Key Pages of Document

Establishing basic functionality ............................................................................................ 5

2 TCS3400 EVM graphical user interface (GUI) ..................................................................... 6 2.1 Software overview ........................................................................ ...

The TCS3400 device provides color and IR (red, green, blue, clear and IR) light sensing. The color

sensing provides for improved accuracy lux and color temperature measurements typically used to adjust the backlight intensity and correct the display color gamut. Additionally it can be used for light source type detection as it reports the I ...

When the USB cable is connected, the green LED should flash indicating that power is being

received via the USB interface, and the controller board processor is running. If the green LED does not flash, check the USB cable connections; unplug the USB cable and try again. If the green LED still does not flash, check the PC for USB error messages. Se ...

Establishing basic functionality

The software should be started selecting ams->TCS3400 EVM->DigitalLightSensor in the App Programs menu or by double clicking the DigitalLightSensor.exe file from the installation directory. The default installation directory, depending on the operating system you are using, is: C:\Program Files\ams\TCS3400EVM Wind ...

the ams website, www.ams.com, there should be enough information to allow evaluation of the

TCS3400 device. 2 TCS3400 EVM graphical user interface (GUI) 2.1 Software overview On initialization the software displays two windows – a smaller “Digital Light Sensor” window and a larger window containing controls pertinent to the device connected. ...

This window has inputs organized on the left, and outputs organized on the right. Values for register

variables may be set using multiple techniques. The Functional tab is commonly used to quickly evaluate the device with nominal settings. The Input Register tab allows the register settings to be changed, and the Output Register tab allows register ...

6. Log – Creates a comma-separated values file containing the log data. The name will be

assigned as explained in #3. This will cause the system to write out any data currently in the log buffer. 7. Count of samples in the log buffer. When that number reaches the limit selected in #9, the system will show a file dialog to save the log in a named ...

When the software initializes, a default wait period of 2.7mS is inserted between the ALS

executions. This duration can be adjusted in 2.7mS steps from 0 to 691mS. Note that, if the WEN control bit is not turned on, the device will not insert the wait period. The WLONG bit, when enabled, causes the displayed wait time to be multiplied by ...

“ALS” Sub Tab

The ALS tab shows the registers associated with ambient light sensing control. Register values in hex are shown on the left, preselected values are available in list boxes in the middle, and actual values are shown on the right. • ATIME Register (0x81) controls the ALS integration time. The actual time is: (256-ATIME) * 2.7 mS ...