IMPORTANT SAFETY INSTRUCTIONS

WARNING – To guard against injury, basic safety precautions should be observed, including the following. a) READ AND FOLLOW ALL SAFETY INSTRUCTIONS. b) DANGER – To avoid possible electric shock, special care should be taken since water is employed in the use of aquarium equipment. For each of the following situations, do not attempt repairs by yourself; return the appliance to an authorized service facility for service o

and Technical Information

External Aquarium Filter 2222 and 2224 Aquarium Thermofilter 2322 and 2324 Model: see type label at top of filter Thank you for buying a new external filter EHEIM professionel. It gives you optimum performance with excel- lent reliability and great effectiveness. The large container volume – combined with a balanced combination of filter media – guarantees highly effective disposal of pollutants. Pleas

Flip all four EZ clips open and push upwards. With the help of the two recessed lid handles,

the pump head of the filter can be easily lifted off. (2) Remove fine filter pad and take out each media container by grabbing the retractable handles and pulling upwards. (3) Fill the filter media containers with EHEIM filter media to achieve best results. Fill the bottom container with EHEIM MECH, but leave just enough space so that the blue filt

EHEIM 2222 Place the pump head onto the filter canister so that the input connector of the pump head is

lined up with the input guide of the media containers. Close all four EZ clips. (9) Attention: Before the integrated double tap connector is inserted into the pump head of the filter, examine both o-rings for damage and correct fitting. Lightly grease the o-rings with Va- seline to help installation. (10) Insert the integrated double tap connector with the lock

EHEIM 2222 (21) Tip: Alternatively use the EHEIM Universal Installation Kit 1 (order no. 4004300, diam. 12 mm)

(22) or the EHEIM suction device (order no. 4003540). The canister will then automatically fill up with water. Reconnect the hose to the spray bar. (23) Tip: The water flow from the pump can be controlled by using the tap only on the pressure side (OUT). Attention: Never reduce the pump output by closing the tap on the suction side (IN). (24) Once again chec

(31) Open all EZ clips and remove the pump head from the canister.

(32) In order to clean the pump chamber, turn the pump head upside down and open the pump cover by turning it anti-clockwise. (33) Then remove the pump cover, impeller and shaft. (34) Thoroughly clean pump parts, impeller chamber and cooling channel with EHEIM cleaning set (order no. 4009580). Carefully rinse off shaft (danger of breakage!), then put impeller back to- gether again and in

EHEIM Aquariums Owners Instructions: