Draper Artisan E Series Installation And Operating Instructions

Specifications

Brand: Draper
Category: Projection Screen
Model: Artisan E Series (Installation And Operating Instructions)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the Draper Artisan E Series Installation And Operating Instructions online using the built-in PDF viewer.

Text of the manual

Copyright © 2002 Draper, Inc.

Form ArtisanEV_Inst02 Printed in U.S.A. Installation/Operating Instructions Artisan/Series E & V Electric Projection Screen by Draper Caution ➀ Read instructions through completely before proceeding. ➁ Follow instructions carefully. Installation contrary to instructions invalidates warranty. ➂ Screen should be accessible for complete removal should fabric become damaged or should other service be required. ➃ Screen should be installed level (using a carpenter’s level). ➄ Nothing should be fastened to screen dowel or viewing surface. ➅ Operating switch(es) packed separately in screen carton. Do not discard with packing material. ➆ Screen operates on 110-120v, 60 Hz. current. NOTE: Screen has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment. Hanging Screen General: When locating viewing surface and checking clearance for screen’s operation, remember surface is centered in case. Take care to install wall/ceiling electrical box and conduit so they will be fully concealed by the screen case after installation. The Artisan’s furniture-quality case should always be handled carefully to avoid scratching and protect its finish. Regardless of mounting method, screen should be positively and securely supported so that vibration or even abusive pulling on the viewing surface will not cause case to work loose or fall. Installer must insure that fasteners used are of adequate strength and suitable for the mounting surface chosen. Wall Installation: Mount 2, 3, or 4 aluminum brackets provided on the wall at desired height, using toggle bolts provided or other appropriate fasteners. Verify that they are in line and level to fully engage matching brackets pre-installed on back of screen case. When screen is set on brackets, pull down gently to ensure that it is snug and secure. Ceiling Installation: Install through the two 5/16" diameter mounting holes at each end of the screen case, using appropriate fasteners. Electrical Connections Screen operates on 110-120v, 60 Hz. current. Junction box is located in the left end of case. It is accessible through bottom of case when hinged door is opened. Junction box contains red, black and white pigtail leads and green internal ground wire, per wiring diagram on reverse. Wall or ceiling electrical box should be installed so as to be fully concealed by screen case after installation. Conduit openings are covered by plastic caps Operation Before operating screen remove tape securing fabric and dowel to roller. If viewing surface hangs out of case 8" or 9", tape has probably been broken by rough handling in shipment, allowing surface to “unwrap” one turn about the roller. Manually wrap fabric back around the roller without turning the roller itself. 110-120v Single Station Control — 3-position up-off-down switch permits operation to be stopped at any point. Factory adjusted limit switches automatically stop screen when fully down or fully up. 110-120v Multiple Station Control—Switches are similar in appearance to 110-120v Single Station Control. Screen stops when switch is released and may be restarted in either direction. Factory adjusted limit switches stop screen automatically when fully up or fully down. 24v Control — Three-button up-stop-down switches stop at any point desired, operate in any sequence. Factory adjusted limit switches automatically stop screen when fully up or fully down. Key Operated Switching — Two kinds of key-operated switches are optionally available with this unit. ➀ The key-operated power supply switch controls power to the screen and switches. When it is “off”, the switches will not operate screen. Key may be removed from the switch in either “on” or “off” position. ➁ A three-position key switch permits the screen to be operated directly by key. In this case, the screen’s operator must always have a key. Adjustments Screen has been factory set and should not normally require further adjustment. However, if you desire to change the “up” and “down” stopping positions, proceed as follows: CAUTION: Be sure all switches are in “off” position before adjusting limit switches. Always be prepared to shut screen off manually when new adjustment is being tested. Screen may be severely damaged if viewing surface is allowed to run too far up or too far down. Adjusting “fully up” position — “Up” stopping position may be adjusted by turning the yellow limit switch adjustment socket. The yellow socket is located on left end of screen roller and is accessible to a screwdriver/Allen wrench (4mm or 5/32"). Turning the socket counterclockwise will allow the viewing surface to retract farther into the case. Turning it clockwise will cause the surface to stop farther out of the case. One full revolution of the socket will alter the stopping position of the viewing surface by approximately 1½". Adjusting “fully down” position — “Down” stopping position may be adjusted by turning the white limit switch adjustment socket. The white socket is located on the left end of screen roller and is accessible to a screwdriver/ Allen wrench (4mm or 5/32"). Turning the socket counterclockwise will allow the viewing surface to run farther down. Turning it clockwise will shorten the viewing surface, causing it to stop in a less extended position. At no time should viewing surface be unrolled enough to expose any part of screen roller. If you encounter any difficulties installing or servicing your Artisan screen, call your dealer or Draper, Inc., Spiceland, Indiana, (765) 987-7999, fax (765) 987-7142, or e-mail [email protected]. Z-brackets supplied with screen for wall mounting. Hardware by others. Z-brackets on rear of case Screen Case Knockout for rear conduit connection Left end 5/16" holes for ceiling mounting. 2 each end. Wall Knockout for top conduit connection (to be removed for installation). Opening for ceiling mounting is located in top, 27/8" from the end and 2½" from the back of the case. Opening for wall mounting is in back, 27/8" from the end and 2¾" from the top of the case. Screen is shipped with internal wiring complete and control switch(es) fully boxed. Wire connecting screen to switch(es) and switch(es) to power supply should be furnished by installer. Connections should be made in accordance with attached wiring diagram, and wiring should comply with National and local electrical codes. All operating switches should be “off” before power is connected. Please Note: Instructions for adjusting Draper’s Tab-Tension System for Series/V screens are on page 2.

