", "rec", "rms", "pow", or "xyc" file extension) recorded with the
MEMORY HiCORDER.
1. Select "Open Waveform File" from the "File" menu to display the "Open
File" dialog box.
2. Select the desired file to load and click the "Open" button.
About waveform settings files
Closing the loaded waveform file (by clicking the close button at the upper-
right corner of the main window to close all windows) automatically creates
a settings file (".hps" file extension) under the same name as the loaded file
in the same folder containing the loaded file. Opening the waveform file will
now load the settings file automatically, with the saved settings reflected in
the loaded file, provided that a settings file with the same name exists in the
same folder. If you do not want to load these settings, manually delete the
settings file.
Halting waveform drawing
The system may require some time to redraw waveforms representing large
amounts of data. To abort waveform drawing, press the Esc key on the
keyboard. Click the "Update" button on the toolbar to redraw the waveform
window.
Loading large files
Very large waveform files may not be loadable by Windows due to limited
system resources. In such case, close all other active applications, then try
reloading. Depending on the specific configuration of your computer, you
may still be unable to load the waveform file.
3.2 Working in the Waveform Window
______________________________________________________________________________________________
Menu bar
Main toolbar
Main status bar
File name
Voltage-axis
gauge
Waveform
display
Time-axis
gauge
Title
Double-click the
left mouse
button to enter
any desired
character string.
Channel legend
Channel marker
Cursor display
range
Shows the
waveform range
enclosed by
cursors A and B
or interval
cursors.
Waveform screen status bar
Displays from left to right the model name, measurement function,
time-axis range (sampling period), recording length (data counts),
trigger date/time, pretrigger, judgement result and waveform data
display range.
Scroll bar
Lets you scroll the waveform. You can also
use the left/right keys or mouse wheel (for
mouses provided with a wheel) to scroll.
Slide Function
The Slide Function allows you to display waveforms
saved in the same folder one after another in order.
3.2 Working in the Waveform Window
The waveform window is displayed when you load a waveform file.
* For time-axis representation, you can select "DIV" (see Section 3.2.4,
paragraph 5). Data counts per division vary with the MEMORY HiCORDER
model, so refer to the user's manual provided with your model.
3.2 Working in the Waveform Window
______________________________________________________________________________________________
3.2.1 Waveform Window Menu
[File]
[Open Waveform File]: Loads a waveform file.
(See 3.1.)
[Edit]
[Convert All]: Converts all waveform data into text.
(See 4.1.)
[Convert Between Cursors]: Converts a specified section of data into text.
(See 4.2.)
[Batch Conversion]: Converts multiple specified waveform files into text.
(See 4.3.)
[Save Waveform File]: Saves a waveform file over the existing file.
(See 3.1.)
[Screen Print]
[Print]: Prints a waveform screen.
(See 6.1.1.)
[Preview]: Shows a preview of the printed waveform window. (See 6.1.2.)
[Page Settings]: Sets screen print.
(See 6.1.3.)
[Waveform Detail
Print]
[Print]: Prints waveforms in detail.
(See 6.2.1.)
[Preview]: Shows a preview of the detailed print.
(See 6.2.2.)
[Page Settings]: Sets detailed printing.
(See 6.2.3.)
[Printer Settings]: Sets a printer.
[Exit]: Terminates Wave Processor.
[Capture Waveform Screen]: Copies the waveform window to the clipboard.
(See 3.14.)
[Capture Settings] : Sets a screen hard copy. (See 3.14.1.)
[View]
[Waveform View]: Opens another instance of the waveform window.
[Logging View]: Displays waveform data numerically.
(See 3.13.)
[XY View]: Displays waveform data on XY axes.
(See Chapter 5.)
[Time-Axis Cursor]: Displays the Time-Axis Cursor dialog box.
(See 3.3.)
[Volt Cursor]: Displays the Voltage Cursor dialog box.
(See 3.4.)
[Section Cursor]: Displays the Interval Specify Cursor dialog box.
(See 3.5.)
[Waveform Info]: Shows amp and other information for each channel.
(See 3.6.)
[Search]: Displays the Search dialog box.
(See 3.7.)
[Parameter Calculation]: Displays the Numerical Operation dialog box.
(See 3.8.)
[Waveform Control]: Displays the Waveform Operations dialog box.
(See 3.9.1.)
[Toolbar]
[Settings]
[Main Toolbar]: Show/hides the main toolbar.
[Wave Toolbar]: Show/hides the waveform window toolbar.
[Status Bar]
[Main Status Bar]: Show/hides the main status bar.
[Wave Status Bar]: Show/hides the waveform window status bar.
[Graph Settings]: Sets graphic waveform display.
(See 3.2.5.)
[Display Range Settings]: Sets a range of data to be displayed in the waveform window. (See 3.2.6.)
[CH Settings]: Sets channel comments and scaling.
(See 3.10.)
[Window]
[New Window]: Opens another instance of the same window as the currently active window.
[Cascade]: Displays all windows in overlapping format.
[Tile]: Displays all windows one below another.
[Arrange Icons]: Lines up the minimized windows.
[Close]: Closes the currently active window.
[Close All]: Closes all windows.
[Help]
[About 9335 Wave Processor]
[Template]: Save or load a template file.
[Set Tools]
[Tools]
The waveform window contains the following menus:
3.2 Working in the Waveform Window
______________________________________________________________________________________________
3.2.2 Main Toolbar
1. 2. 3. 4. 5. 6. 7.
11.12. 13.14.15.16.
17.18.19.20. 21. 22.
8. 9. 10.
This is the toolbar in the main window.
All functions of the main toolbar are available in menus.
1. Open Waveform File
Loads a waveform file. Click the arrow to the right of this button to see a
list of previously loaded files.
2. Convert All
Converts the entire range of waveform data into text.
3. Convert Between Cursors
Converts a specified section of data into text.
4. Batch Conversion
Converts multiple specified files into text.
5. Automatically Load a Template File
Load a waveform display condition template file automatically at loading a
waveform file.
6. Load a Template File
Load a waveform display condition template file.
7. Save a Template File
Save a waveform display conditions to a template file.
8. Screen Print
Prints a waveform screen.
9. Waveform Detail Print
Prints a waveform in detail.
10. Waveform View
Opens another instance of the waveform window.
11. Logging View
Displays waveform data numerically.
12. XY View
Displays waveform data on XY axes.
13. Time-axis Cursor
Displays the "Time-Axis Cursor" dialog box.
14. Volt Cursor
Displays the "Volt Cursor" dialog box.
15. XY Cursor
Displays the "XY Cursor" dialog box.
16. Section Cursor
Displays the "Section Cursor" dialog box.
17. Waveform info
Shows amp and other information for each channel.
18. Search
Displays the "Search" dialog box.
19. Parameter Calculation
Displays the "Parameter Calculation" dialog box.
20. Waveform Control
Displays the "Waveform Control" dialog box.
21. Tools
Allows you to start other applications. (For more information, see 3.11, "Using Tools".)
22. Exit
Terminates Wave Processor.
3.2 Working in the Waveform Window
______________________________________________________________________________________________
3.2.3 Waveform Window Toolbar
1.
2.
3.
5.
6.
7.
8.
9.
10. 11.
12. 13.
14.
4.
This is the waveform window toolbar.
1. Zoom Out / In
Magnifies/compresses the time axis of the waveform screen.
2. Cursor A Operation Mode
Left-click (the left mouse button) anywhere in the waveform display area
when this button is enabled to move cursor A to that position. Hold down
the
Shift key and left-click to move the voltage A cursor to that position.
3. Cursor B Operation Mode
Left-click anywhere in the waveform display area when this button is
enabled to move B to that position. Hold down the
Shift key and left-click
to reposition the voltage B cursor.
4. Section Start Cursor Operation Mode
Left-click anywhere in the waveform display area when this button is
enabled to reposition the interval start cursor.
5. Section End Cursor Operation Mode
Left-click (the left mouse button) anywhere in the waveform display area
when this button is enabled to reposition the interval end cursor.
6. Comment Operation Mode
When this button is enabled, you can enter or edit comments. The comments
do not track waveforms when scrolled.
How to enter comments
(1) Click the comment input operation mode button on the toolbar.
(2) Drag the mouse in the waveform display area (by holding down the left
mouse button and moving the mouse) to set the size of the comment
input box. Enter a character string in the comment box.
(3) After entering a comment, left-click outside the comment box to finish
entering comments.
(4) After entering comments, you can move the comment by dragging to
another position.
(5) To edit existing comments, point to the desired comment and double-
click the left mouse button while the comment input operation mode
button on the toolbar is enabled. Otherwise, right-click the desired
comment to display a popup menu, then use the popup menu to change
character colors and other display parameters.
7. Waveform Zoom Operation Mode
Left-click anywhere in the waveform display area when this button is
enabled to magnify the time axis, centering on that position. Otherwise, hold
down the
Shift key and left-click to compress the time axis.
8. Display Cursor A
Shows or hides cursor A.
9. Display Cursor B
Shows or hides cursor B.
10. Display Volt Cursor A
Shows or hides voltage-axis cursor A.
