GEIGER GFU004 Operating Instructions Manual
Text of the manual
Gerhard Geiger GmbH & Co. KG | 100W0652
0221
en
EN
1. General
The GFU004 is a Venetian blind control for flush-mounted installation. It has connections for two
external push-buttons, for the tubular motor and for the mains connection. The operation and the
control installation are effected via operating button, radio transmitter, sun/ wind / rain / service
2.1 Learning a transmitter
The order sequence is specified: the first input on a transmit button receives the function UP, the
second input the function DOWN.
1. Hold the transmitter to be learned directly to the receiving antenna and press a key about
3 seconds until an audible signal is emitted. The learning mode is activated.
2. Keep ho
Gerhard Geiger GmbH & Co. KG | 100W0652
0221
en
EN
• Upon reception of the sensor command „rain“, a retract command is triggered and a certain
pre-programmed disable time starts running. During the disable time, both the „sun“ and the
„twilight“ sensor are disabled. Operation in manual mode is nevertheless possible via the
hand-held transmit
5. Declaration of Conformity
The Declaration of Conformity concerning this product is available on our website: www.geiger.de.
6. Connection Diagram
These buttons must be potential-free. Please do not use here 230 V. This would damage the control.
7. Waste Disposal
Recycling of packaging materials
In the interest of environmental protectio
Gerhard Geiger GmbH & Co. KG | 100W0652
0221
en
EN
For technical questions, please call our service team at: +49 (0) 7142 938 333.
They will be happy to assist you.
Gerhard Geiger GmbH & Co. KG
Schleifmühle 6 | D-74321 Bietigheim-Bissingen
T +49 (0) 7142 9380 | F +49 (0) 7142 938 230
[email protected] | www.geiger.de