E16 Series Manual : Key Pages of Document

: TECHNICAL DATA

In this manual, all important information is indicated using the following symbols and conventions: : IMPORTANT TEXTS Index and Conventions Introduction to E16 series SIRIO E, CONDOR E transmitting unit Warnings for use Warnings for maintenance Operation of SIRIO E, CONDOR E transmitting unit Frequencies Settings SIRIO E, CONDOR E transmitting unit diagnostic ! abcd. . . abcd. . . abcd. . . abcd. . . Page 1 Before installing, starting and using the radio remote control, this manual MUST be read and understood carefully by all people who instal ...

INTRODUCTION TO E16 SERIES

Each E16 series radio remote control is in conformity with the R&TTE 99/05/CE Directive and all its essential requisites. Each radio remote control is also in conformity with the norms given in the EC conformity declaration present in this manual. Page 2 ! PERMITTED USES: Material lifting machines (construction cranes, industrial bridge cranes, concrete pumps, machines for moving material in general, . . . ) Industrial radio remote controls of the E16 series are used to command machines from a distance. Each industrial radio remote control is made up of a portable transmitting unit, from wh ...

!In any cases

of emergencies, faults or damaged parts, ALWAYS stop the “machine + radio remote control” system until the problem has been solved. ! Any damaged parts can ONLY be replaced by authorised Autec personnel, and only using original Autec spare parts. ENGLISH LIMITATIONS & AUTHORISATIONS It should be remembered that in some countries must be respected rules which control: - the use and/or possession of a radio remote control; - the use of operational frequencies which have not yet been harmonised in Europe. ! All the indications that must be observed can be found in the "Limitations & Autho- risations" document, which is included in ...

E16 SERIES TECHNICAL DATA

433.050 ÷434.790 MHz (or 869.7 ÷870 MHz) 32 at 433 MHz (or 12 at 870 MHz) 25kHz ��8 <10 exp-11 100 m -20°C÷+70°C <100 ms <100 ms 1 second (optional 0,5 s) Frequency range Programmable radio channel Channel spacing Hamming distance Probability of non-recognition of error Typical working range Working temperature Time of reply to commands Time of reply to STOP Passive emergency time LIE16MU1 ...

SIRIO E, CONDOR E TRANSMITTING UNIT

A SIRIO E, CONDOR E transmitting unit can be used with one of the following receiving units: This manual refers exclusively to the transmitting unit: the installation warnings are given in the receiving unit manual. - Type E16URX - Type E16URQ. Page 5 The E16 series is equipped with a safety function called SAFETY which protects the "radio remote control + machine" system from involuntary movements caused by possible radio remote control faults. A starting keyswitch E STOP button B green signalling LED F identification plate C actuators (joystick and selector) G START pushbutton D technical ...

green signalling LED

F identification plate C actuators (joystick and selector) G START selector D technical data plate H battery NiCd 7,2V - 0,7 Ah or NiMH 7,2V - 1.3 Ah internal < 10 mW ERP < 5 mW ERP nylon (20% fg) IP65 263x160x173 mm 1,4 kg ~ 15 hours ~ 7 minutes SIRIO E, CONDOR E TRANSMITTING UNIT TECHNICAL DATA Power supply (battery pack) Antenna Transmitting power (frequency 433 MHz) Transmitting power (frequency 870 MHz) Housing Minimum protection grade Dimensions Weight Autonomy with fully charged battery (at 20°C) Warning of low battery charge Page 6 LIE16MU1 ...

WARNINGS FOR USE

! ! ! ! ! ! ! ! ! NEVER LEAVE the transmitting unit unguarded when the starting keyswitch is inserted Page 7 BE POSITIONED in a way that permits him to see the “machine + radio remote control” system, and above all the load, in the best possible way. VISUALLY FOLLOW all movements of the machine and its load remaining inside a typical range of action of the machine PAY ATTENTION to the entire work area. Press the STOP button in case of hazard ONLY SWITCH ON OR USE the transmitter unit when starting work: improper use could be hazardous SWITCH OFF the transmitter unit when work is interrupted. Avoid leaving the load suspended in t ...

No particular maintenance needs to be carried out on the transmitting unit, but the

following should be done in order to always keep it reliable and safe: 1) always store the unit in a clean dry place, 2) remove dust or accumulations of other material from the transmitting unit (never use solvents or flammable and corrosive products), 3) make sure that the gaskets, bellows and the actuator hoods (joystick, selectors and pushbuttons) are whole, soft and elastic, and that the symbols on the panel can be seen clearly 4) make sure that the battery seat is always clean 5) make sure that the battery contacts are clean 6) check for signs of dama ...