3.2 Working in the Waveform Window
______________________________________________________________________________________________
3.2.4 Popup Menu
1.
4.
5.
3.
8.
7.
6.
2.
9.
11. Display Volt cursor B
Shows or hides voltage-axis cursor B.
12. Graph Settings
Sets a waveform graph. (See 3.2.5.)
13. Split
The waveform window can be split into as many as four sections. An
approximate dividing line is shown in the window when you click the split
window button, so left-click at the appropriate position. This is convenient
when, for example, you want to observe the beginning and the ending parts
of the same waveform at the same time. Click the split window button again
to restore single-window display.
14. Update
Updates the waveform window.
Right-click anywhere in the waveform window to display a popup menu.
1. Gauge display
Gauge Type Select the display method for the gauge from the following:
None No gauges are displayed.
Upper/Lower For channels that have gauges turned on, the gauge for the
channel with the smallest number is displayed. Voltage values are
displayed only above and below the gauge.
Detail For channels that have gauges turned on, the gauge for the channel
with the smallest number is displayed. Voltage values are displayed for
every five divisions.
Multiple For channels that have gauge display turned on, gauges are
displayed for as many channels as specified by gauge counts, beginning
with the channel with the smallest number. Voltage values are displayed
3.2 Working in the Waveform Window
______________________________________________________________________________________________
only above and below the gauge.
Multi-Detail
For channels that have gauge display turned on, gauges are
displayed for as many channels as specified by gauge counts, beginning
with the channel with the smallest number. Voltage values are displayed
for every division.
Show Zero Position Shows or hides zero position marker.
Gauge Counts For multiple gauge types, set the number of gauges you
want to display.
Channel Changes the display of channel information.
Numeric Format Changes the display method for voltage values.
Resize Changes the size (width) of the gauge display area. The display area
is enclosed in dotted lines. Drag the left and right-side squares (located near
the center of the area) to resize as desired.
Text Color Set the colors of the numeric values of the gauge.
Font, Vertical Font Set the fonts for the characters displayed on the gauge.
2. Marker display
Cursor A to Search History marker Set to show or hide each marker.
Jump Scrolls the waveform window to a specified position.
3. Title
Edit Edit the title character string.
Transparent Makes the background transparent.
Border Displays the border.
Text Color to border color 2 Changes the display color for each element.
Resize Changes the size (height) of the title display area. The display area is
enclosed in dotted lines. Drag the square located near the center of the
display area to resize as desired.
Font Changes the title font.
Property Sets the border color, style, etc.
4. Waveform display window
Zoom In, Zoom Out Magnifies or compresses the window along the time-axis.
You can also select the time per division. Selecting All compresses the
waveform to fit in the window.
Show Waveform Shows or hides analog, pulse and logic waveforms
simultaneously.
Divide Graph Up to 16 graphs can be displayed.
Grid Shows or hides the horizontal line, horizontal auxiliary line, vertical
line, and vertical auxiliary line.
Jump Scrolls the waveform to the trigger point, post trigger point, cursor A
or B position, start or end position of an interval, or search position.
Color Sets waveform background color, grid line color, and auxiliary line
color.
5. Time-axis display
Type Select the method of displaying the time axis from the following:
None Does not show time.
Upper/Lower Shows the time at both ends of the window.
Detail Shows the time at every 5 divisions.
Time Notation Sets the method of displaying time. Select from Date, Trigger
Time, Second, Data Number, or Div.
Resize Changes the size (height) of the time-axis display area. The display
area is enclosed in dotted lines. Drag the square located near the center of
the display area to resize as desired.
Text Color, Font Change the character color and font.
3.2 Working in the Waveform Window
______________________________________________________________________________________________
6. Display cursor status
Show Cursor Status Shows or hides the cursor range.
AB Cursors Status Color, Section Cursor Status Color Set colors for each cursor
status.
7. Channel marker
Type Sets the content to be displayed for the channel marker.
Analog CH Marker, Pulse CH Marker, Logic CH Marker Shows or hides the
respective channel markers.
Resize Changes the size (width) of the channel marker display area. The
display area is enclosed in dotted lines. Drag the square located near the
center of the display area to resize as desired.
Text Color, Font Sets the character color and font used in the channel marker.
8. Waveform window periphery
Set Display Range (See 3.2.6.)
Zoom In, Zoom Out Magnifies or compresses the window along the time-axis.
Split Window The waveform window can be split into as many as four
sections. Equivalent to Split Window on the waveform toolbar.
Refresh Redraws the waveform window.
Show Shows or hides each display area.
Template Save or load a template file.
Capture Produces a hard copy of the screen according to the settings set in
Section 3.14.1, "Setting Hard Copy", which can then be pasted onto other
applications.
Background Color Set the window background color.
Toolbar, Status bar
Shows or hides each bar.
9. Display waveform legend
Channel Changes the display of channel information.
Show Waveform Shows or hides analog, pulse and logic waveforms
simultaneously.
Resize Changes the size (width) of the waveform legend display area. The
display area is enclosed in dotted lines. Drag the left and right-side squares
(located near the center of the display area) to resize as desired.
Text Color, Font Sets the character color and font of the waveform legend.
Hold down the
Shift key while right-clicking any channel to display a
menu described below.
Waveform Controll Displays the waveform operation window.
Show Waveform, Display Gauge Shows or hides waveforms or gauges.
(Gauges can only be displayed for analog or pulse waveforms.)
Waveform Color Sets waveform colors.
Graph Selects a graph to display the waveform.
Line Width Selects the line width of waveforms. (Available for analog or
pulse waveforms only)
Position Sets the logic waveform display position. (Available for logic
waveforms only)
Top Draws the waveform of the selected channel on top of all other
waveforms. (Available for analog waveforms only)
Hold down the
Ctrl key while right-clicking any channel to set waveform
color.
3.2 Working in the Waveform Window
______________________________________________________________________________________________
3.2.5 Setting Waveform Graphs
6.
1.
2.
3.
4.
5.
7.
8.
9. 10.11. 12.
Set the display method for waveform graphs.
Click the "Set Graph" button on the waveform window toolbar or select "Set
Graph" from the "Settings" menu to display the "Waveform Graph Settings"
dialog box.
1. OK button
The new settings are reflected in the graph. The dialog box is closed.
2. Cancel button
The new settings are canceled (i.e., not reflected in the graph). The dialog
box is closed.
3. Apply button
The new settings are reflected in the graph, but the dialog box is not closed.
4. Select number of divided graphs
The graph can be divided vertically into as many as 16 smaller windows.
* Depending on the window size, not all graphs may be displayed.
5. Select gauge type
Select the voltage-axis gauge from "None", "Upper/Lower", "Detail",
"Multiple", or "Multiple-Detail".
None No gauges are displayed.
Upper/Lower For channels that have gauge display turned on, the gauge for
the channel with the smallest number is displayed. Voltage values are
displayed only above and below the gauge.
Detail For channels that have gauge display turned on, the gauge for the
channel with the smallest number is displayed. Voltage values are displayed
at every five divisions.
Multi For channels that have gauge display turned on, gauges are displayed
for as many channels as specified by gauge counts, beginning with the
channel with the smallest number. Voltage values are displayed only above
and below the gauge.
Multi-Detail For channels that have gauge display turned on, gauges are
displayed for as many channels as specified by gauge counts, beginning
with the channel with the smallest number. Voltage values are displayed for
every division.
6. Gauge counts
For multiple gauge types, set the number of gauges you want to display. For
3.2 Working in the Waveform Window
______________________________________________________________________________________________
13.
14.
3.2.6 Setting Display Ranges
channels that have gauge display turned on, gauges are displayed for
channels sequentially, beginning with the channel with the smallest number.
7. Channel select tab
Select the channels you want to set.
8. Show/hide channel
Select the check box for any channel to display the waveform for that
channel.
9. Waveform color setting button
Set the waveform color for each channel.
10. Show/hide voltage gauge
Select the check box for any channel to display the voltage gauges for that
channel. The number of gauges that can be displayed is limited by the gauge
type and gauge count set.
11. Select display graph
If the graph is divided, select a graph to use to display the waveform for
each channel.
12. Select line width
Select the line width of waveforms.
If you selected logic channels on the channel select tab, the
dialog box includes the following set items:
13. Select display graph
If the graph is divided, select a graph you want to use to display the logic
waveform for each logic unit.
14. Select display position
Select the position at which to display the logic waveform for each logic
unit. If the graph is not divided, the top is "Posn1" and the bottom is
"Posn8". The number of positions that can be set varies with the number of
divided graphs.
You can set a range of waveform data you want displayed in the waveform
window. If you are loading waveform data for the first time, the entire range
of data is displayed.
Select "Change Display Range" from the "Settings" menu to display the "Set
Waveform Display Range" dialog box. Otherwise, double-click the "waveform
3.3 Time-Axis Cursors
______________________________________________________________________________________________
1.
2.
3.
4.
5.
6.
3.3.1 Manipulating Cursors
3.3 Time-Axis Cursors
data display range" area on the waveform window status bar to invoke the
dialog box.
