CommScope BUDI-M-TH Installation Instruction
File Specifications
| Brand: | CommScope |
| Category: | Cable Box |
| Model: | BUDI-M-TH (Installation Instruction), prONxUUYRGh/2 |
| File Type: | |
| File Size: | — |
| Pages: | 8 pages |
Download PDF
Download CommScope BUDI-M-TH Manual (8 pages)Read Online:
Read the CommScope BUDI-M-TH Installation Instruction online using the built-in PDF viewer.
Key Pages of Document
Building distributor Box • SC/APC adapters (100 pieces) • = SC/APC 2 m pigtails (96 pieces) • Foam (1 mm) • Hook and loop fastener (6 pieces) Suitable for FTTH applications where easily pre-connectorized splitters modules can be built-in. The box is designed to accommodate both spliced and conn ...
loose tube to be spliced to the splitter inputs. 3 Installation of feeder cable 3.2 Use the two guiding pins found on the inside of the box cover to open the ports. Cut out the plastic. 3.3 Make a window cut of 2.7 m. 3.4 Prepare the two cable brackets as shown. 3.5 Apply the hook and l ...
3.8 Apply the foam around the looped cable. 3.9 Install the looped cable into the ports and close the seal. 3.10 Install the second cable bracket and secure together with two pins (slide through holes). 3.11 Install the edge protection. 3.12 Take out one loose tube. 3.13 Use a wedge to support the tra ...
3.15 Apply the foam and secure the loose tubes together with the two tie wraps. Select the fibers to be spliced to the inputs of the OCM6 splitters and cut them off (do not cut the feeder side). 3.14 Mark the loose tube at marked position and shave the tube (make sure that the unshaved part of the tube is long enough to be a ...
foam and secure with the tie wrap. Splice the fibers and store the overlength into the tray. 4.4 Install the cover and secure with the two screws. 4.5 Guide the outputs of the OCM6 splitters through the wire saddle. 4.6 Connect the outputs of the OCM6 splitter to the designated adapters. 4 ...
5.1 Prepare the seal port. 5.2 Prepare the riser cable to be installed into the box. 5.3 Install the riser cable into the box on the metal bracket and secure with the two tie-wraps. 5.4 Close the seal. 5.5 Install the 900 µm pigtails into the tray. ...
tie-wraps. 5.7 Strip the pigtails at the marked position. 5.8 Splice all the fibers and store the overlength into the tray. 5.9 Install the cover onto the tray and secure with the two screws. 5.9 Install the cover onto the tray and secure with the two screws. ...
All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. This product is covered by one or mor ...
⚠️ Download Safety
The Cable Box Installation instruction (8 pages) is completely safe to download (last scan date: 08/06/2026).
Related PDF Instructions for CommScope BUDI-M-TH:
-
CommScope DB5091-3 Racks & Stands Instruction sheet, 2 pages
-
CommScope FIST-RSKG-16 Cables and connectors Installation instructions, 4 pages
-
CommScope 3RU Power distribution unit Operation & user’s manual, 54 pages
-
CommScope QWIK MPO Series Cables and connectors Termination instructions, 13 pages
-
CommScope F-042-GL-E Antenna Instruction sheet, 8 pages
-
CommScope ARRIS SURFboard SB8200 Modem Operation & user’s manual, 32 pages