To switch on the transmitting

unit, insert the starting key and turn it to "I". To start the radio remote control functions, press the “START” (or activate the selector) button or selector for 1÷2 seconds. After starting, the green signalling LED always lights up. OPERATION OF SIRIO E, CONDOR E TRANSMITTING UNIT Page 9 LED SIGNALS POWER AND STARTING STOPPING To stop the machine immediately, press the STOP button. To start working again, turn the STOP button in the direction indicated to deactivate it and repeat the power o n a n d s t a r t i n g procedure. ! The STOP button should be used when it is necessary to stop the machine immediately i ...

To recharge a flat battery, proceed as

follows: 1. Insert the battery into its proper battery charger, which should be positioned in an area having a temperature of between +5°C and +35°C. The battery now starts charging, a state signalled by the lighting up of the “ON CHARGING” pilot light. After a maximum of 4÷5 hours the "END OF CHARGE" indicator switches off: the battery is fully charged. Remove the battery from the charger (if the battery is not removed, charging continues in maintenance mode). 2. CHARGING THE BATTERY The transmitting unit should be switched off each time work is stopped by turning the ignition key to "O" and extracting ...

Within 4 seconds after the

STOP button has been pressed, press the START pushbutton (or the selector) then release it. 1 2 3 Page 11 FREQUENCIES With the transmitter unit ON (flashing green LED), press the STOP button. Working frequency change process Turn the STOP button in the direction indicated and repeat the power on and starting procedure. WORKING FREQUENCIES AUTOMATIC SCANNING MODE The radio remote control is usually programmed by the manufacturer in this mode: it can therefore work in any of the available frequencies. In cases of interference or conflict with other systems, this mode makes it possible to move the working frequency (see the ...

OFF OFF OFF OFF OFF ON

433.075 433.975 OFF OFF OFF ON ON ON 434.000 433.100 ON OFF ON OFF OFF OFF ON ON OFF OFF OFF OFF ON OFF ON OFF OFF OFF ON ON OFF OFF ON ON ON ON ON OFF OFF ON ON 434.050 434.075 434.175 434.200 433.150 433.300 433.275 433.175 ON ON OFF OFF ON OFF ON OFF OFF ON OFF OFF ON ON OFF ON OFF OFF DIP SWITCH DIP SWITCH MHz MHz ON ON OFF OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF 434.250 434.275 434.425 433.350 433.525 433.375 ON ON OFF OFF ON ON ON OFF OFF ON OFF OFF ON ON OFF ON ON ON ON ON OFF OFF ON ON ON ON OFF OFF ON ON 433.550 433.650 433.750 433.725 433.675 433.850 433.875 434.550 434.450 434.750 ...

TRANSMITTING UNIT DIAGNOSTIC

If the “machine+radio remote control” system does not start, check if the problem is caused by the radio remote control or the machine. Before carrying out any verifications, check the functioning of the machine with the cable control panel: - if it does not switch on, the problem lies with the machine itself - if it does switch on, the problem lies with the radio remote control. In this case, proceed as follows: ENGLISH Is the led on with a steady light? Is the STOP button or one of the movement actuator inserted? Release it/them The battery is discharged: replace it with one that is charged. Does i ...

Remote Control PDF Instructions

GRC-151
Kenwood GRC-151
29.04.2026 2 pages

GRC-150/GRC-151 GRAPHICAL REMOTE CONTROL UNIT INSTRUCTION MANUAL Thank you for purchasing the Graphical Remote Control Unit. Read the instructions carefully before use so that you can use the unit correctly. BOÎTIER DE TÉLÉCOMMANDE GRAPHIQUE MODE D’EMPLOI User and installation guide for the Kenwood GRC-151 Remote Control. This manual explains configuration options, security instructions, operation.

RC-1216H
Microbit RC-1216H
26.04.2026 79 pages

USER MANUAL m crob t RC-1216H Ba-RC1216H-PA9  Microbit 2.0 AB 2010. All rights reserved a User manual Rev. PA9 – 2014 Sept 10 1 of 79 RC-1216H Web based remote control for SteppIR, ACOM-2000A, Expert 1K-FA, Elecraft KPA500 and Rotators User Manual Device maintenance guide for the Microbit RC-1216H Remote Control. It provides information on safety and energy usage, component overview, installation procedures, user settings.

VSE KLR 100
Velux VSE KLR 100
08.08.2026 3 pages

VAS 452416-0309 VSE/VCE KLR 100 ENGLISH: Quick start guide ESPAÑOL: Guía rápida FRANÇAIS : Guide de démarrage rapide Step-by-step user manual for the Velux VSE KLR 100 Remote Control. This manual elaborates on component replacement, safety features, shutdown procedures, supported accessories.

MRX-70
Yamaha MRX-70
20.03.2026 14 pages

Practical operating guide for the Yamaha MRX-70 Remote Control. This manual covers installation, operation, and installation support, firmware installation, technical specifications, service procedures.