Datalogic Matrix 120 Operation & User’s Manual
Read Online
Read the Datalogic Matrix 120 Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
Skip to content
Manuals+
User Manuals Simplified.
DATALOGIC Matrix 120 User Guide
Home » DATALOGIC » DATALOGIC Matrix 120 User Guide
Contents [ hide
1 DATALOGIC Matrix 120
2 INSTALLATION
PROCEDURE
3 Mounting
4 Electrical Connections
4.1 I/O Connections
5 Connector Pinouts
6 CONFIGURATION
6.1 Installing DL.CODE
7 TECHNICAL FEATURES
8 PATENTS
9 LASER SAFETY
10 File Downloads
11 References
12 Related Manuals
DATALOGIC Matrix 120
Datalogic provides several services as well as technical support through its website. Log on to www.datalogic.com.
For quick access, from the home page click on the search icon , and type in the name of the product you’re looking
for. This allows you access to download Data Sheets, Manuals, Software & Utilities, and Drawings. Hover over the
Support & Service menu for access to Services and Technical Support.
INSTALLATION PROCEDURE
1. Using a 2.5 mm hex key, set the Focus Adjustment Screw to one of the three pre-calibrated distances according
to your application.
2. Physically mount the Matrix 120 reader.
3. Make the necessary electrical connections.
4. Configure the reader using the X-PRESS interface (AIM, SETUP, LEARN and TEST for simple configuration) or
the DL.CODE software configuration program (complete configuration).
HMI X-PRESS™ INTERFACE
In normal operating mode the colors and meaning of the five LEDs are illustrated in the following table:
READY (green)
indicates the device is ready to operate.
GOOD (green)
confirms successful reading.
TRIGGER (yellow)
indicates the status of the reading phase.
COM (yellow)
indicates active communication on main serial port.
STATUS (red)
indicates a NO READ result.
During the reader startup (reset or restart phase), all the LEDs blink for one second. The single push button gives
immediate access to the following relevant functions:
Test Mode with bar graph visualization to check
static reading performance.
Focus (Aim) turns on the laser LED to aim the reader
at the target. The target should be placed 8 mm to
the left and centered vertically with respect to the
aiming pattern (cross).
Setup to self-optimize and auto-configure photometry
parameters.
Learn to self-detect and auto-configure for reading
an unknown barcode (by type and length). Only one
symbology type can be saved using this method.
Performing Autolearn on a second symbology will
overwrite the first one.
1. HMI X-PRESS™ Interface PRESS
2. Power On LED
3. Ethernet Connection LED
4. Mounting Holes (4)
5. Aiming System Laser Source
6. Lens
7. Good Read LED Green
8. Internal Illuminators
9. Focus Adjustment Screw
10. Ethernet Cable
11. Power-serial- I/O Cable
Mounting
1. To mount the Matrix 120, use the mounting bracket to obtain themost suitable position for the reader. Common
mounting configurations are shown in the figures below.
Electrical Connections
I/O Using CAB-1011 to CBX:
CAUTION: When Matrix 120 is connected to the CBX connection box through CAB-1011, Inputs and Outputs
become opto-isolated and maintain the polarity significance of the CBX signals. To function correctly, they all require
setting the respective Line Type configuration parameters to NPN. The hardware connection to the CBX can be
either NPN or PNP
The electrical features of both inputs at the CBX are:
VAB = 30 Vdc max.
IIN = 12 mA (CAB-1011) + 12 mA (CBX) max.
The following connections refer to Datalogic sensors.
I/O Using CAB-1051:
CAUTION: If output devices are powered externally (separate from Matrix 120 power), it is always advised to
maintain the same voltage levels used for the Matrix 120 device
Power – Serial – IO
Ethernet
Pin 1 = TX+
4
3 1
2
Pin 2 = RX+
Pin 3 = TX-
Pin 4 = RX-
Use Cat 5e or superior
cables.
17-pin
Name
Function
9**
O1
Output 1 (referenced to GND)
8**
O2
Output 2 (referenced to GND)
6
IN1
External Trigger (referenced to GND)
13
IN2
Input Signal 2 (referenced to GND)
7
USB+
USB Data + (only for USB models)
15
USB-
USB Data – (only for USB models)
1
Vdc
Power Supply Input Voltage +
2
GND
Power Supply Input Voltage –
5
–
Reserved
3, 4, 14, 16 NC
not connected
Shield
Cable shield connected to chassis and 17-pin connector shell
RS232 Main Serial Interface RS422 FD
17
TX
TX+
referenced to GND; Outputs become opto-isolated and polarity sensitive when connected through the CBX
connection box. See Reference Manual for connectionmdetails.
*** do not leave floating. See Reference Manual for connection details.
Focus and Positioning
The Matrix 120 models are factory calibrated at three focus positions (45, 70 and 125 mm for WVGA models; 45, 80
and 125 mm for MP models). Using a 2.5 mm Hex key (Allen wrench), rotate the Focus
Adjustment Screw at the back of the reader to one of these three positions for your application.
CAUTION: Do not rotate the Focus Adjustment Screw beyond the focus scale limits otherwise damage can occur to
the focus mechanism.
The following tables show the reading ranges at the three focus positions for Code 128 (1D) and Data Matrix (2D) 10
mil resolution codes:
WVGA Models (Matrix 120 210-xxx)
Focus
Position
Horizontal
FOV
Reading Range (DOF)
1D
2D
45
38 mm
1.5 in
30 – 80 mm
1.2 – 3.1 in
25 – 70 mm
1.0 – 2.8 in
70
56 mm
2.2 in
60 – 125 mm
2.4 – 4.9 in
45 – 100 mm
1.8 – 3.9 in
125
95 mm
3.7 in
95 – 155 mm
3.7 – 6.1 in
65 – 120 mm
2.6 – 4.7 in
MP Models (Matrix 120 310-xxx)
Focus
Position
Horizontal
FOV
Reading Range (DOF)
1D
2D
45
40 mm
1.6 in
30 – 90 mm
1.2 – 3.5 in
30 – 80 mm
1.2 – 3.1 in
80
67 mm
2.6 in
60 – 130 mm
2.4 – 5.1 in
60 – 125 mm
2.4 – 4.9 in
125
100 mm
3.9 in
100 – 190 mm
3.9 – 7.5 in
110 – 165 mm
4.3 – 6.5 in
WA Models without Polarizer (Matrix 120 311-xx0)
Focus
Position
Horizontal
FOV
Reading Range (DOF)
1D
2D
45
52 mm
2.0 in
25 – 90 mm
1.0 – 3.5 in
30 – 65 mm
1.2 – 2.6 in
80
86 mm
3.4 in
65 – 145 mm
2.6 – 5.7 in
55 – 105 mm
2.2 – 4.1 in
125
130 mm
5.1 in
105 – 180 mm
4.1 – 7.1 in
80 – 125 mm
3.1 – 4.9 in
The focus range is continuous to provide fine-tuning for your application
CONFIGURATION
1. On the PC that will be used for configuration, (running Windows 7, 8, or 10), download the DL.CODE mini-DVD
.zip file. Extract the files maintaining the folder structure and run the start.hta file to access the installation pop-
up. Click on the Install DL.CODE link to run the installation program and follow the installation procedure.
2. When the installation is complete the DL.CODE entry is created in the Start>Programs bar under “Datalogic” as
well as a desktop icon. Double-click the desktop icon to run it.
3. Follow the Matrix 120 Reference Manual to configure:
Image lighting and code definition (Automatic or Advanced Setup)
Reading Phase and Communication Channel Selection
Data Collection Type
Data Formatting
Digital Output(s)
TECHNICAL FEATURES
5 to 30 Vdc
(10 to 30 Vdc with CBX)
Consumption
0.4 to 0.1 A Max.