Fabric width + C

D B A Wiring Diagrams Series E 5" 5¼" 12" 6" A B* C D *Add 11/8" to height if case is to be bevel style. Tab-Tension Adjustment Procedure Dowel Adjustment Screw Tensioning Cable Draper’s Tab-Tensioning System is factory-set, and under normal circumstances will not require field adjustment. If, however, you notice wrinkles, waves, or other indications that the tensioning cables need to be adjusted, follow the procedure below. ➀ Determine which side requires adjustment. ➁ Secure dowel with one hand. Caution: Do not touch or bend surface. ➂ Using Philips-head screwdriver, depress spring-loaded adjustment screw and slowly turn clockwise to tighten tension, or counterclockwise to loosen tension. The screw adjusts in ¼ turn increments. Adjust only one increment (¼ turn) at a time. ➃ If problem is not corrected, leave screen in position for 24 hours to allow surface material to stretch into position. ➄ If problem still is not corrected, repeat steps 2 and 3. Artisan Projection Screen by Draper Page 2 of 2 Series V 6" 63/8" varies varies STOP Single Station Control Internal Screen Wiring White (Common) Black (Down) Red (Up) Green (Ground) Dashed wiring by electrician Control switch Single gang box by others Min. 4" x 2 1/8" x 1 7/8" deep Blue Black Red Location of key operated on-off switch if furnished To 110-120V Line Multiple Station Control Internal Screen Wiring White (Common) Black (Down) Red (Up) Green (Ground) Dashed wiring by electrician Red Red Black Blue Blue Cap off with wire nut and tape Black Red Blue Black Single gang box by others Min. 4" x 2 1/8" x 1 7/8" deep. 3 shown. More or less equally feasible. Location of key operated on-off switch if furnished To 110-120V Line Low Voltage (& Wireless) Control Wiring Diagram Control Switches 24v DC Black (DN) Red (UP) White (COM) Black (DN) Red (UP) White (COM) Black (DN) Red (UP) White (COM) STOP Black Red White White Red Brown Black Yellow Green Low Voltage Control Module Internal Screen Wiring White (Common) Red (Up) Black (Down) Green (Ground) Dashed wiring by electrician Optional Infrared Receiver Package Optional Radio Receiver Package Location of key operated on-off switch if furnished To 110-120V Line

Other Projection Screen Manuals