Securitron Magnalock Corp.

www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions © Copyright, 2011, all rights reserved PN# 500-22115 Page 1 Rev. C, 05/11 CONCEALED ELECTRICAL POWER TRANSFER SERIES CEPT INSTALLATION INSTRUCTIONS PRODUCT COMPATIBILITY NOTE: The Securitron CEPT will NOT operate properly on openings with the following door/frame/hinge configurations:  Offset Pivots  Pocket Pivots  Center Hung Doors  Butt Hinges over 6”  Swing Clear Hinges  Balanced Doors Available CEPT Models: CEPT-10 Traditional Connect 10 Wire (2 + 8) (2) Wire Nut + (8) Crimp EL-CEPT ElectroLynx® (Assa Abloy) 12 Wire (8 + 4) Connectors: 8 Pin + 4 Pin CEPT-C5E CAT 5e (TIA/EIA-568-B Compatible) 9 Wire (8 + 1) Connectors: 6 Pin + 4 Pin DESCRIPTION The Concealed Electrical Power Transfer CEPT unit is designed to provide a secure multiple wire power and/or data transfer between a door frame and door. The unit mounts directly between the frame and door along the hinged edge and is available in three multi-wire configurations. The CEPT is non-handed, allows mechanical (hinged) movement of the door and is totally concealed when the door is fully closed. This manual provides the information required to successfully install a CEPT to a standard hinged door opening. www.TMHardware.com Page #1 Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions © C h 20 ll h d 00 22 CONCEALED ELECTRICAL POWER TRANSFER SERIES CEPT INSTALLATION INSTRUCTIONS PRODUCT COMPATIBILITY NOTE: The Securitron CEPT will NOT operate properly on openings with the following door/frame/hinge configurations:  Offset Pivots  Pocket Pivots  Center Hung Doors  Butt Hinges over 6”  Swing Clear Hinges  Balanced Doors Available CEPT Models: CEPT-10 Traditional Connect 10 Wire (2 + 8) (2) Wire Nut + (8) Crimp EL-CEPT ElectroLynx® (Assa Abloy) 12 Wire (8 + 4) Connectors: 8 Pin + 4 Pin CEPT-C5E CAT 5e (TIA/EIA-568-B Compatible) 9 Wire (8 + 1) Connectors: 6 Pin + 4 Pin DESCRIPTION The Concealed Electrical Power Transfer CEPT unit is designed to provide a secure multiple wire power and/or data transfer between a door frame and door. The unit mounts directly between the frame and door along the hinged edge and is available in three multi-wire configurations. The CEPT is non-handed, allows mechanical (hinged) movement of the door and is totally concealed when the door is fully closed. This manual provides the information required to successfully install a CEPT to a standard hinged door opening. www.TMHardware.com CONCEALED ELECTRICAL POWER TRANSFER UNIT INSTALLATION INSTRUCTIONS Model Supplied is EL-CEPT

Components included with this Product:

Item Description Quantity A CEPT Assembly 1 B Back Box 2 C Screws, 10-24 x 3/4” Phillips Flat Head Undercut (for metal) 13 D Screws, #10 x 3/4” Phillips Flat Head (for wood) 13 E Strain Relief Bushing 2 F Wire Nut (CEPT-10 Only) 4 G Dolphin™ Connector (CEPT-10 Only) 17 RECOMMENDED TOOLS Basic for Factory Prepped Door Install: Additional for More Detailed Install:  Hammer  Flat Tip Screwdriver: 1/4”  Phillips Screwdriver: #2  Wire Strippers/Crimpers  Pliers  Center Punch  Drill Motor & Bits  Reciprocating Saw & Blades  Router & Bits  Chisel  Metal File SPECIFICATIONS Physical For proper installation and operation of the CEPT, the thickness of the door should be 1-3/4” minimum. The door opening limitations listed here apply to a (1-3/4”) door equipped with the following hinge sizes and configurations. Door Hinge Configuration: Door Opening Angle Range: Up to 5” Butt Hinge 0-180° 5-1/2” Butt Hinge 0-130° 6” Butt Hinge 0-110° A B C D G E F www.TMHardware.com Page #2

The following chart shows the electrical specifications for each CEPT model.