Communication Interfaces
2400 to 115200 bit/s
Main
RS232 or RS422 FD
USB
USB 2.0 Hi-Speed
Ethernet1
10/100 Mbit/s
Inputs:
short-circuit protected
(Opto-coupled and polarity insensitive when connected
through CBX)
Outputs:
short-circuit protected
(Opto-coupled when connected through CBX)
OPTICAL FEATURES (see Reference Manual for details)
PHYSICAL FEATURES
Serial + USB
Serial + Ethernet
Dimensions mm (inch)
45.4 x 31.1 x 23.5
(1.8 x 1.2 x 1)
45.4 x 48.5 x 23.5
(1.8 x 1.9 x 1)
Weight grams (ounces)
117 (4.1) with cable
200 (7.1) with cable
Material
Aluminium
Aluminium
ENVIRONMENTAL FEATURES
Operating Temperature2
0 to 45 °C (32 to 113 °F)
Storage Temperature
-20 to 70 °C (-4 to 158 °F)
Max. Humidity
90% non-condensing
Vibration Resistance EN 60068-
2-6
14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
2 g @ 70 to 500 Hz; 2 hours on each axis
Shock Resistance EN 60068-2-
27
30g; 11 ms;
3 shocks up and 3 down on each axis
Bump Resistance EN 60068-2-
29
30g; 6 ms;
5000 bumps up and 5000 down on each axis
Protection Class EN 60529
IP65
Power; Ready, Good, Trigger, Com, Status; Ethernet
Network; Green Spot; (see Reference Manual for other
LEDs)
Other
X-PRESS™ Keypad Button (configurable via DL.CODE™),
Beeper
1 the embedded Ethernet interface supports application protocols: TCP/IP, EtherNet/IP, PROFINET-IO, Modbus
TCP.
2 high ambient temperature applications should use metal mounting bracket for heat dissipation.
Readable Code Symbologies
1D and stacked
2D
POSTAL
Digimarc
Barcode
·PDF417 ·
Codabar Standard
and ·Code 93 Micro
PDF417
Pharmacode
· Code 128
· EAN-8/13 -
(GS1-128)
UPC-A/E · Code
39
(including
(Standard and
Addon 2 and
Full ASCII)
Addon 5)
Code 32 ·
GS1 DataBar
· MSI Family
·Standard 2 of 5 ·
Composite
·Matrix 2 of 5
Symbologies
·Interleaved 2 of 5
· Data
Matrix ECC
200
(Standard,
GS1 and
Direct
Marking)
· QR
Code
(Standard
and Direct
Marking)
· Micro
QR Code
·
MAXICODE
· Aztec
Code
·
Australia
Post
· Royal
Mail 4
State
Customer
· Kix
Code
· Japan
Post
·
PLANET
·
POSTNET
·
POSTNET
(+BB)
·
Intelligent
Mail
·
Swedish
Post
DWCODE™
*
Operating Mode CONTINUOUS, ONE SHOT, PHASE
MODE
Configuration
Methods
X-PRESS™ Human Machine Interface
Windows-based SW (DL.CODE™) via
Ethernet or Serial Interface
Host Mode Programming sequences
sent over Serial or Ethernet TCP
interfaces
Parameter
Storage
Permanent memory (Flash)
PATENTS
See www.patents.datalogic.com for patent list.
This product is covered by one or more of the following patents:
Matrix 120™
Design patents: EP003042845; EP003074079
Utility patents: EP0996284B1; EP0999514B1; EP1014292B1; EP1128315B1; EP1172756B1; EP1396811B1;
EP1413971B1; EP1804089B1; EP2315156B1; EP2517148B1; EP2649555B1; JP4435343B2; JP4571258B2;
JP5192390B2; US6512218; US6616039; US6808114, US6877664; US6997385; US7053954; US7387246;
US8058600; US8113430; US8368000; US8888003; US8915443; US9268982; US9430689; ZL200680050007.8.
Only connect Ethernet and dataport connections to a network which has routing only within the plant or building and
no routing outside the plant or building.
