Transponder-Coded Safety Switch With Guard Locking
CTP-AR Unicode/Multicode
Transponder-Coded Safety Switch CTP-AR
2
(translation of the original operating instructions) 2123041-08-01/21
Contents
1.
About this document ............................................................................................. 4
1.1.
Scope ............................................................................................................................................4
1.2.
Target group ...........................
EUCHNER CTP-AR Unicode 2123041-08-01/21 (translation of the original operating instructions)
Operating Instructions
Transponder-Coded Safety Switch CTP-AR
EN
10.5.
Maximum cable lengths .................................................................................................................19
10.5.1.
Determining cable lengths using the example table ..........................................................20
10.6.
Connector assignment of safety switch CTP-…-AR-…-S
Transponder-Coded Safety Switch CTP-AR 4
(translation of the original operating instructions) 2123041-08-01/21
1. About this document
1.1.
Scope
These operating instructions are valid for all CTP-L.-AR… from version V1.0.0. These operating instructions, the document
Safety information and any enclosed data sheet form the complete user information for your device.
1.2.
Target group
Design engineers and installation planners for safe
2123041-08-01/21 (translation of the original operating instructions) Operating Instructions
Transponder-Coded Safety Switch CTP-AR
EN
2. Correct use
Safety switches series CTP-L.-… are interlocking devices with guard locking solenoid (type 4). Devices with unicode evaluation
possess a high coding level, devices with multicode evaluation possess a low coding level.
In combination with a movable guard and the machine control, this safety component prev
Transponder-Coded Safety Switch CTP-AR 6
(translation of the original operating instructions) 2123041-08-01/21
NOTICE
For information about combination with an AR evaluation unit, please refer to chapter 10.10. Connection
of several CTP‑AR in a switch chain on page 24.
3. Description of the safety function
Devices from this series feature the following safety functions:
Monitoring of guard locking and the position of the guard
(int
2123041-08-01/21 (translation of the original operating instructions) Operating Instructions
Transponder-Coded Safety Switch CTP-AR
EN
Control of guard locking
If the device is used as guard locking for personnel protection, the control of the guard locking must be regarded as a
safety function.
The device does not feature a safety characteristic for the control of the guard locking, because the guard locking solenoid
is completely disconnected from outs