The dialog box initially displays a range of data enclosed by the interval-
specifying cursor.
1. Display specifiable range
2. Set start point
Set the first point of the waveform data you want to display. The relative
time at that point (time from the trigger) is shown to the right.
3. Set end point
Set the last point of the waveform data you want to display. The relative
time at that point is shown to the right.
4. Reset button
The start and end points are reset to the entire data range.
5. OK button
The new settings are reflected in the graph. The dialog box is closed.
6. Cancel button
The new settings are canceled (i.e., not reflected in the graph). The dialog
box is closed.
The time-axis cursors let you read the voltage values at the cursor positions
on each channel.
Click the "Display cursor A" or "Display cursor B" button on the waveform
toolbar to display time-axis cursors on the screen.
To move a cursor, drag the cursor marker or cursor in waveform window (by
holding down the left mouse button while dragging). Otherwise, click the
"Cursor A operation mode" or "Cursor B operation mode" button on the
waveform toolbar, then left-click at the desired position in the waveform
window.
3.3 Time-Axis Cursors
______________________________________________________________________________________________
Cursor markers
Cursor B
Cursor A
3.3.2 Displaying the Time-Axis Cursor Dialog Box
1.
1.
2.
2.
3.
4.
5.
6.
To read the time value at the cursor position and the voltage value on each
channel, display the Time-Axis Cursor dialog box.
Click the "Display time-axis cursor window" button on the main toolbar to
display the "Time-Axis Cursor"dialog box, or select "Time-Axis Cursor" from
the "Settings" menu to display the dialog box. Drag the edge of the dialog
box to resize.
1. Time value display
Shows the time value at the cursor position. Shown below is the frequency
for the time from the beginning of waveform data.
2. Button for moving the cursor
3. Cursors A & B time difference display
Shows the time difference between cursors A and B. Shown below is the
frequency for the time difference.
4. Button for moving cursors A and B simultaneously
5. Search position display
Shows the time value as search result. Shown below is the frequency from
the beginning of waveform data to the search position. (Refer to Section 3.7,
"Searching Waveform Data")
6. Voltage value display
Shows the voltage values at the positions of cursors A and B on each
channel, and the difference in voltage values between both cursors. If search
results are available, the voltage values at search positions are also displayed.
Voltages on logic channels are indicated by binary values (1 or 0).
Popup menu
Right-click in the dialog box to display a popup menu.
Copy cursor position Copies the time values at the cursor positions to the
clipboard (from where they can be pasted onto "Notepad" or other
applications).
Copy selected channel Copies the voltage values on selected channels in the
voltage value display area to the clipboard. Left-click to select a channel.
Hold down the Ctrl or Shift key while left-clicking to select multiple
3.4 Voltage Cursors
______________________________________________________________________________________________
3.4.1 Manipulating Cursors
Cursor markers
Cursor B
Cursor A
3.4.2 Displaying the Voltage Cursor Dialog Box
1.
2.
1.
2.
3.
4.
5.
5.
3.4 Voltage Cursors
channels.
Copy all Copies the time values at cursor positions and the voltage values for
all channels to the clipboard.
Numeric display Sets the format in which to show voltage values. Select from
"Exponential", "Floating-point", or "Auxiliary unit". Display of the unit of
measure can be turned on or off.
Maximum value/minimum value, Mean value May be selected when the type of
waveform data is the recorder function (".rec" file extension), realtime
function (".rec" file extension) (envelope on) or rms value function (".rms"
file extension). The voltage values are shown as maximum and minimum
values, or as a mean value.
Move to search position Moves cursor A or B to the search position.
The voltage cursors let you read the voltage values for specified channels.
Click the "Display voltage cursor A" or "Display voltage cursor B" button on
the waveform toolbar to display voltage cursors on screen.
To move the cursor, drag the cursor marker or cursor in the waveform
window (by holding down the left mouse button while dragging). Otherwise,
click the "Cursor A operation mode" or "Cursor B operation mode" button on
the waveform toolbar and hold down the
Shift key as you left-click at an
appropriate position in the waveform window to move the cursor.
To read the voltage values at cursor positions, display the "Volt Cursor"
dialog box. Click the "Display voltage cursor window" button on the main
toolbar to display the dialog box, or select "Volt Cursor" from the "View"
menu to display the dialog box.
1. Time value display
Shows the voltage values for specified channels.
2. Button for moving the cursor
3. Cursors A & B voltage difference display
Shows the voltage difference between cursors A and B.
3.5 Interval-specifying Cursors
______________________________________________________________________________________________
3.5.1 Manipulating Cursors
Interval end cursor marker
Interval start cursor marker
3.5.2 Displaying the Interval-specifying Cursor Dialog Box
1.
2.
3.
4.
5.
6.
7.
8.
9.
3.5 Interval-specifying Cursors
4. Button for moving cursors A and B simultaneously
5. Select channel
Select the channel whose voltage you want to see.
Popup menu
Right-click in the dialog box to display a popup menu.
Copy cursor value Copies the voltage values at cursor positions to the
clipboard (from where they can be pasted onto "Notepad" or other
applications).
Exponential, Floating-point, Auxiliary unit Sets the format in which voltage
values are displayed.
Show unit Turns the displayed unit of measure on or off.
Use the interval-specifying cursors to specify an interval from the beginning
to the end point of a waveform when performing text conversion, numerical
operations, or searches.
Interval-specifying cursors are displayed by default. If such cursors are not
displayed, right-click in the marker display area and select "Section Cursor"
from the popup menu.
To move the cursor, drag the cursor marker (by holding down the left mouse
button while dragging). Otherwise, click the "Interval start cursor operation
mode", or "Interval end cursor operation mode" button on the waveform
toolbar and click at an appropriate position in the waveform window to
move the cursor.
Displaying the Interval-specifying Cursor dialog box lets you read the exact
positions of the interval-specifying cursors. You can also finely adjust the
cursor positions.
Click the "Display interval-specifying cursor window" button on the main
toolbar to display the "Section Cursor" dialog box, or select "Section Cursor"
from the "View" menu to display the dialog box.
3.7 Searching Waveform Data
______________________________________________________________________________________________
3.7.1 Search by Date/time
3.6 Waveform Information Dialog Box
3.7 Searching Waveform Data
1. Interval start cursor position time value display
Shows the time value at the interval start cursor position.
2. Button for moving the interval start cursor
3. Interval end cursor position time value display
Shows the time value at the interval end cursor position.
4. Button for moving the interval end cursor
5. Interval-specifying cursors time difference display
Shows the time difference between the interval-specifying cursors.
6. Button for moving the interval-specifying cursors simultaneously
7. Shows data counts within the interval. Use this value as an approximate
amount of data when performing text conversion.
8. Interval start icon
9. Interval end icon
Popup menu
Right-click the interval start or interval end icon to display a popup menu.
You can use this popup menu to move the interval start or interval end
cursor to the position of cursor A or B, the beginning or ending position of
an interval, or the trigger or post trigger position, or search position.
The information dialog box shows settings information for each channel.
Click the "Display waveform information window" button on the main toolbar
to display the dialog box, or select "Waveform Information" from the "View"
menu.
Popup menu
Right-click in the dialog box to display a popup menu.
Copy selected range Copies a selected range of information to the clipboard
(from where the information can be pasted onto Notepad or other
applications). Left-click to select a range. To select multiple ranges, hold
down the
Ctrl or
Shift key while left-clicking.
Copy all Copies all information to the clipboard.
You can search for waveform data by date/time, maximum/minimum value,
or voltage level. If you execute a search, the waveform window scrolls until
the search position is reached, with a search marker shown at the top of the
waveform window. The time value and voltage value at the search position
are displayed in the "Time-Axis Cursor" dialog box.
Click the "Display search window" button on the main toolbar to display the
Search dialog box, or select "Search" from the "View" menu.
3.7 Searching Waveform Data
______________________________________________________________________________________________
search button
1.
2.
3.
3.7.2 Search by Maximum, Minimum, Maximal, or Minimal
Value
Specify a date/time or a time from the trigger before you search.
1. Click the "DATE/TIME" tab of the Search dialog box to display the date/time
search window.
2. Enter any date/time or time from the trigger. "Date" and "Trigger time" are
interlocked.
3. Click the search button.
4. Click the Reset button to set the date/time at the trigger position.
Searching for event marks
If the waveform data contains an event mark, you can search for the position
of the event mark. The position of the specified event mark number is
displayed for "Date" and "Trigger time" in the dialog box.
1. Event mark search check box
Selecting this check box lets you search for an event mark.
2. Event mark number input
Specify an event mark number. The position of the specified event mark
number is displayed for "Date" and "Trigger time" in the dialog box. The
event mark of the specified number in the waveform window is indicated by
an asterisk.
3. Event mark range
You can search for maximum/minimum position or the maximal/minimal
position (convex/concave) on a specified channel.
3.7 Searching Waveform Data
______________________________________________________________________________________________
backward search button
3.7.3 Search by Level
search button
backward search button
1. Click the "MAX/MIN" tab of the Search dialog box to display the
maximum/minimum search window.
