Flowserve Valtek MaxFlo 3 Installation Operation & Maintenance

Text of Flowserve Valtek MaxFlo 3 Installation Operation & Maintenance

User instructions - MaxFlo 3 - VLENIM0052-02 02.07

1 Valtek MaxFlo 3 Control Valves Installation Operation Maintenance USER INSTRUCTIONS

User instructions - MaxFlo 3 - VLENIM0052-02 02.07

2 1 GENERAL INFORMATION 1.1 Use The following instructions are designed to assist in the unpacking, installation, and maintenance as required for Flowserve products. Product users and maintenance personnel should thoroughly review this manual prior to installing, operating, or performing any maintenance. In most cases, Flowserve accessories, actuators and valves are designed for specific applications (

User instructions - MaxFlo 3 - VLENIM0052-02 02.07

3 STOP! WARNING: Before products are returned to Flowserve for repair or service, Flowserve must be provided with a certificate that confirms that the product has been decon- taminated and is clean. Flowserve will not accept deliver- ies if a certificate has not been provided (a form can be obtained from Flowserve). 1.8 Storage In most cases, Flowserve products are manufactured from stainless steel. Pr

User instructions - MaxFlo 3 - VLENIM0052-02 02.07

4 Table I: Line Flange Bolting Specifications 4 QUICK-CHECK Before commissioning, check the control valve by fol- lowing these steps: 4.1 Check for full stroke by varying the instrument signal settings appropriately. Observe the plug position in- dicator located on the actuator or the positioner. The plug should change position with a smooth turning movement. 4.2 Check all air connections for leaks.

User instructions - MaxFlo 3 - VLENIM0052-02 02.07

5                          Item 117 Packing box nuts Item 109 Packing box studs Item 80 Gland flange Item 87 Packing follower Item 114 Bonnet nuts Item 108 Bonnet studs Item 93 Packing spacer Item 88 Packing set Item 99 Packing stop Item 40 Bonnet Item 42 Purge plug (optional) Item

User instructions - MaxFlo 3 - VLENIM0052-02 02.07

6 6 VALVE DISASSEMBLY WARNING: To carry out this operation, it is essential to disconnect the valve from the pipework. Depressurize line to atmospheric pressure and drain all fluids before working on the valve. Failure to do so can cause serious injury. Remove the valve from the pipeline. Refer to figure 1 to find parts according to the item num- bers. 6.1 Remove the actuator from the body by separati

User instructions - MaxFlo 3 - VLENIM0052-02 02.07

7 7.10 Place the bonnet gasket (item 58) on the gasket step in- side the body. Gently push the bonnet into the bonnet bore. NOTE: When installing the bonnet, orient the milled faces on the bonnet perpendicular to the flanges of the valve body. 7.11 Place the packing stop (item 99) into the bonnet, then in- stall the packing spacer (item 93) and packing as shown in figure 3. 7.12 Install bonnet nuts an

User instructions - MaxFlo 3 - VLENIM0052-02 02.07

8 8 SEAT REPLACEMENT WARNING: The actuator must be removed from the valve body prior to replacing the seat ring. 8.1 To replace the seat, see figures 4 and 5, and proceed as follows: 8.2 Loosen the packing box nuts. 8.3 Using the appropriate retainer tool (see Table III), re- move the seat retainer. (Retainer tools are available from the factory). 8.4 Remove the seat and any shims that may be install

Flowserve Control Unit Owners Instructions: