IMC MF5 Installation, Operating And Servicing Instructions
Text of the manual
Installation, Operating and Servicing
Instructions
A34/003 R1
A34/003 R2
ECN 4825 February 2021
MF5, MF10 & MF15 – SERIES 1
Please make a note of your product details for
future use:
Date Purchased:_________________________
Model Number:__________________________
Serial Number:__________________________
Dealer:_________________________________
____________
Page 2 of 14
CONTENTS
IMPORTANT INFORMATION .......................................................................... 3
DELIVERY ............................................................................................................ 4
INTRODUCTION .................................................................................................. 4
DIMEN
Page 3 of 14
IMPORTANT INFORMATION
Read these instructions carefully before using this product, paying particular
attention to all sections that carry warning symbols, caution symbols and notices.
Ensure that these are understood at all times.
WARNING!
This symbol is used whenever there is a risk of personal injury.
CAUTION!
This symbol is used whenever ther
Page 4 of 14
The packaged machine consists of:
Peeler Unit
1
Peeling plate
1
Stand and filter basket
1 (MF10 and MF15 only)
Water supply pipe and fixings
1
Instruction Booklet
1
Gritted Liners on L units only
2
Please notify both the carrier and the supplier within 24 hours of receipt if anything is
missing or damaged.
Check that the correct machine has been
Page 6 of 14
For the Installer:
These Instructions contain important information designed to help the user obtain
the maximum benefit from the investment in an IMC MF Peeler.
Please read them carefully before starting work, and consult with the supplier in the
event of any queries.
Be sure to leave this Instruction Manual with the user after installation of
Page 7 of 14
Stand installation
The MF10 & MF15 are supplied mounted on floor standing stands that
incorporate filter baskets. The stand should be levelled using the adjustable feet. It is
possible to fix the stand to the floor, if required, by screwing through to holes in the feet.
The waste is discharged from the waste hose via a Filter Basket into the dra
Page 8 of 14
The wires in the mains lead for three phase supply are coloured:
Green and Yellow
Earth
Black
Phase 1
Grey
Phase 2
Brown
Phase 3
The 3 phase machines do not have a neutral wire, if the supply has a neutral wire
isolate it and only wire the unit to the 3 phases and earth.
An equipotential bonding terminal is provided at the back of the unit near
Page 9 of 14
MF Range Universal Peelers are particularly easy to use, and feature a safety
specification that prevents the operator touching any moving parts during operation.
The operating procedure is as follows:
1
Fit the appropriate bottom plate, ensuring that it is properly located on the drive
shaft.
2
Load the peeling chamber with the vegetables to be
Page 10 of 14
1
Washing Plate - used for washing new crop potatoes and carrots, or main crop
potatoes that are to be cooked without peeling, for example jacket potatoes.
Cannot be used with liner versions.
2
Mussel Washing Plate - this plate cleans all but the most stubborn dirt from
mussels prior to cooking. Cannot be used with liner versions.
3
Knife Peeli