2. Set the range of search.
ALL Entire range of the waveform data
Selection Data in a section of waveform specified with interval-specifying
cursors
3. Select the method and channel. For maximal/minimal value searches, you
must also select a filter (in DIV units). The search uses moving-averaged
data (moving-averaged over as many divisions as specified for the filter).
This is useful when the waveform contains noise. If there are two or more
maximum or minimum values, the first maximum or minimum position
found by the search is used.
4. Click the search button to jump to the search position.
5. For maximal/minimal search, the system searches for the next point (to the
right) from the current search position each time you click the search button.
To repeat the search from the beginning of the waveform, click the Reset
button.
6. Click the backward search button during maximal/minimal search to, search
for the previous point (to the left) from the current search position.
You can search the position at which the waveform crosses a specified
voltage level (level-up or level-down) or the position at which the waveform
falls in or out of a specified voltage range.
1. Click the "LEVEL" tab of the Search dialog box to display the level search
window.
3.8 Numerical Operation
______________________________________________________________________________________________
Calculation setting
button
Calculation execute
button
3.8 Numerical Operation
2. In the channel list, select the check box for the channel you want to search.
Multiple channels can be selected.
3. Select a search condition. Note that search results differ when multiple
channels are selected, depending on the search condition.
OR A point at which conditions are met for one of the selected channels
AND A point at which conditions are met for all of the selected channels
4. Set the search method for each selected channel. Left-click any desired
channel in the channel list to display the settings for that channel to the
right, allowing you to select the search method.
Level Up A point at which the waveform crosses the voltage specified for
"LEVEL" in the upward direction
Level Down A point at which the waveform crosses the voltage specified by
"LEVEL" in the downward direction
Window-in A point at which the waveform falls within the voltage range
specified by the upper and lower-limit values
Window-out A point at which the waveform goes out of the voltage range
specified by the upper and lower-limit values
If the selected channels are logic channels, specify a logic pattern.
High A point at which the data has the binary value of 1
Low A point at which the data has the binary value of 0
If you set a filter, no search is made unless the condition continues for as
many divisions as set for the filter. This is useful when the waveform
contains noise.
Click the Reset button to deselect the check boxes for all channels and to
reset the search method to the initial setting.
5. Click the search button to jump to the search position.
6. Each time you click the search button, the system searches for the next point
(to the right) from the current search position. To repeat the search from the
beginning of the waveform, click the "Reset" button.
7. Click the backward search button to search for the previous point (to the
left) from the current search position.
Various calculations can be performed.
Click the "Parameter Calculation" button on the main toolbar to display the
"Parameter Calculation" dialog box, or select "Parameter Calculation" from
the "View" menu. Drag the edge of the dialog box to resize.
For the recorder function, realtime function (envelope on) or rms value
function waveform data, calculations can be performed to find the "average
value, rms (root mean square) value, peak-to-peak value, maximum value,
3.8 Numerical Operation
______________________________________________________________________________________________
3.8.1 Setting Calculations
AVE =
n
Σdi
i = 1
1
n
RMS =
n di2
Σ
i = 1
1
n
time for maximum value, minimum value, time for minimum value, standard
deviation, and time for level".
Set the calculation you want to perform and the channel on which you want
the calculation to be performed. In standard settings, all kinds of calculations
are performed on all channels.
1. Click the calculation setting button to invoke the "Calculation Settings"
dialog box.
2. Select the check box for the calculation you want to perform.
Each calculation item is detailed below.
(1) Average value
Calculates the average value (V) of the waveform data.
AVE
average value
n
number of data samples
di
i-th data of the source channel
(2) RMS value
Calculates the RMS (effective) value (V) of the waveform data. When
scaling is used, the value is calculated after scaling.
RMS
effective value
n
number of data samples
di
i-th data of the source channel
(3) Peak-to-peak value
Calculates the peak-to-peak (maximum-minimum) value of the waveform
data.
(4) Maximum value
Calculates the maximum value of the waveform.
(5) Time for maximum value
3.8 Numerical Operation
______________________________________________________________________________________________
n
σ =
{
(di - AVE)2/n}
i = 1Σ
n
S =
| d i |
h
i = 1Σ
Cursor A
Cursor B
Shaded area is calculated
Calculates the time interval to the maximum value of the waveform (in
seconds).
If there are two maximum value points, the time to the first point is
calculated.
(6) Minimum value
Calculates the minimum value of the waveform.
(7) Time to minimum value
Calculates the time interval to the minimum value of the waveform (in
seconds).
If there are two minimum value points, the time to the first point is
calculated.
(8) Standard deviation
Calculates the standard deviation (V) of the waveform data.
σ
standard deviation
AVE
average value
n
number of data samples
di
i-th data of the source channel
(9) Time for level
This operation searches from the beginning of the calculation range for the
point at which the waveform crosses the specified level, then finds the time
from the trigger at that point.
(10) Area value
Calculates the area bordered by the signal waveform and the zero position
(potential 0 V).
S
Area value
n
number of data samples
di
i-th data of the source channel
h = Δt sampling period
(11) Rise time
(12) Fall time
From the captured waveform data, the 0% and 100% level is determined,
and the rise time (s) is taken as the time required to go from 10% to 90%
(fall time: from 90% to 10%).
3.8 Numerical Operation
______________________________________________________________________________________________
90%
10%
Fall time
Rise time
Duty Ratio
x 100 (%)
Tu-d
Tu-d + Td-u
In the captured waveform data, the first rising slope (or falling slope) is used
to make the calculation.
When range cursors are used, the time calculated here is for the first
occurrence of a rising slope (falling slope) in the waveform interval enclosed
by the cursors.
It is possible to set values of the rise time (10% to 90%) and of the fall
time to (90% to 10%).
(13) Period
(14) Frequency
Displays the period (s) and frequency (Hz) of the signal waveform.
The calculation is performed by determining the middle point of the signal
amplitude and then measuring the interval from the point when that level is
crossed (in rising or falling direction) to the point when it is next crossed.
(15) Pulse width
Calculates the time difference between the point where the rising or falling
waveform intersects the set level and the intersection of the next opposite
slope.
(16) Duty Ratio
The ratio is calculated according to the time difference between the point
where the rising waveform intersects the set level and the intersection of the
next opposite slope. It can also be calculated according to the time difference
between the point where the falling waveform intersects the set level and the
intersection of the next opposite slope.
Tu-d: Time from rise to fall (s)
Td-u: Time from fall to rise (s)
(17) ON counts, OFF counts
This operation counts the number of times the signal has crossed the set
level upward or downward.
(18) ON time, OFF time, Operating Rate
This operation finds the time for which the signal remains above the set
level (ON time) and the time for which it remains below the set level (OFF
time).
3. Select the check box for a channel to be calculated.
4. Set each channel. Left-click any desired channel in the channel list to
display settings for that channel to the right.
Slope This parameter is used when calculating time for level, period,
frequency, pulse width, duty cycle, ON counts and OFF counts.
Filter, Level These parameters are used when calculating time for level,
3.8 Numerical Operation
______________________________________________________________________________________________
3.8.2 Executing Calculations
Calculation
setting button
Calculation
execute button
period, frequency, pulse width, duty cycle, ON counts, OFF counts, ON
time, and OFF time. Calculations are performed with respect to the specified
level. The signal is not assumed to have crossed the level until it remains
above or below the level as long as set for Filter.
Rise/fall This parameter is used when calculating the rise time and fall time.
If you set 20% here, the rise time is defined as a 20% to 80% rise time: the
fall time is defined as a 80% to 20% fall time.
5. Click "OK" to reflect the new settings.
6. Click the "Save" button to save calculation settings. Enter a name for the
calculation settings, then click "OK".
7. Click the Load button to load previously saved calculation settings. Select
the settings name you want to load, then click "Load" Click "Delete" to
delete the selected settings.
Execute numerical operations on a selected range of waveform data as
follows:
1. Set a range of waveform data in which you want to perform calculations.
ALL Entire range of waveform data
Selection Data in a section of waveform specified with interval-specifying
cursors
AB Cursor Data in a section of waveform specified with AB cursors.
2. Click the calculation execute button.
3. Right-click in the calculation dialog box to display a popup menu.
3.9 Manipulating the Waveform on Each Channel
______________________________________________________________________________________________
3.9.1 Waveform Operations
3.9 Manipulating the Waveform on Each Channel
Copy selected range Copies the calculation results for a selected range of
waveform to the clipboard (from where they can be pasted onto "Notepad" or
other applications). Left-click to select a range. To select multiple ranges,
hold down the
Ctrl or
Shift key while left-clicking.
Copy all Copies all calculation results to the clipboard.
Floating-point display Shows the calculation results in floating-point format.
Exponential display Shows the calculation results in exponential format.
Auxiliary Unit display Shows the calculation results with auxiliary unit.
This section explains how to manipulate the waveform in each section. Click
the "Display waveform operation window" button on the main toolbar to
display a waveform operation dialog box, or select "Waveform Control" from
the "View" menu to display the dialog box.
Drag the edge of the dialog box to resize.
