D301824X012 November 2020 Remote Automation Solutions FB2100/FB2200 Flow Computer 30W Solar Panel Field Replacement Guide For Part Numbers (Kits): 395555-02-7: Solar Panel 399288-01-0: Battery Cable 396701-03-0: Solar Controller Cable 395829-01-0: Fuses 396992-01-3: Solar Controller ...
D301815X012 November 2019 Remote Automation Solutions Device Safety Considerations Reading these Instructions Before operating the device, read these instructions carefully and understand their safety implications. In some situations, improperly using this device may result in damage or injury. Keep this manual in a convenient location for future reference. Note that these instructions may not ...
D301824X012 November 2020 1 Replacing the 30W Solar Panel The procedure for replacing the 30W solar panel on the FB2100/FB2200 Flow Computer re-uses the existing mounting hardware provided with the original solar panel. Save any mounting hardware/screws/nuts/washers from the original. Restrictions Hazardous area approvals require that any part replaced in the field be the exact same part ( ...
D301824X012 November 2020 2 Removing/Replacing the 30W Solar Panel UL Listed Field Installed Accessory Kit for Use in Class I, Division 2, Groups A, B, C, and D Flow Computer 30W Solar Panel Field Installed Accessory Kit Part No. 395555-02-7 for Use with UL Listed Class I, Division 2, Groups A, B, C, and D Model Series FB2100 and FB2200. The procedure for replacing the 30W solar panel ...
D301824X012 November 2020 3 7. Set the tilt angle of the panel for maximum solar exposure. (See Setting the Tilt Angle) Removing/Replacing the Solar Controller UL Listed Field Installed Accessory Kit for Use in Class I, Division 2, Groups A, B, C, and D Flow Computer Solar Controller Field Installed Accessory Kit Part No. 396992-01-3 for Use with UL Listed Class I, Division 2, Groups A ...
D301824X012 November 2020 4 1 Junction Box controller 2 Knock-outs 3 Lock nut 5. Use the solar controller lock nut to attach the solar controller to the junction box and use a 7/32” flat head screwdriver to attach the wires from the controller to the junction box connectors as shown. 6. Route the BATT+ and BATT– wires from the flow computer into the junction box. ...
D301824X012 November 2020 5 1 Battery wires from the flow computer 7. Connect the wires as shown. Replace the junction box cover. Note Wire in accordance with Article 501.10 (B) of the NEC. ...
D301824X012 November 2020 7 Adjusting the Tilt Angle The mounting brackets allow you to adjust the solar panel for maximum solar exposure. You can adjust the swivel of the panel by adjusting the U-bolt. To adjust the tilt angle, loosen the four (4) nuts in the adjustable angle bracket and move the panel to the desired tilt angle. The paragraphs that follow discuss how to choose the tilt an ...
D301824X012 November 2020 8 Solar Panel Tilt Angle Latitude Installation Angle 0 to 4° 10° from horizontal 5 to 20 Add 5° from the local latitude 21 to 45° Add 10° from the local latitude 46 to 65° Add 15° from the local latitude 66 to 75° 80° from horizontal Removing/Replacing the Solar Controller Cable and Battery Cable UL Listed Field Installed Accessory Kit for Use in Class I, ...
D301824X012 November 2020 9 5. Pull the solar controller cable and battery cable out of the BATT terminals on terminal block TB2. 6. Attach the replacement cable(s) to the BATT terminals on terminal block TB2. Follow the wiring guidelines in the flow computer instruction manual and wire the connections as shown in the wiring graphic on page 6 (for solar cabling) or page 9 (for battery cabl ...
D301824X012 November 2020 10 4. With the thumb and index finger on your other hand, twist the other end of the fuse holder counterclockwise to separate the two halves of the fuse holder. 5. Pull out the old fuse and discard it. 6. Put the new fuse in the holder and put the two ends of the holder together. 7. Twist the threaded end clockwise until the fuse holder is closed. ...
D301824X012 November 2020 11 8. Press the cable back into the enclosure; ensure it does not get caught in the enclosure door. 9. Close the flow computer enclosure. ...
D301824X012 November 2020 For customer service and technical support, visit www.Emerson.com/SupportNet Global Headquarters, North America, and Latin America: Emerson Automation Solutions Remote Automation Solutions 6005 Rogerdale Road Houston, TX 77072 U.S.A. T +1 281 879 2699 | F +1 281 988 4445 www.Emerson.com/RemoteAutomation © 2018-2020 Remote Automation Solutions, a business unit of ...