Cross Technologies 2017-03A Instruction Manual

File Specifications

Brand: Cross Technologies
Category: Media Converter
Model: 2017-03A (Instruction Manual), prIACx34E/U9Q
File Type: PDF
File Size: —
Pages: 21 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (21 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 24/03/2026).

Read Online

Read the Cross Technologies 2017-03A Instruction Manual online using the built-in PDF viewer.

Key Pages of Document

Instruction Manual Model 2017-03A

Up/Downconverter July 2019, Rev. I MENU EXECUTE MODEL 2017 CROSS TECHNOLOGIES INC. U F=1525 G=+00 D F=1525 G=+25 MUTE UPCONVERTER DOWNCONVERTER REMOTE ALARM POWER ALARM UP/DOWNCONVERTER Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purpos ...

MODEL 2017-03A Up/Downconverter

TABLE OF CONTENTS PAGE Warranty 2 1.0 General 3 1.1 Equipment Description 3 1.2 Technical Characteristics 4 1.3 Monitor & Control Interface 5 1.4 Environmental Use Information 8 2.0 Installation 9 2.1 Mechanical 9 2.2 Rear I/O’s 10 2.3 Front Panel Controls, Indicators 12 2.4 Operation 13 2.5 Menu Settings 15 WARRANTY - The following warranty applies to all Cross Technologies, Inc. ...

MODEL 2017-03A Up/Downconverter

1.0 General 1.1 Equipment Description The 2017-03A L-band Up/Downconverter converts 70 MHz to 950-1525 MHz (Up) and 950-1525 MHz to 70 MHz (Down) in 1 MHz steps with low group delay and flat frequency response. The 2017-03A has lower RF level out of the upconverter and higher RF level into the downconverter than the 2017-03 and is typically used to interface an L-band modem to a 70 MHz IF upconverter and downconverter. Mul ...

1.2 Technical Characteristics

TABLE 1.0 2017-03A Up/Downconverter Specifications* ---UPCONVERTER--- Input Characteristics (IF) Impedance/Return Loss 75 Ω /18 dB Frequency 70 ± 18 MHZ Input Level -40 to -10 dBm Output Characteristics (RF) Impedance/Return Loss 75 Ω/12 dB Frequency 950 to 1525 MHz Output level -35 to -15 dBm Output 1 dB compression -10 dBm Channel Characteristics Gain range (adjustable) -25 to +15 dBm, 1 dB steps Frequency Sense Non-i ...

1.3 Monitor and Control Interface

A) Remote Serial Interface Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit. (RS-232C, RS-422, or RS-485 - option Q) 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 Female DB-9 PC Com Port Male DB-9 2015/16/17 M&C Port M&C Cable Diagram - Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector: Rear panel, DB-9 male J10 Pinouts (RS-232C/422/485) Pinouts (RS-232C/4 ...

B) Status Requests

Table 1.1 lists the status requests for the 2017-03A and briefly describes them. * PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below, should be used ONLY when RS-485, (OPTION-Q), is selected. Table 1.1 2017-03A Status Requests Status Requests Command Syntax* Description Command Status {aaS1} Returns {aaS1bbbbccccdddeeffLMNOP} where: • bbbb = Tx frequency 4 characters - standard (7 characters - Option-X) • cc ...

Table 1.2 lists the commands for the 2017-03A and briefly describes them. After a command is sent the

2017-03A sends a return “>” indicating the command has been received and executed. General Command Format - The general command format is {aaCND...}, where: { = start byte aa = address (RS-485 only option Q) C = 1 character, either C (command) or S (status) N = 1 character command or status request D = 1 character or more of data (depends o ...

1.4 Environmental Use Information

A. Elevated operating ambient temperature - if installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature. Therefore, consideration should be given to Tmra. B. Reduced air flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional spa ...

2.1 Mechanical - The 2017-03A consists of one RF/Controller PCB housed in a 1 RU (1 3/4 inch high) by 16

inch deep chassis. A switching, ± 12, +5, +24 VDC power supply provides power for the assemblies. The 2017- 03A can be secured to a rack using the 4 holes on the front panel. Figure 2.0 shows how the 2017-03A is assembled. POWER SUPPLY Figure 2.0 Model 2017-03A Mechanical Assembly 2017-03A Manual, Rev. I Page ...

2.2 Rear Panel Input/Output Signals and Control -

Figure 2.2 shows the input and output connectors on the rear panel. AC GND J18 J2 RF IN 10 MHZ REF OUTPUT AC1 - POWER IN AC input for switching power supply. 100-240 ± 10% VAC, 47-63 Hz. J2 - RF IN 950-1525 MHz input, -60 to -10 dBm, see Table 2.2. J1 - IF OUT 70 MHz output, -10 to 0 dBm, See Table 2.2. J10 AND MONITOR CONTROL J10 - MONITOR AND CONTROL DB9 female connector. see Table 2.1. RF OUT J4 J5 J3 ...

Tables 2.1, 2.2 & 2.3 show the input and output connectors on the rear panel.

