NetVanta Series (with E1/FE1 or E1/FE1 + G.703 Drop Network Interface Module) Quick Configuration Guide 64200868L1-42C March 2005 • Category 5 - UTP cable for connecting the system to the existing network. • VT100 terminal or PC with VT100 emulation software. • DB-9 (male) to DB-9 (female) straight-through cable for configuring the unit. Frame Relay Diagram PPP over Fractional E1 Connection Diagram Equipment Required ...

Technical Support +1-256-963-8716

64200868L1-42C The NetVanta may be initially accessed and managed either via a console session or through a Telnet session. Refer to Initiate a Console Session for console session instructions. Initiating a Telnet session requires using a hub and two Ethernet cables (one for the PC and one for the unit). The default Ethernet IP address is 10.10.10.1. Refer to Configure Telnet Access on page 7 to change Telnet session se ...

Technical Support +1-256-963-8716

3 1. At the (config)# prompt, enter interface e1 1/1 to activate the interface configuration mode for the E1 network interface. 2. If necessary (this is the default), enter clock source line to configure the unit to recover clocking from the E1 network connection. 3. If two units are configured on a private E1 (PPP mode), set one unit to clock source line and the other to clock source internal. For Frame Rel ...

Technical Support +1-256-963-8716

64200868L1-42C 1. Enter interface e1 1/2 to activate the interface configuration mode for the DSX-1 interface. 2. Enter multiframe ts16 to verify the G.703 interface is configured for voice signaling (timeslot 16 used for signaling). 3. Enter no shutdown to activate the G.703 interface. 4. Enter exit to return to the Global Configuration mode. The following steps outline configuring a Frame Relay virtual interface (label ...

Technical Support +1-256-963-8716

5 The following steps show how to configure a PPP virtual interface (labeled 1) to the corporate router. Skip to Create the Cross-Connect below if you are using Frame Relay. 1. At the (config)# prompt, enter interface ppp 1 to create a PPP virtual interface labeled 1. 2. Enter ip address 192.168.72.1 255.255.255.252 to assign an IP address to the PPP endpoint using a 30-bit mask. 3. Enter no shutdown to acti ...

Technical Support +1-256-963-8716

64200868L1-42C 2. The internet router at the far side will need a route statement to send traffic back to this network through the NetVanta router. The information (based on the diagram shown at the beginning of this document) is as follows: • Destination address: 10.10.20.0 (remote LAN) • Subnet mask: 255.255.255.0 • Gateway: 10.10.10.1 (NetVanta Router’s Ethernet) Scenario 1: Dynamic Routing via OSPF 1. At the ...

Technical Support +1-256-963-8716

7 The following steps show how to access the Telnet configuration parameters and change the password. The default password for initializing a Telnet session is password (all lowercase). For security purposes, change the password to something unique. For this example, replace the underlined word with a password of your choosing. The NetVanta supports five Telnet sessions (0 through 4). 1. Verify that the prom ...