Installation and Configuration

3.0.2 / 090504 English Audio and video recorder DLS 4 DLS 8 / 8 PLUS DLS 16 / 16 PLUS ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

2 Dallmeier electronic Information about copyright, trademarks, design patents © 2009 Dallmeier electronic All rights reserved. This document may not be copied, photocopied, reproduced, translated, transferred to an electronic medium or converted to a machine-readable form either whole or in part without first receiving written permission from Dallmeier electronic GmbH & Co.KG. We reserve the right to make technical modifications. The manufacturer accepts no liability for damage to property or pecuniary damages arising due to minor defects of the product or documentation, e.g. print or spelling errors, and for ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

3 Dallmeier electronic Table of contents 1 This document 8 1.1 Validity 8 1.2 Documentation 8 1.3 Convention 8 2 For your safety 10 3 General instructions 12 3.1 Scope of delivery 12 3.2 Transportation and packaging 12 3.3 Warranty 12 4 Installation and mounting 13 4.1 General Requirements 13 4.2 Stand-alone installation 13 4.2.1 Requirements 13 4.2.2 Installation 13 4.3 Rack mounting 14 4.3.1 Requirements 14 4.3.2 Mounting 15 5 Connection 16 5.1 Connection assignment 16 5.2 Power supply 17 5.3 Cameras 17 5.4 Monitors 18 5.5 Audio 18 5.6 Mouse and keyboard 19 5.7 Contact IN 19 5.7.1 Global contacts 19 5.7.2 Con ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

4 Dallmeier electronic 7.4.2.2 Performance 32 7.4.2.3 Tracking 32 7.4.3 Keyboard mode 33 7.4.4 Single split replay 33 7.4.5 Playback monitor 34 7.4.6 System messages 34 7.4.7 Assistant mode 35 7.4.8 Recording timeout 36 7.4.9 OSD texts 37 7.4.10 Logging 39 7.4.11 Simple Export 39 7.4.12 Recording monitoring 40 8 Recording setting 41 8.1 Track mode 41 8.1.1 Standard 42 8.1.1.1 Recording 42 8.1.1.2 Modifications 42 8.1.1.3 Track types 42 8.1.1.4 Recording modes 43 8.1.2 Manual 43 8.1.2.1 Recording 43 8.1.2.2 Modifications 44 8.1.2.3 Track types 44 8.1.2.4 Recording modes 44 8.1.3 Automatic 44 8.1.3.1 Recording 45 ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

5 Dallmeier electronic 8.7.1.1 Longplay tracks 63 8.7.1.2 Secure tracks 64 8.7.2 Manual 65 8.7.3 Automatic 65 8.8 Other functions 66 8.8.1 Audio 66 8.8.2 Dual Streaming 66 8.8.3 SmartFinder 66 8.8.4 Camera control 68 9 Display settings 69 9.1 Recorder and camera description 69 9.2 Splitter 70 9.2.1 Automatic assignment 71 9.2.2 Manual assignment 71 9.3 Sequencer 72 9.3.1 VGA display sequence 72 9.3.2 CVBS display sequence 73 9.3.3 Display frame rate 74 10 Network and PAS 75 10.1 Ethernet 75 10.2 PSTN/Terminal Adapter 76 10.3 Alarm hosts 76 10.3.1 Selection and name 76 10.3.2 Connection 77 10.3.3 Alternative ala ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

6 Dallmeier electronic 14.3 Storage System 102 14.4 Weather server 103 14.5 Dallmeier network interface 103 14.5.1 DNI - external system 103 14.5.2 DNI - camera control 105 14.6 UPS 106 14.6.1 Serial UPS 106 14.6.2 UPS configuration 107 14.7 Card reader 107 14.8 VSC 108 15� Configuration�of�optional�functions� 109 15.1 Signal loop through 109 15.2 UTC camera configuration 109 15.2.1 Required settings 110 15.2.2 Control panel 110 15.2.3 Zoom function 111 15.2.3.1 Save zoom factor and position 111 15.2.3.2 Enter name for position 112 15.2.4 Configure camera 112 15.2.4.1 Functions 113 15.2.4.2 Close menu ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

7 Dallmeier electronic 21 Technical data 135 22 Pin assignment 137 23 Technical drawing 138 ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