EMC COMPLIANCE
In order to meet the EMC requirements:
connect reader chassis to the plant earth ground by means of a flat copper braid shorter than 100 mm;
connect pin “Earth” of the CBX connection box to a good Earth Ground;
POWER SUPPLY
This product is intended to be installed by Qualified Personnel only. This product is intended to be connected to a UL
Listed Computer (LPS or “Class 2”) which supplies power directly to the reader or a UL Listed Direct Plug-in Power
Unit marked LPS or “Class 2”.
EAC COMPLIANCE
Customs Union:
The CU Conformity certification has been achieved; this allows the
Product to bear the Eurasian mark of conformity.
LED SAFETY
LED emission according to EN 62471
LASER SAFETY
All Matrix 120s contain one aiming Laser source used to position the reader.
These products conform to the applicable requirements of IEC 60825-1 and comply with 21 CFR 1040.10 except for
deviations pursuant to Laser Notice N° 50, date June 24, 2007. This product is classified as a Class 1M laser product
according to IEC 60825-1 regulations.
WARNING: Use of controls or adjustments or performance of procedures other than those specified herein may
result in exposure to hazardous visible laser light.
LASER RADIATION DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS CLASS 1M LASER PRODUCT
Disconnect the power supply when opening the device during
maintenance or installation to avoid exposure to hazardous laser light. The laser beam can be switched on or off
through a software command.
CE COMPLIANCE
CE marking states the compliance of the product with essential requirements listed in the applicable European
directive. Since the directives and applicable standards are subject to continuous updates, and since Datalogic
promptly adopts these updates, therefore the EU declaration of conformity is a living document. The EU declaration
of conformity is available for competent authorities and customers through Datalogic commercial reference contacts.
Since April 20th, 2016 the main European directives applicable to Datalogic products require inclusion of an
adequate analysis and assessment of the risk(s). This evaluation was carried out in relation to the applicable points
of the standards listed in the Declaration of Conformity. Datalogic products are mainly designed for integration
purposes into more complex systems. For this reason, it is under the responsibility of the system integrator to do a
new risk assessment regarding the final installation.
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the
user may be required to take adequate measures.
FCC COMPLIANCE
Modifications or changes to this equipment without the expressed written approval of Datalogic could void the
authority to use the equipment. This device complies with PART 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
LEGAL NOTICES
© 2016 – 2019 Datalogic S.p.A. and/or its affiliates � ALL RIGHTS RESERVED. � Without limiting the rights under
copyright, no part of this documentation may be reproduced, stored in or introduced into a retrieval system, or
transmitted in any form or by any means, or for any purpose, without the express written permission of Datalogic
S.p.A. and/or its affiliates.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.
and the E.U. Matrix 120, DL.CODE and X-PRESS are trademarks of Datalogic S.p.A. and/or its affiliates. Digimarc®
and DWCODE™ are trademarks of Digimarc Corporation. All other trademarks and brands are property of their
respective owners.
Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or
consequential damages resulting from the use of this material.
File Downloads
User Guide
Matrix 120
Download [optimized]
Download
References
datalogic.com/
patents.datalogic.com
X-PRESS™ Trademark
CODE™ Trademark
DWCODE™ Trademark
120™ Trademark
Digimarc® Trademark
Related Manuals
1. Fiilex Matrix II Tunable White User Guide Fiilex Matrix II Tunable White User Guide What’s In The...
2. BLACK BIRD 4K 4×4 HDMI Matrix with HDBaseT Out User Guide BLACK BIRD 4K 4×4 HDMI Matrix
INTRODUCTION This Blackbird™ device...
3. BLACK BIRD 4K Pro 4×4 HDMI True Matrix User Guide 4K Pro 4×4 HDMI® True Matrix PN 15378 < RS-232...
4. BLACK BIRD 4K 4×4 HDBaseT Matrix with 3 Receivers User Guide BLACK BIRD 4K 4×4 HDBaseT Matrix with 3
Receivers User...
5. JBL Tune 120 TWS Earbuds User Manual Quick Start Guide UNE120TWS WHAT’S IN THE BOX How to...
6. LAB GRUPPEN 120 Watt Commercial Amplifier Energy Star Certification User Manual LAB GRUPPEN 120
Watt Commercial Amplifier Energy Star Certification User...