You can magnify or compress the waveform on each channel and move the
zero position of the waveform. The zero position is defined to be 0% at the
bottom of the graph, 100% at the top of the graph, and 50% at the center of
the graph.
Left-click the desired channel to display the channel settings on the right.
1. Changing the magnifying factor and zero position
You can select the option "Zoom/Position" to set a magnifying factor and
zero position. This also displays the upper and lower-limit values of the
graph.
Change magnifying factor Select from the magnifying factor select box.
Move position Enter a value in the zero position input box, then press the
Enter
key. You can also use the up/down buttons or slider to enter a value.
The colored range of the slider represents the upper and lower limits in the
window (0% to 100%).
2. Setting the upper and lower-limit values of the waveform window
When the option "Variable" is selected, you can set the lower-limit voltage
values of the waveform window. Clicking the Reset button sets the
magnifying factor and the zero position to x1 and 50%, respectively.
Upper-limit/Lower-limit values Enter a voltage in the upper-limit value or
lower-limit value input box, then press the
Enter
key. The zero position
and unit/DIV are immediately changed.
Display range/DIV, Zero position Enter a voltage in the "Range/DIV" input box,
3.9 Manipulating the Waveform on Each Channel
______________________________________________________________________________________________
3.9.2 Setting Others
Change waveform color
Show/hide waveform
Invert waveform
then press the Enter key. Enter the zero position as a percentage in the
"Position" input box, then press the
Enter
key. The upper-limit and lower-
limit values change immediately.
1. Show/hiding waveforms
You can choose to show or hide the waveform for any channel by selecting
the check box for that channel in the channel list.
2. Changing waveform colors
You can change the waveform color for any channel by clicking the icon for
that channel in the channel list.
3. Drawing a waveform on top (analog waveforms only)
Point to any channel in the channel list and double-click the left mouse
button. The selected waveform is displayed on top of all other waveforms in
the waveform window. This facility should prove helpful when multiple
waveforms overlap and you have difficulty viewing a particular waveform.
4. Copying channel setting
The same settings (magnifying factor, zero position, and variable) for a
channel are easily copied and set for other channels.
Specify source to copy Select the channel from which you want to copy and
click the right mouse button. Select "Copy CH Settings" from the ensuing
popup menu.
Reflect settings in other channels Select the channel to which you want
settings to be copied and click the right mouse button. Select "Paste CH
Settings" from the popup menu.
5. Invert waveform (analog waveforms only)
Select the check box to invert the plus and minus sides of the waveform.
3.10 Setting Scaling and Channel Comments
______________________________________________________________________________________________
3.10.1 Setting Scaling
3.10 Setting Scaling and Channel Comments
This section explains how to set scaling and comments for each channel.
Select "CH Settings" from the "Settings" menu to display a "Channel
Settings" dialog box. Use the channel select tab in this dialog box to select
the channel for which you want to enter settings. After setting scaling and
comments for that channel, click the OK or Apply button to reflect your
settings.
* The scaling and channel comments are reflected in the waveform, logging,
and XY synthesis windows currently open for the same waveform file.
The scaling function lets you convert voltages into a physical quantity to be
measured. The gauge divisions and cursor readouts display scaled values.
1. Set by conversion ratio
Set the physical quantity per V (EU/V), an offset, and a unit name so that
voltage values are converted into the corresponding value in units you have
set. After selecting "Ratio" for the scaling method, enter your desired
conversion ratio, offset, and unit name.
2. Set by two points
Set the voltage values at two points and set the conversion values and unit
names for the respective points before performing conversion. After selecting
"Point" for the scaling method, enter the pre-conversion voltage values at
two points and the post-conversion values and unit names for the respective
points.
3.11 Using Tools
______________________________________________________________________________________________
3.10.2 Setting Channel Comments
3.11.1 Registering Applications
3.11.2 Executing the Tool
3.11 Using Tools
Channel comments set with the MEMORY HiCORDER can be edited.
Comments are displayed in the waveform window, detail print, and various
settings windows. Enter a character string in the "Comment" input box
provided for each channel.
Any application can be registered to the tool button, and once registered can
be launched simply by clicking the button.
You can register up to five applications to the tool button.
Select "Set Tools" from the "Tools" menu, and the "Set Tools" dialog box is
displayed. Or click the arrow to the right of the tool button on the toolbar
and select "Set Tools" from the resulting menu.
After setting up the tool, click OK.
1. Name
Enter the name of the application.
2. Command line
Enter the execution file of the application.
3. Parameter
Enter the parameter or file name which is to follow the execution command.
4. Folder
Enter the runtime directory of the application.
Before you can execute the tool, you must have at least one application
registered to it.
Select the "Tools" menu or click the arrow to the right of the tool button on
the toolbar. The registered applications are listed on the menu. Select an
application, or click the tool button to invoke the previously used
application.
3.13 Numeric Display of Waveform Data
______________________________________________________________________________________________
Logging window
status bar
Title of the reference waveform window
3.12 Saving Waveform Data over Existing Data
3.13 Numeric Display of Waveform Data
Title comments, channel comments, and scaling can be saved over the
existing data.
Select "Save Waveform File" from the "File" menu to save these settings over
the existing file.
* Because the previous settings are deleted when saved over the existing file,
be sure to produce a backup of the file beforehand.
The loaded waveform data can be displayed numerically. The data for analog
channels are represented by voltage values (if scaling is turned on, by scaled
voltage values), the data for pulse channels are represented by integration or
revolution values (if scaling is turned on, by scaled values), while the data
for logic channels is represented by binary 0 and 1.
Select "Logging Window" from the "View" menu, or click the "Display
logging window" button on the toolbar. A logging window is displayed.
Multiple logging windows can be displayed by repeating this procedure.
If a logging window is displayed while the waveform window is active, the
logging window will contain the active waveform window cursors. The
logging window status bar shows the title name of the waveform window
being referenced. If a display range was set for the waveform window, that
range of waveform is logging-displayed. (See 3.2.6.)
3.13 Numeric Display of Waveform Data
______________________________________________________________________________________________
3.13.1 Logging Window Menus
[File]
[Open Waveform File]
[Edit]
[Convert All]
[Convert Between Cursors]
[Batch Conversion]
[Printer Settings]
[Exit]
[Copy] : Copies a selected range of numeric values to the clipboard. (See 3.13.3.)
[View]
[Waveform View]
[Logging View]
[XY View]
[Waveform Info]
[Toolbar]
[Settings]
[Main Toolbar]
[Logging Toolbar]
[Status Bar]
[Main Status Bar]
[Logging Status Bar]
[CH Settings]
[Tools]
[Window]
[New Window]
[Cascades]
[Tile]
[Arrange Icons]
[Close]
[Close All]
[Help]
[About 9335 Wave Processor]
Equivalent to functions on the waveform window
menu
Equivalent to functions on the
waveform window menus
[Save Waveform File]
[Logging Print Preview] (See 6.3)
[Logging Print Settings] (See 6.3)
[Logging Print] (See 6.3)
Equivalent to functions on the waveform window
menu
[Set Tools]
For recorder function, realtime function (envelope on) or rms value function
waveform data, the logging window has tabs labeled "MAX/MIN" and
"Average" at the bottom of the window. If you select the "MAX/MIN" tab,
both the maximum and minimum values are displayed. If you select
"Average" the average of the maximum and minimum values is displayed.
* Logging display may not be produced, depending on the operating
environment of your computer. In this case, narrow the display range of the
waveform window before reattempting logging display. (See 3.2.6.)
3.13 Numeric Display of Waveform Data
______________________________________________________________________________________________
3.13.2 Logging Window Toolbar
1.
2.
3.
3.13.3 Other Operations
1. Channel display setting button
Selects the channel to be displayed. Click this button to display the dialog
box, select the check box for the channel you want to display, and click OK.
2. Thin out
Sets a time interval at which intervals the numeric values are displayed.
3. Cursor search
If any referenced waveform window is referenced, you can quickly scroll
through the numeric display window until you reach the cursor A or B
positions, the interval cursor, or the search position. Click the button for the
marker for which you want to search.
Right-click in the logging window to display a popup menu.
Copy Copies a selected range of data in the logging window to the
clipboard, from where it can be pasted into "Notepad" or other applications.
To select multiple lines, hold down the
Ctrl or
Shift key while left-
clicking.
Show Waveform Shows or hides analog, pulse and logic waveforms
simultaneously.
Time Notation Changes the display method for the time shown at the leftmost
position of the window. Select from "Date", "Trigger Time", "Second", or
"Data Number".
Logging Sets a time interval at which intervals the numeric values are
displayed.
Numeric Format Changes the display method for voltage values. Select from
"Exponential", "Floating-point", or "Auxiliary unit".
Move Cursor When a reference waveform window is specified, you can move
cursors to any position in the specified waveform window. Start trigger, stop
trigger, cursor A, cursor B, section start cursor, section end cursor or search
position can be moved to a selected position in the numeric display window.
3.14 Waveform Window Hard Copy
______________________________________________________________________________________________
3.14.1 Setting Hard Copy
1.
2.