8 Dallmeier electronic 1 This document 1.1 Validity This document applies to the audio and video recorder DLS 4 / DLS 8 / DLS 8 PLUS / DLS 16 / DLS 16 PLUS. It has been produced on the basis of version 6.3.0 (software). The descriptions in this document apply to all above-mentioned models. For simplification reasons, the term "DLS" is thus used. If text passages require distinctions to be made bet- ween the devices, the complete device name will be mentioned. 1.2 Documentation Commissioning The document entitled Commissioning contains the most important steps for the connection and commissioning of the device. ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

9 Dallmeier electronic IMPORTANT The word IMPORTANT denotes information for preventing damage, incorrect configurations or incorrect actions. NOTE A NOTE offers information on principles, special features and efficient procedure as well as general recommendations. Expression Expressions in bold and italics generally indicate a control ele- ment on the device (switches or labels) or on its user interface (buttons, menu entries). ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

10 Dallmeier electronic 2 For your safety Only use this unit if it is technically in proper working order, to the intended purpose and while keeping safety and potential dangers in mind. Have malfunctions or damages elimi- nated immediately! Appoint a professional Installation, mounting, connection, start-up and configuration of the unit may only be carried out by trained and authorized professionals (installers). Unless otherwise expressly specified, this also applies to the maintenance, testing and repair. In doing do the regulations of the DIN VDE 0701 series of standards (repair, modification and inspection ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

11 Dallmeier electronic Expansion components/peripheral devices Use only expansion components conforming with the technical data of the unit. Inappropriate peripheral devices may result in the violation of local laws and regulations and damages to the unit. Furthermore, the use of peripheral devices that are not certified by Dallmeier electronic results in loss of warranty. In case of doubt, contact the sales partner responsible for your area. Do not move while in operation Strong vibrations can cause damage to the unit, in particular to the hard disk(s). Therefore, do not bump the unit or move it in a jerky mo ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

12 Dallmeier electronic 3 General instructions 3.1 Scope of delivery Included in the standard scope of delivery is: 1 x Recorder including HDDs (as ordered) 1 x Dallmeier mouse (optical, small version) 1 x 12V power supply unit including mains cable (differs from country to country) 1 x 9-pin D-SUB interfaces with housing 2 x 18 pin. Weidmüller Plug connector 1 x 2 pin. Weidmüller Plug connector 1 x Audio cable frame (2 x for 16-channel recorder) 1 x PS/2 Y-adapter 1 x Spare set of filters (5 filters) 1 x "Installation and Configuration" documentation (CD) 1 x "Operation" documentation (CD) 1 x Quick guide � ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

13 Dallmeier electronic 4 Installation and mounting The DLS is designed for stand-alone operation. As an option it may also be installed in a 19“ standard rack. 4.1 General Requirements Unfavorable local conditions may shorten the life of the product or lead to malfunctions. Do not operate DLS at places l with large scale dust and dirt l with steam or oil vapors (e.g. kitchen) l with direct sunlight l with unsuitable ambient temperatures l near sources of strong radiation (e. g. X-rays, radio transmitters or magnetic fields) l with corrosive surroundings (e.g. gases or salt water) l with insufficient ventilat ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

14 Dallmeier electronic Fig. 4-1 Ø Establish the required connections as described in the following. Ø Start-up and login for configuration as described in the following. 4.3 Rack mounting The DLS can be installed in a 19“ standard rack using two 19’’ mountings (option). 4.3.1 Requirements Elevated operating ambient The operating ambient temperature in a multi-unit rack may be greater than the room ambient. Ensure that the maximum ambient temperature in the rack complies with the requirements specified in the technical data. Reduced�air�flow The air flow in a (closed) rack may be reduced. Ensure tha ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

15 Dallmeier electronic Reliable earthing Ensure a reliable earthing of the DLS. Use power strips when other supply connections than direct connections to the branch circuit are being used. 4.3.2 Mounting Ø Remove the four side housing screws. Fig. 4-2 Ø Place the two 19“ mountings against the housing. Fig. 4-3 Ø Secure the 19“ mountings to the housing using the removed screws. Ø Install the device in the 19“ rack. IMPORTANT Follow the instructions supplied by the rack manufacturer. Ø Do not mount the DLS upside down. Ø Ensure a stable and horizontal mounting. Ø Ensure sufficient ventilation with 4 ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

16 Dallmeier electronic 5 Connection The following describes special features for connecting the basic peripherals. See also the technical data in the annex. Information about the connection and configuration of optional peripherals is provided in separate sections. NOTE Before connecting the device, ensure that the recorder and the peripherals are disconnected from the power supply. 5.1 Connection assignment NOTE The number of connections can differ depending on the ordered equipment or device variant. The following description relates to a device with full equipment. 1 12V IN (2-pin ODU jack) 2 Serial interfa ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

