Flowserve Valtek CavControl Trim Installation, Operation & Maintenance Instructions
Text of Flowserve Valtek CavControl Trim Installation, Operation & Maintenance Instructions
Valtek No. 10003460
15-1
Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611
Valtek CavControl Trim
GENERAL INFORMATION
The following instructions are designed to assist in
assembling, disassembling and troubleshooting
Valtek® globe valves equipped with CavControl™ trim.
Product users should thoroughly review this bulletin in
conjunctio
Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611
3. If the pressure-balanced sleeve binds with the plug,
carefully lift the sleeve out with the actuator/plug
assembly. Place several sturdy, soft supports (pref-
erably wood) underneath the sleeve after it clears
the body. Lower the actuator/plug assembly until
the sleeve and the supp
Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611
15-3
4. Retract plug to the full-open position by applying air
to the lower cylinder port.
5. Lower the actuator/plug assembly squarely into
the valve body.
CAUTION: Lower plug squarely into sleeve to
prevent galling and scoring of trim parts. Plug
seals must be compressed, using an approp
© 2000 Flowserve Corporation. Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611
FCD VLAIM015-07
Troubleshooting Chart
Failure
Probable Cause
Corrective Action
Jerky stem
1. Overtightened graphite packing
1. Graphite packing is often associated with jerky
movement
stem movement
2. Galling or scoring between plug
2. Superficial scoring or