3.14.2 Executing Hard Copy
3.14 Waveform Window Hard Copy
When waveform windows are saved to a file or copied to the clipboard, you
can paste waveform images into a word processor or other applications.
Set the method for producing a screen hard copy. If you select "Capture
Settings" from the "Edit" menu, the "Capture Settings" dialog box is
displayed.
1. Set output destination
Transfer to clipboard Copies waveform images to the clipboard.
Save to file Saves waveform images to a file (always in extended meta
format).
2. Output format
Extended meta format With this format, even if you resize the image pasted
into another application, the image will not change shape significantly. If
you select this format, be sure to set an output color at the same time.
Bitmap format Images are copied in bitmap format.
Select "Capture Waveform Screen" from the "Edit" menu to execute hard
copy. If you selected "Save to file" for the output destination, the destination
setting dialog box is displayed. Enter a file name and click "Save".
4.1 Converting All
______________________________________________________________________________________________
1.
2.
3.
4.
5.
6.
Chapter 4
Text Conversion
4.1 Converting All
Once waveform data is converted into text, you can use it in spreadsheet
software such as Excel .
* Converting waveform data into text produces a file that is significantly larger
than the original file size. Make sure that the hard disk has sufficient space.
The whole of the currently displayed waveform data is converted into text.
Select "Convert All" from the "File" menu or click the convert all button on
the toolbar to display the "Convert All" dialog box. Click Save after entering
required data into the dialog box.
1. Post-conversion file name
2. File format in which to save
Select from CSV (comma separated), text (space separated), text (tab
separated), COMTRADE(1991) or NMEA 0183(GPS data). CSV format files can
be loaded in Excel .
3. Interleaved data counts
Set the number of interleaved data.
4. Time-axis format
Select from Second, Date, Trigger time, or Point.
5. Select the channels to convert
Select the channels you want to convert. The greater the number of channels
converted, the larger the resulting file size.
6. Open after conversion
Leave this check box checked to have the resulting file opened in the
application associated with it following text conversion.
4.3 Converting Collectively
______________________________________________________________________________________________
1.
2.
3.
4.
5.
6.
7.
4.2 Converting Partially
4.3 Converting Collectively
A section of the currently displayed waveform which is enclosed by section-
specifying cursors is converted into text.
Select "Convert Between Cursors" from the "File" menu or click the Convert
Between Cursors button on the toolbar to display the convert partially dialog
box. Fill out this dialog box in the same way as for converting the entire
waveform, then click Save.
If you specify "Binary" for file type, you can save a section of waveform
data enclosed by section-specifying cursors instead of converting the
waveform data into text.
By selecting and saving only a necessary part from a large waveform data
file, you can significantly reduce display time and processing time when
later analyzing that part of the waveform.
Multiple files can be converted into text collectively.
Select "Batch conversion" from the "File" menu or click the convert
collectively button on the toolbar to display the "Batch conversion" dialog
box. After filling out this dialog box, click Convert... button.
* The settings for each waveform file (files with the extension ".hps" (see 3.1)) are not
loaded.
1. File list
Select the source file you want to convert. Hold down the
Ctrl or
Shift
key while left-clicking to select multiple files.
2. File name
The selected files are displayed.
3. File type
The file format of the files is displayed in the file list.
4. Interleaving counts
5. Output destination folder
Converted files are stored in this folder. The file names in this folder are
inherited from the source files.
6. Save format
Select from CSV (comma separated), text (space separated), text (tab
separated), COMTRADE(1991) or NMEA 0183(GPS data). CSV format files can
be loaded into Excel .
7. Time-axis format
Select from Second, Date, Trigger time, or Point.
5.1 Displaying the X-Y Synthesis Window
______________________________________________________________________________________________
Chapter 5
X-Y Synthesis Window
5.1 Displaying the X-Y Synthesis Window
The waveform data can be X-Y synthesized before being displayed on the
screen. Up to 16 waveforms can be X-Y synthesized by assigning analog or
pulse channels to the X and Y axes. "MEM", "REC" (envelope off), "POW",
or "XYC" waveforms can be X-Y synthesized.
* Numerical operations cannot be performed in the X-Y synthesis window.
* Support provided only for searches by date/time. For more information on the
search method, refer to 3.7.1. Note also that trace cursor A is displayed at
the search position.
1. Load waveform data to display a waveform window beforehand. Using
section cursors, set a range of waveform you want to be X-Y synthesized.
2. Click the X-Y synthesize button on the waveform toolbar, or select "XY View"
from the "View" menu. The range of waveform enclosed by interval cursors
is X-Y synthesized. Display multiple instances of the X-Y synthesis by
repeating this procedure.
5.2 Manipulating the X-Y Synthesis Window
______________________________________________________________________________________________
5.2.1 X-Y Window Menus
[File]
[Open Waveform File]
[Edit]
[Convert All]
[Batch Conversion]
[Save Waveform File]
[Screen Print]
[Print]
[Preview]
[Page Settings]
[Waveform
Detail Print]
[Print]
[Preview]
[Page Settings]
[Printer Settings]
[Exit]
[Capture XY Screen] : Produces screen hard copy.
(See 5.5.2.)
[Capture Settings] : Sets a screen hard copy.
[View]
[Waveform View]
[Logging View]
[XY View]
[Waveform Info]
[Waveform Control] : Displays the Waveform Operations dialog box.
(See 5.5.1.)
[XY Cursor] : Displays the XY Cursor dialog box.
(See 5.3.1.)
[Toolbar]
[Settings]
[Main Toolbar]
[XY Toolbar]
[Status Bar]
[Main Status Bar]
[XY Status Bar]
[Graph Settings] : Sets XY graph display.
(See 5.2.4.)
[Compose Range Settings] : Sets a range of data to be XY synthesized. (See 5.2.5.)
[CH Settings]
[Tools]
[Window]
[New Window]
[Cascade]
[Tile]
[Arrange Icons]
[Close]
[Close All]
[Help]
[About 9335 Wave Processor]
Equivalent to the function on the
waveform window menu
Equivalent to the function on the
waveform window menu
Equivalent to the function on the
waveform window menu
Equivalent to the function on the
waveform window menu
[Search] : Displays the Search dialog box.
[Templaate] : Save or load a template file.
[Set Tools]
5.2 Manipulating the X-Y Synthesis Window
Stopping waveform drawing
For large waveform data files, the system requires more time to redraw the
waveform. To abort waveform drawing, press the
Esc
key on the keyboard.
Click the "Update" button on the toolbar to let the system redraw the
waveform window.
The main toolbar works the same way as in the waveform window. For more
information, refer to the description of the waveform window in the earlier
section of this manual.
5.2 Manipulating the X-Y Synthesis Window
______________________________________________________________________________________________
5.2.2 X-Y Waveform Toolbar
1. 2. 3.
4.
5.
6.
7.
5.2.3 Popup Menu
1.
2.
3.
5.
4.
6.
1. Cursor A operation mode
Left-click anywhere in the waveform display area when this button is
enabled to move vertical cursor A to that position. Hold down the
Shift key
and left-click to reposition the horizontal cursor A.
2. Cursor B operation mode
Left-click anywhere in the waveform display area when this button is
enabled to move vertical cursor B to that position. Hold down the
Shift key
and left-click to reposition horizontal cursor B.
3. Comment operation mode
When this button is enabled, you can enter or edit comments. Enter
comments in the same way as in the waveform window.
4. Cursor mode selection
Selects among cursor OFF, the trace cursor, and he voltage cursor.
5. Cursor display
Shows the vertical and horizontal cursors A and B.
6. Graph settings
Sets an XY synthesis window.
7. Update
Updates the waveform window.
Right-click anywhere in the X-Y synthesis window to display a popup menu.
5.2 Manipulating the X-Y Synthesis Window
______________________________________________________________________________________________
1. Gauge display
Works the same way as in the waveform window. The vertical and
horizontal axes can be set independently.
Gauge Type - Dual The gauge is displayed on both sides of the waveform
window.
2. Marker display
Cursor A, Cursor B Shows or hides the respective markers.
3. Title
Same as the title of the waveform window.
4. Inside the X-Y window
Show Waveform Shows or hides several waveforms at once.
Screen Format Up to 16 (4 x 4) graphs can be displayed.
Grid Shows or hides horizontal, horizontal auxiliary, vertical, and vertical
auxiliary lines.
Color Sets the waveform background, grid line, and auxiliary line colors.
5. Periphery of the waveform window
Synthesis Range Resets the range of waveform data to be X-Y synthesized.
Set the start and end points in the opened "XY synthesis Range Settings"
dialog box and click OK.
Show Shows or hides each display area.
Template Save or load a template file.
Capture Copies the XY screen to the clipboard or saves it to a file, from
where it can then be pasted into other applications.
Toolbar, Status bar
Shows or hides each display.
6. Waveform legend display
Channel Changes channel information display.
Show Waveform Shows or hides several waveforms at once.
Resize Changes the size (width) the waveform legend display area. The
display area is enclosed by dotted lines. Drag the left or right square at the
center of the display area to resize to the desired size.
Text Color, Font Sets the character color and font for the waveform legend.