MODEL TYPE WIRE SIZE/QTY CURRENT LIMIT (Per Wire) 18 AWG/2 Max. 5A CEPT-10 10 Wire (2+8) 22 AWG/8 Max. 1A EL-CEPT ElectroLynx® (8+4) 22 AWG/12 Max. 1A 24 AWG/8 Max. 1A CEPT-C5E CAT 5e (8+1) 22 AWG/1 Ground (Max. 1A) INSTALLATION INSTRUCTIONS NOTE: The CEPT should always be mounted above the second hinge from the floor. The CEPT was designed primarily to be installed into a factory prepped door and frame. However, the unit can be installed into an un-prepped door and frame by following the specific instructions provided on the product installation diagram. The following exploded illustration shows the included hardware required to properly install a CEPT to a factory prepped door opening (CEPT-10 shown). To install the CEPT to a factory prepped door and frame:  Route/pull utility wires/cable through the prepped holes in door and frame.  Pop out the desired knock-out hole in the back box. Notes: 1. Back boxes are normally required to meet fire code requirements. 2. The 7/8” diameter knock-out holes in the back boxes are provided for EMT type electrical conduit fittings. 3. The 5/8” diameter knock-out holes are for use of the provided strain relief bushings.  To install the strain relief bushing, lay the utility cable (not included) into the slotted opening in the bushing allowing a sufficient wire length (loop) for making connections. Fold the hinged retainer over the cable, squeeze together using pliers and then insert through the 5/8” [15.9mm] knock-out in the back box. (Prepped) Door (Prepped) Frame Back Box(es) CEPT www.TMHardware.com Page #3

When required, install the appropriate connectors for ElectroLynx® or CAT 5e (not

included) to the end of your utility cable.  Using a #2 Phillips screwdriver, attach each back box to the door and/or frame using the 10-24 x 3/4” long screws (for metal) or the #10 x 3/4” long screws (for wood). These screws are to be placed through the center hole in each flange of the back box. Metal Door Prep. Wood Door Prep.  Make connections to the CEPT by: o Using the connectors (EL-CEPT or CEPT-C5E models). o Using the provided wire nuts for connection of the two (2) 18 AWG wires - and by using the Dolphin™ (crimp type) connectors to make the appropriate connections to the remaining 22 AWG wires (CEPT-10 model).  Using a #2 Phillips screwdriver, assemble each side of the CEPT to the door and frame using the 10-24 x 3/4” long screws (for metal) or the #10 x 3/4” long screws (for wood). These screws are to be placed through the four corner holes in the face flange of each of the CEPT housings and also through the outer (clearance) holes in the back box. MAGNACARE LIFETIME REPLACEMENT WARRANTY For warranty information visit www.securitron.com/en/site/securitron/About/MagnaCare-Warranty/ Back Box Back Box CEPT 10-24 X 3/4” CEPT #10 X 3/4” www.TMHardware.com Page #4

PROVIDE STEEL BACKING TAB (2 REQUIRED)

.105" THICK (12 GAUGE) RECOMMENDED - .060" THICK (16 GAUGE) MINIMUM 1 4" 1" COUNTERBORE RACEWAY 1/4" DEEP (TYP.) THRU TO " 1 4 (TYP.) " " 7 4 3 5 1 8 " 64 43 " 5 8 11 16" B A A B CL ) AT OPPOSITE END OF CAVITY AS THAT HOLE DRILLED IN DOOR MUST BE OF FRAME (AS SHOWN; A-A OR B-B) : IF HOLES ARE REQUIRED 500-20295 Rev. D CL DOOR FRAME CEPT INSTALLATION DIAGRAM NOTE: THIS DRAWING IS NOT TO SCALE! DOOR (OPEN 180 THE CEPT SHOULD BE MOUNTED 6" ABOVE THE SECOND HINGE FROM THE FLOOR (40" MINIMUM) 1 3 " 1 " 4 1 " 1 4 3 " 8 8 " 9 32 3 8 (MIN.) 6" CORNERS SQUARE METAL: FILE ALL WOOD: CHISEL ALL CORNERS SQUARE CL OF DOOR CUTOUT 3 8" .150") AND 3 " 4 TAP ALL HOLES 10-24 METAL: DRILL #25 ( THRU 5/32" X 3/4" DEEP WOOD: DRILL ALL HOLES 5 8" MUST ALIGN WHEN DOOR CENTERLINE OF CUTOUTS .88 IS CLOSED THICKNESS THIS VARIABLE DIMENSION IS DEPENDENT ON DOOR Page #5 www.TMHardware.com