Festo CDVI Series Brief Description
File Specifications
| Brand: | Festo |
| Category: | Control Unit |
| Model: | CDVI Series (Brief Description), prrIho9dsxPkM |
| File Type: | |
| File Size: | — |
| Pages: | 10 pages |
Download PDF
Download Festo CDVI Series Manual (10 pages)Read Online:
Read the Festo CDVI Series Brief Description online using the built-in PDF viewer.
Key Pages of Document
with multipin connector – English 8080200 2017-12d [8080193] Valve terminal type 15 ...
2 Translation of the original instructions Documentation on the product For all available product documentation � www.festo.com/pk Copyright: Festo SE & Co. KG Ruiter Straße 82 73734 Esslingen Germany Internet: �http://www.festo.com E-Mail: �[email protected] Reproduction, distribution or sale of this document or c ...
3 1 User instructionsEnglish The CDVI has been designed exclusively for controlling pneumatic actuators. The maximum values specified in the section “Technical specifications” must be observed here. Detailed information can be found in the Pneumatics manual P.BE-CDVI-... . Warning � Switch off the power supply before co ...
4 2 Multi-pin connection 2.1 Multi-pin plug Each valve solenoid coil must be assigned to a specific pin of the multi-pin plug in order that the valves can be actu ated. A valve position always occupies two addresses on the base block, irrespective of whether it is fitted with a blanking plate, separator plate or valve sub-b ...
5 The multi-pin plug is fitted in the left-hand end plate at the factory. The following diagram shows the pin numbering of the multi-pin plug in the left-hand end plate of the valve ter minal (view of plug): A01 A10 B10 C10 C01 B01 2.2 Pin allocation of the multi-pin plug Notes on the following table: – Designation of the ...
6 Please note the following addressing rules: The following table shows the address assignment of the manifold blocks. Further address assignment depends on the type of the expansion block. 2 Bi-expansion block = 4 addresses 2 Mo-expansion block = 2 addresses 1 Bi-expansion block = 2 addresses 1 Mo-expansion block = 1 address C ...
7 Pin Address Core colour Valve location/sole noid coil Pins Sub-D 37-pin 4-group manifold block 8-group manifold block Test adapter A01 A02 B01 B02 C01 C02 A03 A04 B03 B04 C03 C04 A05 A06 B05 B06 C05 C06 A07 A08 B07 B08 C07 C08 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 WH GN YE GY PK BU RD VT GY PK RD B ...
8 3 Controlling the valve terminal Use a uniform method of control. Preferably all control signals should be positive-switching (1-switching), other wise all control signals negative-switching (0-switching). Mixed mode control is not permitted. 3.1 Address assignment of the valves – Assign the addresses in ascending order w ...
9 1 0 3 2 5 4 7 6 9 8 11 10 12 13 14 15 1214 1214 1214 1214 1214 14 1214 4 3 2 1 5 6 7 1 4-group manifold block 2 2 Bi-expansion block 3 2 Mo-expansion block 4 1 Bi-expansion block 5 Addresses of the solenoid coils 6 Reserve location on the Mo-expansion block (occupies 1 address) 7 Reserve location on the 4-group manifold blo ...
10 4 Technical specifications Type CDVI5.0-... Dimensions See Pneumatics Manual Number of valve positions 4, 6, 8, 10, 124) / 4, 5,...165) Control voltage: – Rated value (protected against incorrect polarity) – Tolerance – Total permitted current 24 V DC ± 10 % (21.6 V ... 26.4 V DC) 2880 mA Protection class with comple ...
⚠️ Download Safety
The Control Unit Brief description (10 pages) is completely safe to download (last scan date: 23/03/2026).