5.2 Manipulating the X-Y Synthesis Window
______________________________________________________________________________________________
5.2.4 Setting XY Graphs
5.
1.
2.
3.
4.
6.
7.
8.
9.
10.
11.
12.13.
14. 15.
16.
Set how XY graphs are displayed.
Click the "Set graph" button on the XY window toolbar or select "Set
Graph" from the "Settings" menu to display the "Set XY Graph" dialog box.
1. OK button
The new settings are reflected in the graph. The dialog box is closed.
2. Cancel button
The new settings are canceled (i.e., not reflected in the graph). The dialog
box is closed.
3. Apply button
The new settings are reflected in the graph, but the dialog box is not closed.
4. Select graph divisions
A graph can be divided into as many as 16 regions (4 x 4).
* Depending on the window size, not all graph subdivisions may be displayed.
5. Select gauge type
Select the types of X and Y-axis voltage gauges from "None",
"Upper/Lower", "Detail", or "Multiple" respectively.
None No gauges are displayed.
Upper/Lower For channels that have gauge display turned on, the gauge for
the channel with the smallest number is displayed. Voltage values are
displayed at both ends of the gauge.
Detail For channels that have gauge display turned on, the gauge for the
channel with the smallest number is displayed. Voltage values are displayed
at every five divisions.
Multi For channels that have gauge display turned on, gauges are displayed
for as many channels as specified by gauge counts, beginning with the
channel with the smallest number. Voltage values are displayed at both ends
of the gauge.
5.2 Manipulating the X-Y Synthesis Window
______________________________________________________________________________________________
5.2.5 Setting the XY Synthesis Range
1.
2.
3.
6. Gauge counts
For multiple gauge types, set the number of gauges you want to display. For
channels that have gauge display turned on, gauges are displayed for
channels sequentially, beginning with the channel with the smallest number.
7. Gauge dual
Gauges are displayed on both sides of the graph. This item can only be set
for the Y-axis gauge.
8. Show/hide XY
Select the check box for any XY waveform to display the selected XY
waveform.
9. Waveform color setting button
Set colors for each XY waveform.
10. Select X-axis channel
Select X-axis channels.
11. Show/hide X-axis gauge
Select the check box for any channel, and the X-axis voltage gauge on that
channel is displayed. The number of gauges displayed is limited by the
gauge type and gauge counts set.
12. Select Y-axis channel
Select Y-axis channels.
13. Show/hide Y-axis gauge
Select the check box for any channel to display the Y-axis voltage gauge on
that channel. The number of gauges displayed is limited by gauge type and
gauge counts set.
14. Select interpolation method
Set the method by which the graph is interpolated. Select "Dot", "line", or
"Marker 1-8".
15. Select display graph
When the graph is divided, select the graph that shows the waveform you
want.
16. Select line width
Select the line width of the waveform.
The range of waveform data to be XY synthesized can be set.
Select "Synthesis Range Settings" from the "Settings" menu or double-click
in the "XY synthesis area" on the XY window status bar to display the "XY
Synthesis Range settings" dialog box.
1. Show synthesizable range
5.3 Cursor Function
______________________________________________________________________________________________
5.3.1 Trace Cursors
XY Cursor dialog box
1.
2.
3.
1.
3.
4.
5.
5.
6.
6.
7.
6.
6.
7.
8.
8.
8.
8.
5.3 Cursor Function
2. Set start point
Set the first point of the waveform data you want to synthesize. A relative
time for that point (time from the trigger) is displayed to the right.
3. Set end point
Set the last point of the waveform data you want to synthesize. A relative
time for that point is displayed to the right.
4. OK button
The new settings are reflected in the graph. The dialog box is closed.
5. Cancel button
The new settings are canceled (i.e., not reflected in the graph). The dialog
box is closed.
The cursor function lets you read the voltage values at specified points. Both
trace cursors and voltage cursors are available.
Shows the point at which the cursor and waveform intersect.
How to use
1. Click the cursor mode select button on the XY waveform toolbar to select
trace cursor mode.
2. Click the cursor display button on the XY waveform toolbar to display the
desired cursors.
3. Display the XY Cursor dialog box to read voltage values. Click the XY
cursor button on the main toolbar, or select "XY Cursor" from the "View"
menu.
XY Cursor dialog box
1. Time value display area
2. Time difference display area
3. Button for moving cursor
Click the up or down button to move through the data points in sequence.
5.3 Cursor Function
______________________________________________________________________________________________
5.3.2 Voltage Cursors
XY Cursor dialog box
3.
3.
4.
1.
1.
2.
1.
1.
2.
6.
6.
6.
6.
3.
3.
4.
5.
5.
5.
5.
4. Button for moving cursors A and B simultaneously
Click the up or down button to move through the data points in sequence.
5. Select graph
Select the graphs to be referenced by cursors A and B, respectively.
6. Voltage value display area
7. Voltage difference display area
8. Reference channel
Voltage values on X and Y axes can be read.
How to use
1. Click the cursor mode select button on the XY waveform toolbar to select
voltage cursor mode.
2. Click the cursor display button on the XY waveform toolbar to display the
desired cursors.
3. To move the cursor, drag the cursor marker or the cursor in the waveform
window (hold down the left mouse button while moving the cursor). Or left-
click "Cursor A operation mode" or "Cursor B operation mode" button on the
waveform toolbar and click at any position in the waveform window.
4. Display the XY Cursor dialog box to read voltage values. Click the XY
cursor button on the main toolbar, or select "XY Cursor" Window from the
"View" menu.
XY Cursor dialog box
1. Voltage value display area
2. Voltage difference display area
3. Button for moving cursor
The cursor moves in vertically or horizontally.
4. Button for moving cursors A and B simultaneously
The cursors move at the same time.
5. Select graph
Select the graphs to be referenced by cursors A and B, respectively.
6. Reference channel
5.5 Manipulating XY Graphs
______________________________________________________________________________________________
5.3.3 Popup Menu
5.5.1 Waveform Operations
Show
/hide
Change colors
5.4 Waveform Information Dialog Box
5.5 Manipulating XY Graphs
Right-click in the XY Cursor dialog box to display a popup menu.
Copy cursor value Copies the cursor values in the dialog box to the
clipboard, from where they can be pasted into "Notepad" or other
applications.
Time display Changes the display method for the time shown in the time
display area. Select from "Date", "Trigger time", "Second", or "Data Number".
Exponential, Floating-point, Auxiliary unit Changes the display format for voltage
values.
Show unit Shows or hides the unit of measure in which units the voltage
values are displayed.
The waveform information dialog box shows information on settings of each
channel.
Click the "Display waveform information window" button on the main toolbar
to bring up this dialog box, or select "Waveform Info" from the "View" menu.
The method of operation in this dialog box is the same as for the waveform
window. (See 3.6.)
You can choose to show or hide each XY graph, as well as set the waveform
color, magnifying factor, and zero position.
Click the "Display waveform operation window" on the main toolbar or select
"Waveform Control" from the "View" menu to display a "Waveform Control"
dialog box.
1. Show/hide XY graph
Select the check box for any desired XY graph.
2. Change waveform color
Left-click any desired XY graph icon to change waveform color.
5.5 Manipulating XY Graphs
______________________________________________________________________________________________
5.5.2 XY Window Hard Copy
5.5.3 Setting Scaling and Channel Comments
3. Change magnifying factor and zero position
Select the XY waveform you want to work on from the XY graph list (select
X and Y axes). The channel information assigned to the axes of the selected
XY graph is shown to the right of the list. The procedure is the same as for
the waveform window; refer to Section 3.9.1, "Waveform Operations".
* If multiple XY waveforms have the same channel assigned, operations
performed on one such XY waveforms is reflected in all other such XY
waveforms.
If XY windows are saved to a file or copied to the clipboard, you can paste
waveform images into a word processor or other applications. The procedure
used here is the same as for the waveform window; refer to Section 3.14,
"Waveform Window Hard Copy".
* If a large waveform data file is XY synthesized, waveform images may not
be pasted in extended meta format into application software.
You can set scaling and comments for each channel. Select "CH Settings"
from the "Settings" menu to display the "Channel Settings" dialog box. Use
the channel select tab in this dialog box to select the channel for which you
want to make settings. After setting scaling and comments for that channel,
click the OK or Apply button to enter your settings. The procedure used here
is the same as for the waveform window; refer to Section 3.10, "Setting
Scaling and Channel Comments".
* The scaling and channel comments are reflected in all waveform, logging,
and XY synthesis windows open for the same waveform file.
6.1 Screen Print
______________________________________________________________________________________________
6.1.1 Printing
6.1.2 Print Preview
6.1.3 Setting Screen Print
Chapter 6
Printing
6.1 Screen Print
You can print the loaded waveforms, using screen print or detail print
functions.
Prints waveform screen and X-Y synthesis screen hardcopies.
While the window for the waveform file you want to print is active, select
"Screen Print" - "Print" from the "File" menu. The print dialog box is
displayed. After setting up the printer and print range, click OK. The system
begins printing the selected screen.