TABLE 2.1 J10 2.1 J10 Pinouts (RS-232C/422/485*) Pin Function 1 Rx- 2 Rx+ (RS-232C) 3 Tx+ (RS-232C) 4 Tx- 5 GND 6 Alarm Relay: Common 7 Alarm Relay: Normally Open 8 Not Used 9 Alarm Relay: Normally Closed TABLE 2.3 DC1 TABLE 2.3 DC1 Pinouts Pin# Function 1 Minus DC input 2 NC 3 Plus DC input 4 NC Shell Ground *Remote Serial Interface Interface: DB-9 Male Protocol: RS-232C (RS-485 ...

2.3 Front Panel Controls and Indicators -

The following are the front panel controls and indicators. MENU EXECUTE U F=1525 G=+00 MUTE REMOTE ALARM POWER LCD DISPLAY Display shows Up and Downconverter frequency in MHz and Gain in dB S1 - MENU/EXECUTE BUTTON Press this to get into Program mode and to execute any changes. DS3 - DOWN ALARM LED Red LED indicates downconverter alarm. DS6 - POWER LED Green LED indicates presence of DC power. DS1 - REMOTE LE ...

2.4 Installation / Operation

2.4.1 Installing and Operating the 2017-03A, Upconverter Section 1.) Connect a -40 dBm to -10 dBm signal to IF In, J4 (Figure 2.1). 2.) Connect the RF OUT, J5, to the external equipment. 3.) Connect 100 - 240 (±10% VAC), 47 - 63 Hz to AC on the back panel. 4.) Set the desired output frequency (See Section 2.5 Menu Settings). 5.) Set the input level (See Section 2.5 Menu Settings). 6.) (option V) To power the SSPB (+24 VDC, ...

AC Fuse - 2 amp slow blow (Type T),

5 mm X 20 mm FUSE DRAWER SPARE FUSE ~ INPUT 100-240± 10%VAC 47-63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100 - 240 V~ ~ Figure 2.3 Fuse Location and Spare Fuse 2017-03A Manual, Rev. I Page 14 07/22/19 ...

2.5 Menu Settings

2.5.1 Functions - This section describes operation of the front panel controls. There are three operator switches, the LCD display and alarm indicator LEDs. All functions for the equipment are controlled by these components. The functions are (see Figure 2.2): Power Up Normal Display Menu 1 Up Frequency in MHz Menu 2 Up Input Lvl (Set from -45 to -15) Menu 3 Down Frequency in MHz Menu 4 Down Gain (set 0 to +50 for -10 to 0 dBm out ran ...

2.5.2 Power-On Settings

NOTE: THE LAST STATUS OF A UNIT IS RETAINED EVEN WHEN POWER IS REMOVED. WHEN POWER IS RESTORED, THE UNIT WILL RETURN TO IT'S PREVIOUS SETTINGS. When power is first applied, the LCD display goes through three steps. 1. The LCD goes black to show all segments are functioning. 2. The software version will be displayed. R E V 1 . 0 0 3. The present frequency and gain of the up and downconverter is shown. U F=1350 G=+00.0 D ...

2.5.4 Frequency Changes

At any time during the modification process, if you have made a mistake and do not wish to save the changes you have made, do not press the Menu/Execute switch; simply do nothing for approximately 12 seconds, and the system will return to the normal operating mode or scroll to “R” and push the menu/Execute switch and select “NO” in the “SAVE SETTINGS?” window. To change the FREQUENCY: Operate the Menu/Execute switch u ...

2.5.5 Gain/Level Changes

When you get to this menu note that the gain changes will be made as you make them but if you do not wish to save the changes you have made, scroll to “R” and push the menu/Execute switch and select “NO” in the “SAVE SETTINGS?” window or do not press the Menu/Execute switch; simply do nothing for approximately 12 seconds, and the system will return to the normal operating mode. 2.5.5.1 Upconverter Input Level To set t ...

2.5.5.2 Downconverter Gain

To set the downconverter gain, first push the Menu/Execute switch to get to the gain setting: Operate the Menu/Execute switch until you get to the menu item you want to change see Figure 2.4 for the sequence of menu options. The following display is for changing the downconverter gain. This is an important setting to optimize spurious and should be made as accurately as possible to provide an output in the -10 to 0 dBm level ran ...

ON POWER UP

NORMAL DISPLAY PUSHING MENU/EXECUTE SEQUENCE REV 1.00 U F = 1450 G = +00.0 D F = 1350 G = +25.0 UP F = 1450 SCROLL <> SCROLL PUSH BUTTON REMOTE OFF INT REF UP MUTE OFF SCROLL <> SCROLL PUSH BUTTON SCROLL <> SCROLL PUSH BUTTON SCROLL <> SCROLL PUSH BUTTON SCROLL <> SCROLL PUSH BUTTON PUSH BUTTON Power Up Normal Display Menu 1 Up Frequency Menu 2 Up Input Level (Set from -40 to -10) Menu 3 Down Frequency Menu 4 Down Gain (set 0 to ...