17 Dallmeier electronic 12 Audio OUT 1 Live and playback (3,5 mm phone jack) 13 Audio OUT 2 Live and playback (3,5 mm phone jack) (inaktiv) 14 Video IN C1 – C16 (BNC) 15 Serial interface RS485 (2-pin Weidmüller pin strip) 16 Contact IN (18-pin Weidmüller pin strip) 17 Relay OUT (18-pin Weidmüller pin strip) 18 HDD1 interchangeable drawer unit 19 HDD2 interchangeable drawer unit 20 Line/AUX IN intercom (3,5 mm phone jack) 21 Audio OUT intercom (3,5 mm phone jack) 5.2 Power supply The DLS is powered with the required voltage of 12V DC by a PSU (power supply unit). This PSU is able to absorb short�voltage� ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

18 Dallmeier electronic Please note that in the basic configuration, all analog video inputs on the recorder are ter- minated. If a camera signal is forwarded to an optional device (signal loop), the termination must be cancelled (see section entitled Configuration�of�optional�periphery). 5.4 Monitors For connecting a monitor a distinction must be made between the various video outputs (CVBS and VGA) and their respective functions. VGA The VGA monitor is connected using the VGA output (6). The VGA monitor can provide various functions depending on the operating mode of the recorder: Sequencer/Livemode Dis ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

19 Dallmeier electronic 5.6 Mouse and keyboard The mouse and keyboard can be connected either to a USB port or to the PS/2 port. USB Ø Connect the mouse and / or keyboard to any USB port (8). PS/2 Ø Connect the mouse and / or keyboard to the Y-cable. Ø Connect the Y-cable to the PS/2 port (9). 5.7 Contact IN The Contact IN interface (16 and 17) allows various recorder functions to be started and controlled by external devices. The following specifications apply for all contact inputs: l Interfering pulses < 10 ms are filtered out l Contact input must be < 1V for low level at 1 mA l VdS calms a contact durati ...

DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS

20 Dallmeier electronic Contact inputs G1 to G6 are known as global contacts. The outer pins on the plug connector strip are connected to ground. The pins on contacts G1 to G6 are arranged from left to right. In contrast to the camera-related contact inputs, the global inputs are not pre-assigned. The function that the contact should have can be set using Setup > Interfaces > Contact IN. 5.7.2 Contacts for individual cameras Contact inputs 1 to 16 are known as camera-related contact inputs. The outer pins on the plug connector strip are connected to ground. The pins on contacts 1 to 16 are arranged from left to ...

Measuring Instruments PDF Instructions

480846
Extech Instruments 480846
30.06.2026 16 pages

User's Guide RF EMF Strength Meter Model 480846 Product usage guide for the Extech Instruments 480846 Measuring Instruments. The document includes compatibility information, device features, installation procedures, dimensions and layout.

PRS-370 SERIES
IET Labs PRS-370 SERIES
09.04.2026 54 pages

♦ PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT ♦ TEL: (516) 334-5959 • (800) 899-8438 • FAX: (516) 334-5988 www.ietlabs.com IET LABS, INC. PRS-370 SERIES Programmable Decade Resistance Substituter (IEEE-488.2, Ethernet and USB) Operation Manual Instructions for safe usage of the IET Labs PRS-370 SERIES Measuring Instruments. The manual details detailing setup, operation, performance details, power requirements.

EPM6000
GE EPM6000
22.05.2026 128 pages

EPM 6000 Multi-function Power Metering System Chapter 1: Digital Energy Multilin Instruction Manual Software Revision: 1.17 Manual P/N: 1601-0215-A5 Manual Order Code: GEK-106558D Copyright © 2010 GE Multilin GE Multilin 215 Anderson Avenue, Markham, Ontario Manual for safe operation of the GE EPM6000 Measuring Instruments. It provides guidance on device instructions, safety guidelines, installation steps, cleaning instructions.

CO-OPM-48
ChallengerOptics CO-OPM-48
22.06.2026 15 pages

ChallengerOptics.com Wavelength Specific Optical Testing and Measurement Equipment Optical Power Meter - Fiber Deep DWDM Operating Manual ChallengerOptics CO-OPM-48 020119 Instruction reference guide for the ChallengerOptics CO-OPM-48 Measuring Instruments. The manual includes instructions for adjustment procedures, firmware updates, product maintenance.