* Depending on the printer being used, XY screens synthesized from large
waveform data files may not be printed.
Select "Screen Print" - "Preview" from the "File" menu to preview print
results.
Select "Screen Print" - "Page Settings" from the "File" menu to display the
"Screen Print Settings" dialog box. After setting up the printing method,
click OK.
6.2 Detail Print
______________________________________________________________________________________________
6.2.1 Printing
6.2.2 Detail Print Preview
6.2.3 Setting Detail Print
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
6.2 Detail Print
Waveforms are printed in detail.
While the window for the waveform file you want to print is active, select
"Waveform Detail Print" - "Print" from the "File" menu. The print dialog box
is displayed. After setting up the printer and print range, click Print. The
system prints the selected screen according to the current detail print
settings. To save the print image in a file, click Meta files button.
* Depending on the printer used, XY screens synthesized from large waveform
data files may not be printed.
Select "Waveform Detail Print" - "Preview" from the "File" menu to view a
print preview displayed according to the current detail print settings.
Select "Waveform Detail Print" - "Page Settings" from the "File" menu to
display the "Waveform Detail Print Settings" dialog box. Settings made in this
dialog box apply to detail prints of all waveform files.
Each item in the Set Detail Print dialog box is explained below.
6.2 Detail Print
______________________________________________________________________________________________
1. Print format
Set the format of detail print.
The formats "1 Graph" through "16 Graphs" correspond to 1-screen through
16-screen settings made when printing to the MEMORY HiCORDER's built-in
printer. The graph is divided into 1 to 16 smaller sections, and the channels set
in each of such graphs are printed. (the channel to which the graph belongs
depends on how the graph was set on the screen when divided.) In the formats
"2 rows" through "16 rows", the graph is printed on a specified number of
lines wrapping around at the end of each line. The range of waveforms (in the
time-axis direction) that can be printed in one page can be extended. But the
greater the number of rows, the smaller the number of logic waveforms
printed. (Waveforms with small position numbers have priority.)
The formats "XY1" through "XY4" correspond to the XY1 screen through XY4
screen settings entered when printing to the MEMORY HiCORDER's built-in
printer. The synthesis waveforms set in each of graphs one to four are printed.
(The correspondence of synthesis waveforms to graphs depends on how the
graph was set in the screen when divided.) "Portrait" and "Landscape" set the
print orientation.
2. Print range
Select the waveform section to print.
If you select "Display" the section currently displayed on the screen is printed.
For "All" all sections set in "Set Waveform Display Range" for the screen are
printed.
For "Selection" you can select a print range from any section, from choices
"Head", "Tail", "Cursor A", or "Cursor B". Unless both cursors A and B are
displayed, you cannot select "Selection".
3. Time-axis zoom
If you select "Same to screen" the waveform is printed with the same
magnifying factor as the graph being displayed on the screen. If the print range
does not fit onto one page, the waveform is printed on multiple pages.
If you select "Fit to page" the time-axis magnifying factor is automatically
adjusted so that the print range fits in one page.
If you select "each 1 DIV" or "each 5 DIV" in "New Page" setting, pages are
changed every 1 DIV units or every 5 DIV units, respectively. You cannot
select this setting if the time-axis magnifying factor is set to "Fit to page".
4. Specify margins, Set 1 DIV to 1 cm
If you select "Specify margins" you can specify the left, top, right, and bottom
margins in mm units. The graph is shrunk when printed, according to the set
dimensions of margins. Because the grids are adjusted to square shapes when
printing XY waveforms, margins may become larger than you set.
If you select "Set 1 DIV to 1 cm" grids are printed in 1 cm units.
* Depending on the printer used, the waveform may not fit in the printable
range, and edges may not be printed. Please note that grids can be printed in 1
cm units only with A4 or A3 paper sizes. When printing to other page sizes,
select "Specify margins" and set the margins before printing.
5. Margins
Set the Left, Top, Right, and Bottom margins in mm units.
6. Grid type
Select the type of grid from the choices "OFF", "Standard", "Detail", or "Time-
axis". (When printing XY waveforms, you can select "OFF", "Standard", or
"Detail".)
6.2 Detail Print
______________________________________________________________________________________________
7. Gauge/0 Position comment
For the type of gauge, you can select "Upper/Lower", "Detail", "0 Pos
comment", or "U/L + 0pos". If you select "Upper/Lower" only the upper/lower-
limit values on each channel are printed. Although there are many channels,
the gauges can be compact. If you select "Detail" the upper/lower limit values
and each scale value are printed. Since one gauge per channel is printed, the
greater the number of channels, the narrower the print range of the waveform.
For "0 pos comment", comments are printed in the zero position of each
channel.
For "U/L + 0 pos", both upper/lower-limit values and comments are printed.
For "Max", set the maximum number of detail gauges you want to attach to
one graph. If the graph contains more channels than set here, a set number of
detail gauges is printed in the order of channel priority, starting with the
highest. However, depending on the selected print format, the number of detail
gauges printed may be fewer than that set.
8. Channel marker
Specify how the display mode for the channel markers for the analog, pulse
and logic waveforms to be printed. Select "OFF", "CH Number", or "Comment".
If a comment character string is not set for a channel although "Comment" is
selected, "CH Number" is printed for that channel.
9. Header
Specify the information you want to include in the header. Select
"Measurement Info", "Info. + Title Comment", or "Info. + File Name".
10. Channel info.
Specify whether you want to print channel information (e.g., range and display
magnifying factor). Select "ON" or "OFF".
11. Marker Value
Specify whether you want to print measurement value at cursor A and B,
Event Marker respective positions. Select "OFF", "Cursor", "Event Marker", or
"Both".
12. Printer
Displays the set printer dialog box.
13. Preview
A print preview is displayed according to the current detail print settings.
14. Print
Displays the print dialog box to let you begin printing.
15. Advanced
Displays the set detail dialog box, allowing you to set the lines and character
fonts of graphs.
16. Default
Initialize the detailed print setting.
17. OK
Click OK to finish entering settings.
18. Cancel
The "Waveform Detail Print Settings" dialog box is closed, without saving the
changes you entered just now. (If you used Preview to preview the print image,
changes made by that point are applied. Selecting Cancel after preview will
not restore the original settings in place before the preview.)
6.2 Detail Print
______________________________________________________________________________________________
1.
2.
3.
4.
5.
6.
7.
8.
9.
Setting detail
Click the "Advanced" button in the "Waveform Detail Print Settings" dialog
box to display the "Advanced Settings" dialog box, allowing you to set the
lines and character fonts of graphs.
Each item in this dialog box is explained below.
1. Print color
Select from Color, Grayscale, or Black and white.
2. Specify part
Select the part of the graph you want to set. Set the following items for the
part selected here.
3. Line width
Set the line widths of waveforms and grids.
4. Line type
Specify how you want XY waveforms to be printed (dot, line, or marker)
and how you want the grid border, vertical line, and horizontal line to be
printed (solid or dotted line).
5. Font
Click the "Font" button to display the font dialog box. Select a font.
6. Color
Clicking the "Color" button to display the color dialog box.
Select a color.
7. Set line width and color on each channel
This setting item is displayed when you selected "Analog waveform", "Pulse
waveform", "Logic waveform", or "XY waveform" in the setting item "Item".
Select the check box labeled "Set line width and color of each CH", and set
the line width and color for each channel. If this check box is deselected, the
waveform is printed with the same line width and color as those on the
screen.
8. OK
Click OK to finish entering the settings.
9. Cancel
The dialog box is closed without saving the changes just entered.
6.3 Logging Printing
______________________________________________________________________________________________
6.3.1 Logging Printing
6.3.2 Logging print preview
6.3.3 Logging print settings
1.
2.
3.
4.
5.
7.
6.
8.
6.3 Logging Printing
While the logging window of the waveform file you want to print is active,
click [File] on the menu bar and choose [Logging Print]. The "Print" dialog
box will then appear. Complete the printer settings and click the
button. The printer will start printing using the current logging print settings.
While the logging window of the waveform file you want to preview is
active, click [File] on the menu bar, then choose [Logging Print Preview]. A
preview will be displayed according to current logging print settings.
Click [File] on the menu bar, then choose [Page Settings] to display the
"Logging Print Settings" dialog box. The settings made in this dialog box
will be applied to the logging printing of all waveform files. Parameters on
the "Logging Print Settings" dialog box are following.
1. Orientation
Set the page orientation. Choose [Portrait] or [Landscape].
2. Font
Click the button to open the "Font" dialog box. Select a printing
font.
3. Margins
Set the Left, Right, Top, and Bottom margins in units of 1 mm.
4. Printer
Display the "Set Printer" dialog box.
6.3 Logging Printing
______________________________________________________________________________________________
5. Preview
A print preview is displayed according to the current logging print settings.
6. Print
Displays the print dialog box to let you begin printing.
7. OK
Click OK to finish entering settings.
8. Cancel
The dialog box is closed, without saving the changes you entered just now.
(If you used Preview to preview the print image, changes made by that point
are applied. Selecting Cancel after preview will not restore the original
settings in place before the preview.)
6.3 Logging Printing