Emerson FB2100 Field Replacement Manual
Read Online
Read the Emerson FB2100 Field Replacement Manual online using the built-in PDF viewer.
Key Pages of Document
D301848X012 November 2020 Remote Automation Solutions FB2100/FB2200 Flow Computer Internal Solar Regulator Field Replacement Guide For Part Numbers (Kits): 399296-01-0: Internal Solar Regulator ...
D301848X012 November 2020 Device Safety Considerations Reading these Instructions Before operating the device, read these instructions carefully and understand their safety implications. In some situations, improperly using this device may result in damage or injury. Keep this manual in a convenient location for future reference. Note that these instructions may not cover all ...
D301848X012 November 2020 1 Removing/Replacing the Internal Solar Regulator You can optionally install an internal solar regulator (charger) in the flow computer for use with a 30W solar panel. The internal solar regulator mounts to the inside of the battery compartment. Refer to the table below for the correct field replacement part number. Item UL Field Replacement Kit Part Numb ...
D301848X012 November 2020 2 Important This procedure involves removing several screws. We recommend you provide a container to catch and hold screws when you remove them. Removing/Replacing the Internal Solar Regulator 1. Open the flow computer enclosure. The solar regulator mounts inside the battery compartment. 2. Open the battery compartment by loosening the two captive fasteni ...
D301848X012 November 2020 3 4. Now remove the four screws that attach the solar regulator to the battery compartment. These are located at the left side of the battery compartment, and on the exterior right side of the battery compartment. 5. Now that you can move the solar regulator, carefully move its left edge so it sits in front of the left tab for the captive fastening screws ...
D301848X012 November 2020 4 6. You should now be able to pull regulator out of the battery compartment and set it aside. 7. Take the new (replacement) solar regulator, and if present, remove its termination cover. 8. Connect wiring as described in Wiring the Internal Solar Regulator, but leave the termination cover off. 9. Maneuver the new replacement solar regulator between the t ...
D301848X012 November 2020 5 Wiring the Internal Solar Regulator ...
D301848X012 November 2020 For customer service and technical support, visit www.Emerson.com/SupportNet Global Headquarters, North America, and Latin America: Emerson Automation Solutions Remote Automation Solutions 6005 Rogerdale Road Houston, TX 77072 U.S.A. T +1 281 879 2699 | F +1 281 988 4445 www.Emerson.com/RemoteAutomation © 2018-2020 Remote Automation Solutions, a business ...